5-21-15 TI214-94-1 

 

CAUTION: 

 

VERIFY THAT THE STATIONARY DIE IS 

INSTALLED CORRECTLY. IMPROPER 
INSTALLATION WILL RESULT IN DAMAGE 
TO THE TOOL OR THE DIE SET. 

3.

 

Cycle the tool to set the dies. 

 

C

RIMPING 

O

PERATION

 

1.

 

The tool must be in the fully open position. 
Insert the prepared connector through the tool 
opening and place in the cavity. For RF 
connector fittings, use the die face as a 
locational stop. For shield terminations, locate 
the crimp by eye. 

2.

 

Squeeze the handles together until the positive 
stop is reached. The tool will release and 
return to the fully open position.  

3.

 

Remove the crimped termination. 

 

D

IE 

R

EMOVAL

 

1.

 

The tool must be in the fully open position. 
Using a flat blade screw driver or suitable 
device, gently lift on the Die Retaining Plate 
and remove the Stationary Die. See Figure #4. 

 

 

 

Figure #4 

2.

 

With the tool fully closed, slide the Movable 
Die out of the tool, as shown in Figure #5. 

 

Figure # 5 

NOTE: Always remove the Stationary Die first. 

T

OOL 

C

ALIBRATION

 

1.

 

Hand pressure of 15-25 lbs. is required to 
cycle the tool with a nominal set of dies 
installed. Astro has the AT903 spring tester 
available for calibration purposes. 

2.

 

If calibration of the hand pressure is required, 
locate the adjustment screw in the Movable 
Die Nest by closing the tool. Using a flat 
blade screwdriver, rotate the screw to the right 
to decrease the pressure, to the left to increase 
the hand pressure. See figure #6. 

 

Adjustment Screw

 

 

Figure # 6 

3.

 

When hand pressure calibration is achieved, 
lock the screw in place using an appropriate 
NON-PERMANENT sealant. 

 

T

OOL 

G

AGING

 

1.

 

Astro Tool Corp. manufactures flat GO-NO 
GO pin assemblies for many of the dies used 
by the 613214 crimp tool. Contact the factory 
for your specific requirements. 

2.

 

With a die set properly installed, cycle the 
tool into the fully closed position. Insert the 
appropriate GO sized flat pin into the hex 
cavity. It shall freely enter the hex cavity. See 
figure #7. Remove the GO pin and attempt to 
insert the NO-GO pin into the hex cavity. It 
should not enter the cavity. 

 GO Pin Inserted

Into Cavity

 

Figure #7 

DO NOT CRIMP GAGE, 

TOOL DAMAGE WILL RESULT.

 