IMPORTANT:

 Vent-free gas log heaters add 

moisture to the air. Although this is benefi cial, 
installing  fi rebox in rooms without enough 
ventilation air may cause mildew to form from 
too much moisture. See 

Air for Combustion 

and Ventilation

, page 7.

IMPORTANT:

 Make sure firebox is level. 

If  fi rebox is not level, log set will not work 
properly.

Note: Your fi rebox is designed to be used in 
zero clearance installations. Wall or framing 
material can be placed against any exterior 
surface on rear, sides, top or bottom of fi rebox, 
except where standoff spacers are integrally 
attached. If standoff spacers are attached to 
fi rebox, these spacers can be placed directly 
against wall or framing materials.

Use dimensions shown for rough openings 
to create the easiest installation (see 

Built-In 

Firebox Installation

, page 11).

INSTALLATION CLEARANCES

 WARNING: Maintain the 

minimum clearances. If you can, 
provide greater clearances from 
fl oor, ceiling and adjoining wall.

Carefully follow these instructions. This will 
ensure safe installation.

Minimum Wall and Ceiling Clearances (see 
Figure 5)

A.  Clearances from side of fi replace cabinet 

to any combustible material and wall 
should follow diagram in Figure 5.

 

Example:

 The face of a mantel, bookshelf, 

etc. is made of combustible material and 
protrudes 3 

1

/

2

" from wall. This combus-

tible material must be 4" from side of 
fi replace cabinet (see Figure 5).

B.  Clearances from top of fi rebox opening to 

ceiling should not be less than 42".

C. When fi rebox is installed on carpeting or 

other combustible material, other than 
wood fl ooring, fi rebox should be installed 
on a metal or wood panel extending full 
width and depth of enclosure.

D.  Clearances from bottom of fi rebox to fl oor 

is 0".

INSTALLATION

Continued

Figure 5 - Minimum Clearance for 

Combustible to Wall 

*Minimum 16" from Side Wall 

*

These  fi reboxes can be installed as free-
standing units against a wall with approved, 
optional cabinet mantels or as a built-in unit. 
Clearances are the same for either installa-
tion method.

 CAUTION: Do not install fi re-

box directly on carpet or vinyl.

Example

Mantel Clearances for Built-In Installation

If placing custom mantel above built-in fi rebox, 
you must meet minimum allowable clearance 
between mantel shelf and top of fi rebox open-
ing shown in Figure 6, page 11. These are 
minimum allowable mantel clearances for a 
safe installation. Use larger clearances wher-
ever possible to minimize heating of objects 
and materials placed on mantel.

 CAUTION: Do not allow 

vent-free gas log heater to 
touch or extend beyond fi re-
place screen.

NOTICE: Surface temperatures 
of adjacent walls and mantels 
become hot during operation. 
Walls and mantels above fi re-
box may become hot to the 
touch. If installed properly, 
these temperatures meet the 
requirement of the national 
product standard. Follow all 
minimum clearances shown in 
this manual.

Содержание Valiant32ZP2

Страница 1: ...G FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immedia...

Страница 2: ...s WARNING Do not use a blower insert heat exchanger insertorotheraccessorynotap proved for use with this firebox IMPORTANT Read this owner s manualcarefullyandcompletely before trying to assemble op erate or service this fireplace Improper use of this fireplace can cause serious injury or death from burns fire explo sion electricalshockandcarbon monoxide poisoning DANGER Carbonmonoxide poisoning m...

Страница 3: ...hen they are in the same room with the ap pliance 1 Do not use this firebox as a wood burning fireplace Use only decorative unvented room heaters log sets 2 Do not add extra logs or ornaments such as pine cones vermiculite or rock wool Using these added items can cause sooting 3 Use only the provided hood See Parts pages 18 and 19 The firebox canopy hood must not be modified or replaced with a can...

Страница 4: ...e models CANNOT be installed in a bedroom unless maximum Btu rating of installed vent free log set is less than 10 000 Btu hr 4 Proper air for combustion and ventilation page 7 COMMONWEALTH OF MASSACHU SETTS REQUIREMENTS These appliances are approved for installa tion in the US state of Massachusetts if the following additional requirements are met Un vented Room Heaters shall be in stalled in acc...

Страница 5: ...6 3 8 Standoffs 221 2 321 4 361 2 41 4 n g es 5 8 Figure 1 Firebox Dimensions 32 Models Right Side View Front View 32 MODELS Outside Air Kit Location Optional Left Side View with Air Kit Back View Top View Firebox Top View 9 93 4 19 3 8 16 5 8 15 8 35 8 81 8 2 7 8 85 8 Built Side Nailin Flang Square Gas Line Access Holes ...

Страница 6: ...RODUCT SPECIFICATIONS Continued Figure 2 Firebox Dimensions 36 and 42 Models 36 AND 42 MODELS Note If only one dimension is shown dimension is the same for both 36 and 42 models Firebox Top View 13 11 16 36 Models 12 3 8 42 Models 7 1 4 36 Models 9 42 Models 2 9 16 101 2 36 Models 121 2 42 Models Outside Air Kit Location Optional Left Side View with Air Kit 13 3 4 36 Models 15 5 8 42 Models 2 5 8 ...

Страница 7: ...ion you must provide additional fresh air Unusually tight construction is defined as construction where a walls and ceilings exposed to outside atmosphere have a continuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with openings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to a...

Страница 8: ...he outdoors and vents to the outdoors Example Gas water heater _________ Btu Hr Vent free heater ________ Btu Hr Total ________ Btu Hr AIR FOR COMBUSTION AND VENTILATION Continued 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________ Btu Hr maximum the space can support _________ Btu Hr actual amount of Btu Hr used Example 63 360 Btu Hr maximum the spac...

Страница 9: ...ation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent INSTALLATION Or Remove Door into Adjoining Room Option 3 Ventilation Grills Into Adjoining Room Option 2 Ventilation Grills Into Adjoining Room Option 1 12 12 Outlet Air...

Страница 10: ...ombus tible material must be 4 from side of fireplace cabinet see Figure 5 B Clearances from top of firebox opening to ceiling should not be less than 42 C When firebox is installed on carpeting or other combustible material other than wood flooring firebox should be installed on a metal or wood panel extending full width and depth of enclosure D Clearances from bottom of firebox to floor is 0 INS...

Страница 11: ...ox in front of rough open ing with back of firebox inside wall open ing IMPORTANT If installing a perimeter trim kit see instructions included with trim accessory You must install shoulder screws from trim kit now Figure 6 Minimum Mantel Clearances for Built In Installation Supplied Firebox Hood Must Be Used at All Times Wire mesh Screen Firebox Noncombustible Material May Project Off this Surface...

Страница 12: ...LATION Continued Figure 8 Attaching Firebox to Wall Studs Nailing Flanges Nails or Wood Screws WARNING Do not allow any combustiblematerialstooverlap firebox front facing IMPORTANT Noncombustible materials such as brick tile etc may overlap front facing but should never cover any necessary openings like louvered slots WARNING Do not allow noncombustible materials to cover any necessary openings li...

Страница 13: ... modify fireplace spacers INSTALLING GAS LINE NOTICE Aqualifiedserviceper son must connect heater to gas supply Follow all local codes IMPORTANT See Connecting to Gas Supply in your log set owner s manual for details on gas hookup You may run gas line from either side or back of firebox see Figure 9 Decide which side you want to run gas line from Note This is one option for installing shutoff valv...

Страница 14: ...to front hole on right side of firebox and fasten using remaining Phillips screw Hood Remove Replace Side Screws Loosen Top Screws Figure 12 Hood Placement Model May Vary From Illustration Hood INSTALLING FIREPLACE HOOD AND SCREEN 1 For Indoor models attach hood and front panel assembly by snapping panel assem bly into fireplace opening see Figure 12 OPTIONAL OUTSIDE AIR KIT MODEL AK4 AK4F Install...

Страница 15: ...RTS See Pages 17 19 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 Th...

Страница 16: ...039 Model PT32 32 Black Cat No F1040 Model PT32B 32 Brushed Brass Cat No F1041 Model PT32P 32 Platinum Cat No F1042 Model PT36 36 Black Cat No F1043 Model PT36B 36 Brushed Brass Cat No F1044 Model PT36P 36 Platinum Cat No F1045 Model PT42 42 Black Cat No F1046 Model PT42B 42 Brushed Brass Cat No F1047 Model PT42P 42 Platinum VENT FREE GAS LOGS Please visit Astria us com for specific models sizing ...

Страница 17: ...87 VALIANT36ZP3 F0388 QTY 1 J3957 Left Refractory Stacked White 1 J5946 Left Refractory Herringbone White 1 2 J3967 Rear Refractory Stacked White 1 J5942 Rear Refractory Herringbone White 1 3 J3962 Right Refractory Stacked White 1 J5944 Right Refractory Herringbone White 1 4 J6743 Bottom Refractory White 1 KEY NO Cat No DESCRIPTION VALIANT42ZP2 F0389 VALIANT42ZP3 F0390 QTY 1 J4065 Left Refractory ...

Страница 18: ...2 3 5 4 6 7 22 8 9 10 11 12 19 21 19 18 16 15 13 14 Cat No Model Interior F0385 Valiant32ZP2 White Stack F0386 Valiant32ZP3 White Herringbone F0387 Valiant36ZP2 White Stack F0388 Valiant36ZP3 White Herringbone F0389 Valiant42ZP2 White Stack F0390 Valiant42ZP3 White Herringbone ...

Страница 19: ...J5185 Refractory Retainer 2 9 J5186 Rear Refractory Retainer 1 10 RP108413 01 Firebox Top Shield 1 11 Firebox Top 1 12 Starter Pipe Collar 1 13 Insulation Pan 1 14 Fireplace Top Insulation 1 15 Fireplace Top 1 16 J6918 Top Spacer 4 17 Fireplace Surround 1 18 J4223 Gas Conduit Left and Right Assembly 2 19 J6934 Gas Knock Out Cover 3 5 20 J4011 Gas Conduit 2 20a J6951 Gas Conduit 2 J6952 Gas Conduit...

Страница 20: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Страница 21: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Страница 22: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Страница 23: ...fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use The Product is designed to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive tempe...

Страница 24: ...cal distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 126691 01 Rev B 06 2017 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Astria us com Record the following important information about your appliance Appliance model number Appliance serial number Date appliance was Installed Type of gas appliance uses Dealer name P126691 01 ...

Отзывы: