●  When servicing the Meter, use only the same model number or identical electrical 

specifications replacement parts. 

●  The internal circuit of the Meter shall not be altered at will to avoid damage of the Meter 

and any accident. 

●  Clean using a soft cloth and mild detergent for the surface of the Meter. Do not use 

abrasive materials or solvents to prevent the surface of the Meter from corrosion and 
damage. 

●  Turn the Meter off when not in use and take out the battery when it is not going to be 

used for an extended period of time. Regularly check the battery as it may leak when it 
has not been used for some time. Replace the battery as soon as leaking appears. A 
leaking battery will damage the Meter. 

 
 
 

ELECTRICAL SYMBOLS 

 

 

AC (Alternating Current) 

 

Low Battery 

 

DC (Direct Current) 

 

Diode 

 

AC and DC 

 

Fuse 

 

Earth Ground 

 

Continuity Test 

 

Double Insulated 

 

Warning 

AUTO 

Auto Range 

 

Dangerous Voltage may be present 

 

Complies with EU Directives 

APO 

Auto Power Off 

 

Battery Capacity 

 

Relative Test 

 

Data Hold 

 

 
 
 
 
 
 
 
 
 
 
 

Содержание DT132A

Страница 1: ...if all or part of the exterior casing is removed Look for cracks or missing plastic Pay special attention to the insulation around the connectors Inspect the test leads for damaged insulation or expos...

Страница 2: ...and damage Turn the Meter off when not in use and take out the battery when it is not going to be used for an extended period of time Regularly check the battery as it may leak when it has not been u...

Страница 3: ...al Polarity Indication displayed Overload Indication OL displayed Low Battery Indication Yes Operating Environment 32 F 104 F 0 C 40 C 80 RH Storage Temperature 14 F 122 F 10 C 50 C 85 RH Power 3 x 1...

Страница 4: ...de when measuring voltage current resistance or capacitance When the meter is in auto range mode AUTO is displayed on the screen To enter or exit manual range mode press the RANGE button When entering...

Страница 5: ...maximum and minimum values will be cleared after cleared when the test function changes or the meter is turned off 6 Relative Test Press this button to store the current reading and resets the display...

Страница 6: ...t Impedance 10M Overload Protection 600V DC or 600V AC rms 200mV range 250V DC AC rms Max Input Voltage 600V DC AC Voltage Auto Ranging Range Resolution Accuracy 400mV 1mV 1 2 of rdg 5 dgts 4V 1mV 1 0...

Страница 7: ...ed for standard configuration DC Current Range Resolution Accuracy 400 A 0 1 A 1 2 of rdg 8dgts 4000 A 1 A 40m A 10 A 400m A 100 A 4A 1mA 10A 10mA Overload Protection A and mA ranges F0 5A 600V fuse 4...

Страница 8: ...l 200mA A Terminal 10A For measurements 5A only measure in durations less than 10 seconds in intervals greater than 15 minutes Voltage Drop 400 A 40mA and 4A ranges 40mV 4000 A 400mA and 10A ranges 40...

Страница 9: ...it voltage about 0 5V Overload Protection 250V DC AC rms For continuity test When the resistance is between 50 and 100 the buzzer may sound or may not sound When the resistance is more than 100 the bu...

Страница 10: ...d 10A connect the red test lead to the 10A jack instead 2 Set the range switch to desired A mA or A range If the current magnitude to be measured is not known beforehand set the ranges switch to the h...

Страница 11: ...ead to the anode of the diode to be tested and the black test lead to the cathode 5 The meter will show the approximate forward voltage of the diode If the connections are reversed OL will be shown on...

Страница 12: ...he specified ratings Then reinstall the battery cover and lock the cover DISPOSAL OF THIS ARTICLE If you at some point intend to dispose of this article please keep in mind that many of its components...

Отзывы: