background image

Astria.US.com

127051-01D

11

VENTING INSTALLATION 

Continued

CHASE INSTALLATIONS

Instructions for chase installations are included with chase style ter-

mination chosen. In a multiple chase installation, be sure to provide 

adequate distance between terminations to prevent smoke spillage 

from one termination to another. We suggest that terminations be 

separated at least 24", center to center and stacked at a vertical height 

difference of 18" (see Figure 16).

Note:

 If a decorative shroud is to be installed, contact manufacturer 

for specifications.

24" Min.

24" Min.

18" 

Min.

Typ.

Figure 16 - Multiple Chase Installation

10'

2' Min.

10'

3' Min.

2' Min.

3' Min.

Level of 

Flue Gas 

Outlet

Figure 17 - 10 Foot Rule

10 FOOT RULE

All flue gas outlet chimney terminations must extend a minimum of 

3 feet in height above highest point where it passes through roof and 

must be at least 2 feet above highest point of the roof that is within 

a horizontal distance of 10 feet (see Figure 17).

FINISHING FIREPLACE

Combustible materials, such as wallboard, sheet rock, drywall, ply

-

wood, etc., may make direct contact with sides and top around fire-

place face. It is important that combustible materials do not overlap 

face itself. Brick, glass, tile or other noncombustible materials may 

overlap front face provided they do not obstruct essential openings 

such as louvered slots. When overlapping with a noncombustible 

facing material, use only noncombustible mortar or adhesive.

Storm Collar Installation (SC1)

Place storm collar over pipe and slide down until it is snug against 

open edge of flashing (see Figure 14). Use SC1 for all round termina

-

tions. Apply waterproof caulk around perimeter of collar to provide 

a proper seal.

Figure 14 - Storm Collar

Chimney 

Pipe

Waterproof 

Caulk

Storm 

Collar

Flashing

Terminations/Spark Arrestor

Fireplace system must be terminated with listed round top or chase 

terminations. In any case, refer to installation instructions supplied 

with termination. Terminations approved for this fireplace are RT-

8DM and RLT-8DM that can be used for flashing or chase and ET-

8DM, ETO-8DM, ETL-8DM and ETLO-8DM for chase style termination 

only. Figure 18 shows an RLT-8DM round top termination.

 CAUTION: Do not seal openings on the rooftop 

flashing. Follow the installation instructions provided 

with the termination being used.

Terminations with 16" slip pipe sections are available. RTT-8DM, and 

RLTT-8DM are approved for flashing installations. When needed, 

these adjustable terminations may be used in combination with pipe 

assembly to achieve correct chimney height.

Note:

 In the rare instance there is a problem with side driven rain or 

wind or chimney is not drafting properly, an ADS-8DM (Anti-Draft 

Shield) can be used with round terminations.

Attach Bracket 

Tabs to 

Outer Pipe 

(3 Places) 

Secure with 

Screws

RLT-8DM

Level of Flue 

Gas Outlet

Caulk

Collar

Flashing

Underlap Shingles 

Bottom Only

Figure 15 - Termination

Overlap 

Shingles Top 

and Sides

Flue Pipe 

of RLT-8DM 

Inside Inner 

Pipe of 

Chimney

Содержание Tuscan42P2

Страница 1: ...og heater see Accessories page 19 FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L autorité compétente comme le service municipal du bâtiment les pompiers etc doit être contacté avant l installation afin de déterminer la nécessité d obtenir un ...

Страница 2: ...dification of the fireplace components doors air inlet system and damper control b Use of any component part not manufactured or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Consult the local building codes as to the particular requirements concerned with the installation of all...

Страница 3: ...to treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide Poisoning Early signs of carbon monoxidepoisoningresemblethefluwithheadaches dizziness or nausea If you have these signs get fresh air at once Have the appliance inspected by a qualified service te...

Страница 4: ...USTIBLE WALL BOARD TOP SPACERS 0 TO 1 AIRSPACE TO COMBUSTIBLE MATERIAL NO COMBUSTIBLE MATERIAL ON FACE NO COMBUSTIBLE MATERIAL BELOW TOP SPACERS GAS LINE KNOCK OUT AIR KIT KNOCK OUTS GAS LINE STARTER SECTION 8DM PIPE INNER DIA OUTER DIA 15 KNOCK OUTS ELECTRICAL OUTLET LEFT SIDE RIGHT SIDE PERPENDICULAR NOT LESS THAN 12 TO SIDEWALL 41 48 42 8 39 12 48 36 24 8 1 8 10 5 8 12 5 8 10 5 8 6 3 4 14 1 4 2...

Страница 5: ...mum Maximum Chimney Height for Outdoor Installation The minimum height of the chimney measured from the base of the fireplace to the flue gas outlet of the termination is 8 feet minimum of 4 feet of chimney pipe sections required for outdoor installation Figure 1 Framing Dimensions Figure 2 Corner Installation FRAMING 1 Frame opening for fireplace using dimensions shown in Figures 1 and 2 Note Whe...

Страница 6: ...pan with provision for drainage be installed under the fireplace within the fireplace enclosure see Accessories page 19 HEARTH EXTENSION A hearth extension projecting a minimum of 20 in front of and a minimum of 12 beyond each side of fireplace opening is required to protect combustible floor construction in front of fireplace Fab ricate a hearth extension using a material which meets the followin...

Страница 7: ... 18 24 36 and 48 snap lock double wall pipe segments planned for maximum adaptability to individual site requirements Actual lengths gained after fitting overlaps must be taken into consideration lineal gain and are given in lineal gain chart see Figure 6 Lineal gain is actual measurable length of a part after two or more parts are connected Figure 6 Lineal Gain Hemmed End 8 Stainless Inner Pipe 1...

Страница 8: ... page 9 The height of a vertical chimney pipe supported ONLY by the fireplace must not exceed 20 feet Chimney heights above 20 feet must be supported USING ELBOW OFFSET 30E 12DMO 8DMR To clear overhead obstructions you may offset your chimney system using 30E 12DMO 8DMR 30 Offset return elbow A section or sections of chimney may be used between offsets and return elbow Transition pipe must be used...

Страница 9: ... 24 1 2 50 3 4 1 1 2 27 1 2 56 1 1 1 1 30 1 4 61 1 1 2 31 62 1 2 1 1 1 32 1 2 65 1 1 2 1 35 1 2 70 1 4 1 1 1 2 36 1 4 71 1 2 1 1 1 1 37 72 3 4 1 1 1 38 1 2 75 1 2 1 1 3 39 1 4 76 3 4 1 1 1 1 41 1 2 80 1 2 1 1 2 1 42 1 4 81 3 4 1 1 1 1 44 1 2 85 3 4 1 1 1 1 1 45 1 4 87 1 1 1 1 47 1 2 91 1 1 2 1 48 1 4 92 1 4 1 1 2 49 3 4 94 3 4 1 1 2 1 1 52 98 3 4 1 1 1 4 53 1 2 101 1 4 1 1 1 2 54 1 4 102 3 4 1 1 1...

Страница 10: ...lete separation from one floor space to an other or attic space as required by most codes When double wall pipe passes through a framed opening into an attic space firestop must be placed into an attic floor as shown in Figure 11 Figure 10 Firestop Spacer with Living Space Above Ceiling Figure 11 Firestop Spacer with Attic Space Above Ceiling IMPORTANT NOTICE When penetrating a ceiling into an att...

Страница 11: ...aterial use only noncombustible mortar or adhesive Storm Collar Installation SC1 Place storm collar over pipe and slide down until it is snug against open edge of flashing see Figure 14 Use SC1 for all round termina tions Apply waterproof caulk around perimeter of collar to provide a proper seal Figure 14 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Terminations Spark Arrestor ...

Страница 12: ...nduit sleeve if using a raised platform add height Provide sufficient gas line into fireplace chamber for fitting OPTIONAL GAS LINE INSTALLATION Figure 18 Typical Residential Installations VENTING INSTALLATION Continued connection see Figure 20 page 13 Note Secure incoming gas line to wood framing to provide rigidity for threaded end 4 Repack insulation around gas line and into sleeve opening Seal...

Страница 13: ...WARNING FIREPLACESEQUIPPEDWITHDOORS SHOULD BE OPERATED ONLY WITH DOORS FULLY OPENORDOORSFULLYCLOSED IFDOORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT OF THE FIREPLACE OPENING CREATING RISKS OF BOTH FIRE AND SMOKE WARNING Discontinue use of the appliance imme diately if doors are damaged and contact a qualified installer for repair Only doors certified with the appliance shall be used WARNING Do n...

Страница 14: ... guidelines instructions and warranty informa tion please refer to your homeowner s guide or contact your dealer Access Panel OPEN CLOSE Damper Handle Outside Air Kit Handle Keyway Slot Handle Retainer REPLACEMENT PARTS See Pages 15 to 17 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer P...

Страница 15: ...White Brick 1 J4144 Right Refractory Textured White Herringbone 1 11 J4073 Rear Refractory Textured White Brick 1 J4147 Rear Refractory Textured White Herringbone 1 12 J4506 Bottom Rear Refractory White Brick 1 13 J4508 Bottom Front Refractory White Brick 1 PARTS WOOD BURNING FIREPLACE MODELS TUSCAN42P2 AND TUSCAN42P3 Rear Left Side Front Bottom Bottom Right Side MODEL NO CATALOG NO Tuscan42P2 F05...

Страница 16: ...US com 127051 01D 16 PARTS WOOD BURNING FIREPLACE MODELS 9 24 16 31 25 16 4 30 32 19 12 23 20 28 17 8 1 5 21 2 18 11 14 3 13 22 10 6 35 29 7 33 34 26 27 15 MODEL NO CATALOG NO Tuscan42P2 F0542 Tuscan42P3 F0543 ...

Страница 17: ...Liner 1 11 See Page 15 Rear Refractory Brick Liner 1 12 See Page 15 Bottom Rear Refractory Brick Liner 1 13 See Page 15 Bottom Front Refractory Brick Liner 1 14 J3972 Firebox Support Leg 4 15 Damper Can Collar 1 16 J8013 Kit Screen Assembly 1 17 Firebox Top Assembly 1 18 J3980 Air Kit Door Assembly 1 19 Face Weldment 1 20 J4471 Air Deflector 1 21 Fireplace Top Insulation 1 22 Access Panel 1 23 J45...

Страница 18: ...F0882 18 8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock 30 OFFSET AND RETURN F0900 30E 8DM 30 Degree Offset and Return F0886 30E 8HT 30 Degree Hi Temp Offset and Return F1908 30E 12DMO 8DMR 30 Elbow Set 12 to 8 Craftsman...

Страница 19: ...on F0923 ETLO 8DM Square Top with Mesh and Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SLIP SECTION F0923 ETLO 8DM Square Top with Mesh and Slip Section STAINLESS STEEL HOOD Required when installing a vent free gas log in this fireplace F1053 HS42 42 Stainless Steel Hood w 4 Brow DRAIN PAN F1090 DP42 Drain Pan FIRESTOP THIMBLE F0911 ...

Страница 20: ...HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Support For Use With Chimney Heights In Excess of 30 F0888 RT 8HT Hi Temp Round Top with Mesh Screen F0889 RTT 8HT Hi Temp Round Top with Mesh Screen and Slip Sec tion F0890 RLT 8HT Hi Temp Round Top with Louvere...

Страница 21: ..._ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________...

Страница 22: ..._ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________...

Страница 23: ...or propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with th...

Страница 24: ...uecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 127051 01 Rev D 10 2015 P127051 01 WARRANTY KEEP THIS WARRANTY 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Model Number Serial Number Date Installed Dealer s Name Dealer s Phone Number Keep receipt for warranty verification ...

Отзывы: