DS300f G2 Series User Manual
135
a
ccePtInG
an
I
ncomPlete
a
rray
(clu)
This condition is the result of a missing physical drive. See “Incomplete Array” on page 215 before you use this
function.
To accept an incomplete array:
1. From the Main Menu, highlight
Disk Array Management
and press
Enter
.
2. Highlight the disk array you want and press
Enter
.
3. Highlight
Accept Incomplete Array
and press
Enter
.
e
nablInG
m
eDIa
P
atrol
, PDm,
anD
P
ower
m
anaGement
on
a
D
ISk
a
rray
(clu)
Media Patrol checks the magnetic media on physical drives. Predictive Data Migration (PDM) migrates data from
the suspect physical drive to a spare drive
before
the physical drive fails. Power Management parks the heads,
spins down, and stops rotation after a set period of time to reduce power consumption.
Media Patrol, PDM, and Power Management are enabled by default. Enabled is the recommended setting for
both features.
To enable Media Patrol, PDM, and Power Management on a disk array:
1. From the Main Menu, highlight
Disk Array Management
and press
Enter
.
2. Highlight the disk array you want and press
Enter
.
3. Highlight
Media Patrol
and press the spacebar to toggle between
Enable
and
Disable
.
4. Highlight
PDM
and press the spacebar to toggle between
Enable
and
Disable
.
5. Highlight
Power Management
and press the spacebar to toggle between
Enable
and
Disable
.
6. Press
Control-A
to save your settings.
See "Running PDM on a Disk Array (CLU)" on page 136 and "Making Background Activity Settings (CLU)" on
For Power Management settings, see "Making Controller Settings (CLU)" on page 124.
P
reParInG
the
D
ISk
a
rray
for
t
ranSPort
(clu)
To run the Transport function on a disk array:
1. From the Main Menu, highlight
Disk Array Management
and press
Enter
.
2. Highlight the disk array you want and press
Enter
.
3. Highlight
Transport
and press
Enter
.
4.
Press Y to confirm.
r
ebuIlDInG
a
D
ISk
a
rray
(clu)
Before you can rebuild, you must have a replacement or target physical drive of adequate capacity for your disk
array.
To rebuild a disk array:
1. From the Main Menu, highlight
Disk Array Management
and press
Enter
.
2. Highlight the disk array you want and press
Enter
.
3. Highlight
Background Activities
and press
Enter
.
4. Highlight
Rebuild
and press
Enter
.
Default source and target drives are shown with possible alternative choices.
5. To choose different drive, highlight the drive, press the backspace key to remove the current number, then
type a new number.
6. Highlight
Start
and press
Enter
.
For rebuild rate, see "Making Background Activity Settings (CLU)" on page 154.
r
unnInG
m
eDIa
P
atrol
on
a
D
ISk
a
rray
(clu)
Media Patrol is a routine maintenance procedure that checks the magnetic media on each disk drive. If Media
Patrol encounters a critical error, it triggers PDM if PDM is enabled on the disk array.
See
"Enabling Media Patrol, PDM, and Power Management on a Disk Array (CLU)" on page 135.
For Media Patrol rate, see "Making Background Activity Settings (CLU)" on page 154.