AstroAI JC-90-E Скачать руководство пользователя страница 1

V1.0

Beverage Cooler 
User Manual

Содержание JC-90-E

Страница 1: ...V1 0 Beverage Cooler User Manual...

Страница 2: ...damage to the product Please keep this manual for future reference Thank you for purchasing the AstroAI 90L Beverage Cooler This is a super large capacity beverage cooler that can be plugged in to a s...

Страница 3: ...be repaired Before use the beverage cooler must be installed correctly in accordance with the instructions USE SAFELY When installing make sure there is enough ventilation space around the cooler Do...

Страница 4: ...trol Panel 4 Metal Shelf 5 Gasket 6 Bottom Hinge 7 1 Screw Panel Hole Plug 9 Hinge Cover 10 Screw 11 Top Hinge 12 Compressor 13 Leveling Feet 8 10 ACCESSORIES AND STRUCTURE DIAGRAM 2 3 4 5 7 8 9 11 12...

Страница 5: ...3 Temperature Display Temperature Down 4 CONTROL PANEL DIAGRAM SIZE DIAGRAM 1 2 3 4 1 2 3 8 9 3 76cm 29 9in 47 6cm 18 7in 1 44cm 17 3in 2 37cm 14 6in 4 13 5cm 5 3in 5 20cm 7 9in 6 35cm 13 8in 7 69cm 2...

Страница 6: ...izontal position a Use the leveling feet that are located on the front foot of cooler to adjust b Rotate the leveling feet clockwise to lower the height of the cooler c Or rotate the leveling feet ant...

Страница 7: ...s not damaged the door can be closed Warning Do not put the cooler upside down diagonally or irregularly If your cooler tilts for any reason please stand it still for 24 hours before plugging it in DO...

Страница 8: ...remove the bottom hinge by removing the screws with a Phillips head screwdriver Put all parts aside Rotate the door buckle on the bottom hinge that has just been removed and rotate it into the other h...

Страница 9: ...w panel hole plug into the screw holes MAINTENANCE To avoid electric shocks always unplug the cooler before cleaning or defrosting CLEANING Overall cleaning prepare a certain amount of baking soda sol...

Страница 10: ...d due to thunderstorms or other reasons In the event of a power failure unplug the power cord from the AC outlet After the power is restored plug the power cord back into the AC power outlet Note If n...

Страница 11: ...cuit breaker has tripped causing the AC outlet to lose power Problem Possible Causes Ensure the cooler is plugged in and the power outlet has power Replace the broken home fuse or reset the breaker So...

Страница 12: ...se or increase the ambient temperature Do not store large quantities of liquids at one time Close the door tightly and do not open it too often or for too long The door does not close properly The Coo...

Страница 13: ...m temperature distribution and save energy 2 YEAR LIMITED WARRANTY FROM ASTROAI Each AstroAI 90L Beverage Cooler will be free from defects in material and workmanship This warranty does not cover dama...

Страница 14: ...Web astroai com E mail support astroai com...