Astronergy ASM6610 Series Скачать руководство пользователя страница 3

3

Make sure no other system components impair the
mechanical or electrical function of the solar modules.
• Only work in dry conditions with dry solar modules and dry, 

electrical isolated tools.

• Do not drill any holes into the module frame or the glass 

surface and do not carrying out any welding work on or in

• the direct vicinity of the solar module.
• To avoid burns do not touch solar modules under load 

without wearing gloves.

• Never touch solar modules with cracked or broken cover 

glasses or damaged back sheets without wearing gloves.

• Comply with the applicable occupational health and safety 

regulations (e.g. regarding protective clothing).

• Carry out the entire installation in the presence of a second 

person so that assistance can be provided in case of an 
accident.

• Keep a copy of this installation manual in the immediate 

vicinity of the system for the whole lifetime of the system.

• Make sure that nobody will kneeling, standing or walking 

on the modules and that no other punctual loads happened  

to the front- or backside of the solar module. Point loads 

can lead to micro cracks, thus risk of yieldloss and potential 

electrical hazard will increase.

3. Installation

3.1 General installation instructions

Make sure that all locally applicable standards, construction
regulations and accident prevention regulations are complied
with.
• Select an installation location with the maximum sunlight 

at all times of the year. Avoid shaded areas. Shading all year 
round of larger areas or single modules or cells is reducing 
annual yield and potentially reducing bypass-diodes 
lifetime.

• In northern latitudes, orient the solar modules to the south.
• Make sure a minimum module inclination of 5°, otherwise 

self cleaning effect will be severely limited, thus parts of 
cells can be shaded and will reduce yield significantly. 

• Always mount the solar modules with the same orientation 

and tilt angle. Otherwise you will have to use a separate 
inverter or separate DC input.

• Maintain an adequate distance between adjacent solar 

modules to allow for expansion in case of changing thermal 
conditions.

Figure 1: Clamping locations according to 

released loading levels for 40mm frame

Figure 2:  Module drawing for 40mm frame

 

6000 Pa
4200 Pa
2400 Pa

247

115

100

200

50

ø 5.2

989

ø 5.2

260

1134

1654

260

ø 5.2

ø 5.2