Upon power-up the Sensor requires approximately 20 seconds to produce a useable
image. During this time period a video test pattern is displayed for approximately 5
seconds followed by the message “OK”. After approximately 20 seconds the display will
blank momentarily for a NUC cycle and a useable image then appears. The image
generated is a monochrome (i.e., black and white) image. The
hotter
an object is the
whiter
it appears on the display. This is known as “white hot” polarity.
The display should be adjusted for optimum brightness and contrast, and readjusted
only during relatively benign phases of flight or periods of low workload. The image
then should be cross checked in a manner similar to other cockpit displays, using short
dwell times and appropriate cockpit priorities.
To optimize the IR image the EVS system periodically recalibrates itself. The
recalibration process is known as “Non-Uniformity Correction” (NUC). NUC can be
observed on the display as a momentary image interruption with “CAL” displayed. The
shutter closes for approximately one second during the NUC process, which happens
every four minutes or when manually activated, if an appropriate switch is installed in
the cockpit.
5.
MAINTENANCE
Both the Sensor and Power Supply may be viewed as sealed “black boxes” where no
field maintenance, repair, or upgrade is performed. All such activities are conducted at
Max-Viz, Inc.
To ensure your system will be covered under warranty, fill out and submit the Max-Viz
Warranty Registration form located at the end of this manual, at the time of system
installation.
If you have difficulties operating the system, first contact your authorized Max-Viz
dealer for technical support. They will contact the type certificate holder, if it is a
certified installation. The type certificate holder will contact Max-Viz as necessary. If it is
not a certified installation, the dealer will contact Max-Viz.
If it is determined the Max-Viz 1500 must be returned for service or maintenance, Max-
Viz will issue a Return Material Authorization (RMA). Fill out Max-Viz Customer
Service Request Form located at the end of this manual and submit it to receive a RMA.
After receipt of the RMA, return the system to the address in Section 7.
A copy of the Customer Service Request Form (RMA) and Warranty Registration Form
are included at the end of this manual, but are also available at
Содержание Max-Viz 1500
Страница 1: ...Astronics Max Viz Max Viz 1500 3091 00019 Rev M Information Manual Max Viz 1500 Enhanced Vision System...
Страница 17: ...Astronics Max Viz Max Viz 1500 3091 00019 Rev M...
Страница 18: ...Astronics Max Viz Max Viz 1500 3091 00019 Rev M...
Страница 19: ...Astronics Max Viz Max Viz 1500 3091 00019 Rev M...
Страница 20: ...Astronics Max Viz Max Viz 1500 3091 00019 Rev M...
Страница 21: ...Astronics Max Viz Max Viz 1500 3091 00019 Rev M...
Страница 22: ...Astronics Max Viz Max Viz 1500 3091 00019 Rev M...