TrojanTwo-Compact User Guide v3.8
Page | 87
3.
Unscrew the cap of the waste ink bottle carefully and dispose the waste ink.
14.2
Replacing the wiper roller
The wiper roller (microfiber roller) is a consumable and a wear and tear part, thus needs to be replaced
when it wears down.
It is advised to change the wiper roller at least after every 6 months.
Signs that the wiper roller might needs replacement:
If surface of the wiper roller looks shiny and not ‘fluffy’ anymore, then wiper roller is worn down
and needs replacement.
If printhead wiping routines (like wipe printhead or light/medium/heavy clean) do not improve
print quality and fine streak(s) remain on the printouts after the routines has been run multiple
times already.
If ink puddles remain on the printhead surface after a wipe printhead maintenance.
Part number:
Part description:
10003356
T2 Wiper Roller Gen 2 (Micro Fiber Roller)
Required equipment:
WARNING!
The ink might be considered as Hazardous Waste in some countries. Make sure you fill
the waste ink from the bottle into a separated tank and disposal is done according to
the local regulations!
However in other countries, the Trojan ink is not considered as hazardous waste and
can be disposed down the drain.
Material Safety Data Sheets (MSDS) for the Trojan ink can be downloaded from
Trojanlabel extranet or acquired from the local partners.
Distilled Water
Rubber gloves
Lint-Free cloth