Chapter 3
–
AMI BIOS Setup
59
Fan
les
s E
mb
ed
ded
Bo
x
PC
BO
XE
R-
66
42
-C
ML
3.5.1
System Agent (SA) Configuration
Options Summary
SA GV
Disabled
Fixed Low
Fixed High
Enabled
Optimal Default, Failsafe Default
System Agent Geyserville.
Fixed Low/High: SA GV disabled, MRC only runs tasks from Low or High point. SA GV
will be disabled on DT/Halo CPUs, regardless of this setting.
PM Support
Enabled
Optimal Default, Failsafe Default
Disabled
Enable/Disable PM Support
RC6(Render Standby)
Disabled
Optimal Default, Failsafe Default
Enabled
Check to enable render standby support.
DVMT Total Gfx Mem
128M
256M
Optimal Default, Failsafe Default
MAX
Select DVMT5.0 Total Graphic Memory size used by the Internal Graphics Device.
Содержание AAEON BOXER-6642-CML
Страница 1: ...Last Updated April 7 2021 BOXER 6642 CML Fanless Embedded Box PC User s Manual 1st Ed ...
Страница 15: ...Fanless Embedded Box PC BOXER 6642 CML Chapter 1 Chapter 1 Product Specifications ...
Страница 18: ...Fanless Embedded Box PC BOXER 6642 CML Chapter 2 Chapter 2 Hardware Information ...
Страница 19: ...Chapter 2 Hardware Information 5 Fanless Embedded Box PC BOXER 6642 CML 2 1 Dimensions System ...
Страница 20: ...Chapter 2 Hardware Information 6 Fanless Embedded Box PC BOXER 6642 CML Board Dimensions ...
Страница 21: ...Chapter 2 Hardware Information 7 Fanless Embedded Box PC BOXER 6642 CML 2 2 Jumpers and Connectors ...
Страница 49: ...Fanless Embedded Box PC BOXER 6642 CML Chapter 3 Chapter 3 AMI BIOS Setup ...
Страница 52: ...Chapter 3 AMI BIOS Setup 38 Fanless Embedded Box PC BOXER 6642 CML 3 3 Setup Submenu Main ...
Страница 53: ...Chapter 3 AMI BIOS Setup 39 Fanless Embedded Box PC BOXER 6642 CML 3 4 Setup Submenu Advanced ...
Страница 64: ...Chapter 3 AMI BIOS Setup 50 Fanless Embedded Box PC BOXER 6642 CML 3 4 7 Hardware Monitor ...
Страница 72: ...Chapter 3 AMI BIOS Setup 58 Fanless Embedded Box PC BOXER 6642 CML 3 5 Setup Submenu Chipset ...
Страница 82: ...Chapter 3 AMI BIOS Setup 68 Fanless Embedded Box PC BOXER 6642 CML 3 8 Setup Submenu Save Exit ...
Страница 83: ...Fanless Embedded Box PC BOXER 6642 CML Chapter 4 Chapter 4 Drivers Installation ...
Страница 86: ...Fanless Embedded Box PC BOXER 6642 CML Appendix A Appendix A Watchdog Timer Programming ...
Страница 92: ...Fanless Embedded Box PC BOXER 6642 CML Appendix B Appendix B I O Information ...
Страница 93: ...Appendix B I O Information 79 Fanless Embedded Box PC BOXER 6642 CML B 1 I O Address Map ...
Страница 94: ...Appendix B I O Information 80 Fanless Embedded Box PC BOXER 6642 CML ...
Страница 95: ...Appendix B I O Information 81 Fanless Embedded Box PC BOXER 6642 CML B 2 IRQ Mapping Chart ...
Страница 96: ...Appendix B I O Information 82 Fanless Embedded Box PC BOXER 6642 CML B 3 Memory Address Map ...
Страница 97: ...Appendix B I O Information 83 Fanless Embedded Box PC BOXER 6642 CML ...
Страница 98: ...Fanless Embedded Box PC BOXER 6642 CML Appendix C Appendix C Digital I O Ports ...
Страница 102: ...Appendix C Digital I O Information 88 Fanless Embedded Box PC BOXER 6642 CML ...
Страница 109: ...Fanless Embedded Box PC BOXER 6642 CML Appendix D Appendix D Glue Removal Procedure ...