Installation
900079-00, 02/2014
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
16
INSTALLATION SEQUENCE
The typical sequence of installation is outlined below; however, each installation is unique and may result in
variations to the steps described.
See the pages referenced in the following steps for detailed instructions.
Framing
1. Construct the Fireplace Framing
(
Page 16
).
2. Prepare the Fireplace Top Spacers
(
Page 18
).
3. Route the Gas Supply Line into the Fireplace
(
Page 18
).
4. Rough in the Electrical Supply, if Needed
(
Page 19
).
5. Prepare the Fireplace Nailing Flanges
(
Page 19
).
6. Place the Fireplace in the Framing and Secure
(
Page 19
).
Venting
7. Select a Horizontal or Vertical Vent System
(
Page 20
).
8. Install the Vent Restrictor (if necessary)
(
Page 20
).
9. Install the Vent System
(
Page 23
).
Electrical Connection
10. Complete the Field Wiring
(
Page 34
).
Gas Connection
11. Connect the Gas Line
(
Page 36
).
12. Verify Proper Fireplace Operation
(
Page 37
).
Finishing
13. Construct the Fireplace Framing
(
Page 54
).
14. Construct the Fireplace Framing
(
Page 55
).
15. Install the Glass Media
(
Page 55
).
16. Install the Baffle
(
Page 38
).
17. Install the Glass Door
(
Page 56
).
18. Adjust the Air Shutter to Ensure Proper Flame Appearance
(
Page 38
).
19. Install the Finishing Materials
(
Page 40
).
20. Install the Wall Switch Receiver
(
Page 43
).
21. Initialize the Remote Control System
(
Page 43
).
22. Attach the Safety-in-Operation Warning Labels
(
Page 43
).
1.
Construct the Fireplace Framing
1.
Frame the fireplace as illustrated in
Table 10
. All framing details must allow for a minimum clearance to combustible
framing members as shown in
Table 8
. Steel studs are strongly recommended where exposed to heat.
2.
Mount the fireplace on a fully supported base extending the full width and depth of the unit. If installed on
combustible materials, such as carpeting, vinyl tile, or combustible material other than wood flooring, the
appliance shall be installed on a metal or wood panel extending the full width and depth of the fireplace.
NOTE:
Headers may be in direct contact with the fireplace top standoff spacers when they are bent up vertically,
maintaining the 4 3/8” clearance to the fireplace top, but must not be supported by them or notched to fit around
them. All construction above the fireplace must be self-supporting. DO NOT use the fireplace for structural support.