NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

ATTACHING SAFETY IN OPERATION WARN-

INGS

Your fireplace has been furnished with safety instruc-

tion labels that are to be affixed to the operation and 

control points of the fireplace.  A safety instruction label 

should be affixed to the receiver wall switch plate where 

the fireplace is turned on and off 

(See 

Figure A

)

 and 

the remote control handheld transmitter 

(

Figure B

)

.  

The warnings should already have been put in place 

when the fireplace initial set-up was completed.  If they 

are not affixed at these spots, locate the multi-lingual 

adhesive labels provided with these instructions and 

proceed as follows:

1.  Locate the wall receiver that controls the fireplace 

(verify the switch operates the fireplace by turn-

ing it on and off).  Clean the wall receiver plate 

thoroughly to remove any dust and oils. Affix the 

label to the surface of the plate of the wall receiver  

that controls the fireplace 

(

Figure A

)

.  Choose 

the language primarily spoken in the home. 

2.  Locate the remote control transmitter and clean 

it thoroughly to remove any dust and oils.  Affix 

the label to the surface of handheld transmitter 

(

Figure B

)

.  Choose the language primarily spoken 

in the home. 

3.  If you are unable to locate the labels, please 

call Innovative Hearth Products or your nearest 

Innovative Hearth Products dealer to receive ad-

ditional safety instruction labels free of charge.
Cat. No. H8024 Replacement Label Kit 

INNOVATIVE HEARTH PRODUCTS

Astria.us.com

Note: English is red text on clear label. French and 

Spanish are white text on black label.

APPOSITION DES MISES EN GARDE RELATIVES à 

LA SÉCURITÉ D’UTILISATION

Votre foyer a été livré avec des étiquettes de sécurité qui 

doivent être collées à côté des dispositifs de contrôle du 

foyer.  Une étiquette de sécurité devrait être collée sur 

la plaque du récepteur mural contrôlant l’allumage du 

foyer 

(voir 

Figure A

)

 et sur le boîtier de la télécommande 

(

Figure B

)

.  Les mises en garde auraient dû être collées 

au moment de l’installation initiale du foyer.  Si ce n’est 

pas le cas, prenez les étiquettes adhésives multilingues 

fournies avec ces instructions et procédez comme suit:

1.  Repérez le récepteur mural qui contrôle le foyer 

(vérifiez que l’interrupteur contrôle le fonction-

nement du foyer en le faisant basculer de Marche 

à Arrêt, et vice-versa).  Nettoyez soigneusement la 

plaque du récepteur mural pour éliminer la poussière 

et les traces de graisse ou d’huile. Collez l’étiquette 

sur la surface de la plaque du récepteur mural qui 

contrôle le foyer 

(

Figure A

)

.  Choisissez la langue 

qui est principalement parlée dans la résidence du 

propriétaire. 

2.  Repérez la télécommande et nettoyez-la soigneuse-

ment pour éliminer la poussière et les traces de 

graisse ou d’huile.  Collez l’étiquette sur le boîtier de 

la télécommande 

(

Figure B

)

.  Choisissez la langue 

qui est principalement parlée dans la résidence du 

propriétaire. 

3.   Si vous ne trouvez pas les étiquettes, veuillez appeler 

Innovative Hearth Products ou votre distribu teur 

Innovative Hearth Products local pour recevoir 

gratuitement des étiquettes supplémentaires.
Étiquettes de remplacement, n° cat. H8024 

INNOVATIVE HEARTH PRODUCTS

Astria.us.com

Remarque : Le texte anglais est rouge sur un support 

transparent. Le texte français et espagnol est blanc 

sur un support noir.

COLOCACIóN DE ADVERTENCIAS DE SEGURIDAD 

EN OPERACIóN

Su chimenea incluye etiquetas de instrucciones de 

seguridad que deben colocarse en los puntos de 

operación y control de la chimenea. Se debe colocar 

una etiqueta de instrucciones de seguridad en la 

placa del interruptor de pared del receptor desde 

el cual se enciende y se apaga la chimenea 

(ver la 

Figura A

)

 y en el transmisor de control remoto 

(

Figura 

B

)

. Las advertencias ya deben haberse colocado cuando 

se completó la instalación inicial de la chimenea. Si 

no están colocadas en estos lugares, encuentre las 

etiquetas adhesivas multilingües proporcionadas con 

estas instrucciones y prosiga de la siguiente manera:

1.  Identifique el receptor de pared que controla la 

chimenea (verifique que el interruptor opera la 

chimenea encendiéndola y apagándola). Limpie bien 

la placa del receptor de pared para quitar el polvo y 

aceite. Pegue la etiqueta en la superficie de la placa 

del receptor de pared que controla la chimenea 

(

Figura A

)

.

 

Seleccione el idioma que más se habla 

en la casa. 

2.  Identifique el transmisor de control remoto y límpielo 

bien para quitar el polvo y aceite. Pegue la etiqueta 

en la superficie del transmisor 

(

Figura B

)

. Seleccione 

el idioma que más se habla en la casa. 

3.  Si no puede encontrar las etiquetas, sírvase llamar 

a Innovative Hearth Products o al distribuidor de 

Innovative Hearth Products más cercano para recibir 

etiquetas de instrucciones de seguridad adicionales 

gratuitas. 
Juego de etiquetas de repuesto - Nº de cat. H8024 

INNOVATIVE HEARTH PRODUCTS

Astria.us.com

Nota: La etiqueta en inglés es transparente con texto 

rojo. Las etiquetas en francés y español son negras 

con texto blanco.

HOMEOWNER’S INSTRUCTIONS -

 

ATTACHING SAFETY IN OPERATION WARNINGS

Remote

Off

On

PRG

SAFETY LABEL DIAGRAMS

DIAGRAMAS DE ETIQUETAS DE 

SEGURIDAD

DIAGRAMMES DES ÉTIQUETTES 

DE SÉCURITÉ

Figure A

Figure B

Illustrations are for example only. Your 
accessories may be different.

Les illustrations sont par exemple 
uniquement. Vos accessoires peuvent être 
différents.

Las ilustraciones son sólo ejemplos. Tu 
accesorios pueden ser diferentes.

Figura A

Figura B

Содержание Rhapsody 42TEN

Страница 1: ...e gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installationetl entretiendoivent treassur spar un ins...

Страница 2: ...VITRE EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas...

Страница 3: ...toca Mantenga a los ni os alejados de la chimenea en funcionamiento Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidri...

Страница 4: ...n 12 Vent Termination Clearances 13 Minimum Clearances to Combustibles 15 Wall Finishes Surrounds Mantels 16 Installation Preparation 16 Installation Installation Sequence 17 Construct the Fireplace F...

Страница 5: ...ultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s u...

Страница 6: ...or its operating controls is dangerous Improper installation or use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning CARBON MONOXIDE POISONING...

Страница 7: ...use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous Provide adequate clearances around air openings and adequate accessibility clearance for s...

Страница 8: ...el combinations will degrade the performance of this system may be dangerous and may void the warranty Electronic fireplaces are designed with an electronic intermittent pilot ignition system External...

Страница 9: ...n must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition or the Natural Gas and Propane Installation Code CSA B149 1 The firepl...

Страница 10: ...Manifold OUT Air shutter adjustment lever Lower right corner of fireplace NOTE Before accessing the test ports the fireplace must be OFF and COLD Turn OFF the main gas supply before connecting to the...

Страница 11: ...epair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts The flexible gas line connector used shall not exceed 36 914 mm in length The individual manual shutoff must...

Страница 12: ...on In selecting the location the aesthetic and functional use of the fireplace are primary concerns However vent system routing to the exterior and access to the fuel supply are also important The fir...

Страница 13: ...Termination Heights for Vents above Flat or Sloped Roofs NFPA 54 ANSI Z223 1 Gas Vent Rule Roof Pitch Termination Height Flat to 6 12 1 0 ft 0 3 m 6 12 to 7 12 1 25 ft 0 38 m 7 12 to 8 12 1 5 ft 0 46...

Страница 14: ...127 mm minimum 5 127 mm minimum G Clearance to inside corner 2 51 mm minimum 2 51 mm minimum H Clearance to each inside of center line extended above meter regulator assembly 36 910 mm within a height...

Страница 15: ...nclined vent component See Page 18 for clearance requirements to the nailing flange located at each side of the unit and any screw heads adjacent to it Hearth Extension A hearth extension is not requi...

Страница 16: ...mm 18 457 20 508 22 559 24 610 26 660 28 711 Fireplace Mantel depth Installation Preparation The fireplace is shipped with all gas controls and components installed and pre wired Before installing the...

Страница 17: ...nstall the Backlighting Reflector Page 39 17 Install the Firebox Liners Page 57 18 Optional Install the Backlighting Light Assemblies Page 39 19 Install the Glass Media Page 57 20 Install the Baffle P...

Страница 18: ...me opening depth with 1 2 13mm thick wall finish material For other wall finish thickness adjust frame opening depth and nailing flanges accordingly see Unit Nailing Flanges section C Min frame openin...

Страница 19: ...or plastic pipe NOTE See Page 54 for more information on Accessing the Control Compartment Figure 10 Front access panel Figure 11 Routing the gas line into the fireplace Access Panel Remove front acc...

Страница 20: ...as a chase There is no requirement for inspection openings in the enclosing wall at any of the joints in the vent pipe 6 Install the Vent Restrictor if necessary 1 Use the vent run descriptions in Fi...

Страница 21: ...gh an exterior wall no vent restrictor is required If installing more than 6 ft of vertical venting install the restrictor Figure 13 from inside or outside the unit in the inner fireplace collar The v...

Страница 22: ...1 2 38 191 mm The telescopic vent section is fitted with a locking inclined channel end identical to a normal vent section component and a plain end with three 3 pilot holes Slip the plain end over th...

Страница 23: ...2 0 3 480 40 1 1 0 0 10 12 79 5 6 625 0 1 0 2 0 3 492 41 1 0 1 0 10 12 81 6 75 0 0 0 1 1 2 499 5 41 625 0 0 0 1 10 11 91 5 7 625 0 0 2 0 1 3 504 42 1 0 0 1 10 12 93 7 75 0 0 0 0 2 2 511 5 42 625 0 0...

Страница 24: ...the roof The minimum vent height above the roof and or adjacent walls is specified in ANSI Z223 1 In Canada the current CAN CGA B149 1 installation code by major building codes Always consult your loc...

Страница 25: ...ing the firestop spacer must be installed on the top side of the joist Route the vent sections through the framed opening and secure the firestop spacer with 8d nails or other appropriate fasteners at...

Страница 26: ...ent section and position such that the vent column rises vertically use carpenters level Nail along perimeter to secure flashing or adjust roofing to overlap the flashing edges at top and sides only a...

Страница 27: ...Tables NOTE If the parameters of your vent run fall outside the parameters described herein consider installing the Power Vent Kit NOTE Rise per foot run ratios are acceptable all the way to level For...

Страница 28: ...ting u Vertical firestop spacer must be used anywhere vent pipe passes through a combustible floor or ceiling Horizontal firestop spacer must be used anywhere vent pipe passes through a combustible wa...

Страница 29: ...may NOT be attached directly to the appliance collar A minimum 12 pipe section must be used between the fireplace collar and a 90 elbow 1 Analyze the vent route and determine the number of vent sectio...

Страница 30: ...the additional venting components needed in addition to the termination and adaptor for a range of wall thicknesses 11 Attach the termination adaptor Attach the adaptor SV4 5RCH provided with the term...

Страница 31: ...e silicone Figure 26 Venting Connection and Exterior Wall Recessing of the Horizontal Termination To help minimize water infiltration it is recommended that the Firestop Spacer SV4 5HF be installed on...

Страница 32: ...rmination kit Horizontal Vent Figures Tables NOTE Secure Vent rigid vent pipe and terminal are shown in the figures Secure Flex flexible vent pipe and terminal may also be used NOTE If the parameters...

Страница 33: ...t restrictor if required A 90 elbow may NOT be attached directly to the appliance collar A minimum 12 pipe section must be used between the fireplace collar and a 90 elbow Table 24 Top Vent Three 90 E...

Страница 34: ...e flexible pipe and slide the flexible vent over the inner and outer adaptor collars NOTE Outer vent pipe is pulled away to show inner vent pipe details 1 3 4 44 mm flexible vent and adaptor outer col...

Страница 35: ...ent circumference than Secure Vent collars Secure Flex vent has a longer center tube to improve ease of installation 8 Complete the Field Wiring CAUTION The ground supply lead must be connected to the...

Страница 36: ...ction box can be moved to the bottom of the fireplace for bottom electrical entry 3 Remove the cover plate knockout then feed the power supply wire through the knockout opening and into the unit junct...

Страница 37: ...ntil after Installing the Firebox Liners on Page 57 11 Connect the Gas Line The gas control valve is located in the lower control compartment Figure 32 All codes require a shutoff valve mounted in the...

Страница 38: ...ing a soapy water solution is an effective leak test solution but it is not recommended because the soap residue that is left on the pipes fittings can result in corrosion over time 1 Light the firepl...

Страница 39: ...hting Light Assemblies See the kit literature for more information 18 Install the Glass Media 1 See Page 57 for instructions on Installing the Glass Media 19 Install the Baffle 1 With the baffle orien...

Страница 40: ...opened The length and configuration of the chimney vent will afffect flame appearance A fireplace operated with the air shutter opened too far may have flames that appear blue and transparent These we...

Страница 41: ...Hearth Products Rhapsody Linear Direct Vent Gas Fireplaces 41 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Figure 37 Flame Appearance Table 26 Main Burner Shutter Opening Factory Setting Models Natur...

Страница 42: ...per combustion 2 Secure heat shield to top front of unit with two screws NOTE Install a second field supplied noncombustible board over the supplied noncombustible board The fireboard supplied with th...

Страница 43: ...lace Insulation and combustible material NOT ALLOWED in clearance zones around vent components Header Cleanface Finish Surround Bezel Finish Position of Top and Bottom Nailing Flanges depends on type...

Страница 44: ...re 43 Correctly align polarity 2 Insert the 4 provided AA batteries into the receiver battery bay behind the wall switch plate Correctly align polarity 3 Position the wall switch receiver three positi...

Страница 45: ...TO SCALE 24 Attach the Safety in Operation Warning Labels 1 Attach the furnished safety instruction labels at all fireplace operation and control points Page 46 NOTE The installer MUST ensure these wa...

Страница 46: ...t pour liminer la poussi re et les traces degraisseoud huile Collezl tiquettesurlebo tier de la t l commande Figure B Choisissez la langue qui est principalement parl e dans la r sidence du propri tai...

Страница 47: ...d Small SquareTermination 20 with Shield and Firestop see 750247M and 750204M H6183 SV4 5HF5 Firestop Spacer 5 rigid H2152 SV4 5CGV 1 Vertical Termination Cap High Wind H6184 SF4 5HF5 Firestop Spacer...

Страница 48: ...uare Termination for flex without flex 56L74 SFVT30 VerticalTerminationforflex flatto6 12 withflexadaptor sectionofrigidvent roof supportcollarassembly roofflashingand stormcollar see750052M 77L87 SFK...

Страница 49: ...r r duire au minimum le risque d incendie d explosion ou la production de monoxyde de carbone pouvant causer des dommages mat riels des blessures ou la mort Le tecnicien agr est responsable de l insta...

Страница 50: ...the burner assembly with the attached venturi tube Figure 44 8 Remove the control compartment access door and gasket Figure 44 Figure 44 Removing the Burner and Accessing the Control Compartment Cont...

Страница 51: ...test the new pressure regulator assembly and all gas line joints for leaks Page 51 20 Attach the conversion information label to the rating plate 21 Locate the external test ports just under the door...

Страница 52: ...anemia those under the influence of alcohol and those at high altitudes NOTE Do not place furniture or other combustible materials within 36 of the front of viewing area s NOTE Children and adults sho...

Страница 53: ...ment parl e dans la r sidence du propri taire 2 Rep rezlat l commandeetnettoyez lasoigneuse ment pour liminer la poussi re et les traces de graisseoud huile Collezl tiquettesurlebo tierde la t l comma...

Страница 54: ...Valves As part of your fireplace installation the installer may have provided a readily accessible gas shutoff valve near your fireplace Make sure this valve is fully open before operating the firepla...

Страница 55: ...ated manually ON OFF 1 To test the batteries in the wall switch receiver press the handheld remote control ON OFF key Figure 43 one time If the wall switch receiver emits a beep the batteries have eno...

Страница 56: ...stat 1 Repeatedly press the THERMOSTAT key to cycle the thermostat between ON OFF and SMART modes Figure 48 2 To change the temperature scale F to C With the system in the OFF position press the THERM...

Страница 57: ...mode NOTE Continuous mode is indicated by a pilot that comes ON and remains lit when the fireplace is OFF Installing the Firebox Liners Install the side panels from kit 1 Align screw hole in top flan...

Страница 58: ...ng the glass door frame The glass door of this appliance must only be replaced as a complete unit as provided by the manufacturer Do not attempt to replace broken cracked or chipped glass separately D...

Страница 59: ...oor alignment and sealing are important to the operation and performance of the fireplace Ensure the door seal is contacting the frame and that no air leaks are present 3 Align the screw holes below t...

Страница 60: ...ssembly and proper sealing of the venting system components However more frequent periodic inspections and cleanings should be performed by the homeowner NOTE Prior to the first use of the fireplace a...

Страница 61: ...l before handling Use a clean dry empty shop vac to remove glass media Wash the media in warm soapy water Rinse and dry before reinstalling Reinstalling the glass media Carefully follow the placement...

Страница 62: ...flame rod and hood Ensure the pilot flame engulfs the flame sensor Checking Vent System Qualified Service Technician Remove baffle inspect the vent system at the top and at the base within the firebo...

Страница 63: ...e Black Porcelain H8421 IPK MBLKP RAP54 Nake Black Porcelain H8422 NPK BLP RAP54 Nake Black Satin Paint H8423 NPK BLS RAP54 Floor Kits Designer style floors require one glass media kit 5 lb bag Reflec...

Страница 64: ...ts Table 37 Backlighting Kits SimFlame Catalog No Model No Description H8866 IPBLK RAP42 Panel Backlighting Kit 42 models H8429 IPBLK RAP54 Panel Backlighting Kit 54 models Power Vent Kits Table 38 Po...

Страница 65: ...onal injury or loss of life A This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand B BEFORE OPERATING smell all around the appl...

Страница 66: ...tez l appareil sous tension 9 Placez l interrupteur du r cepteur en position REMOTE 10 Appuyez sur le bouton ON OFF pour s lectionner ON 11 Si applicable Ajustez le thermostat sur la t l commande l aj...

Страница 67: ...e technician if necessary d Air in the gas line Purge gas line of air call a service technician if required e Unit is not receiving power Replace unit battery backup 3 The main Burner comes on but the...

Страница 68: ...l Module H8656 1 H8856 1 15 Glass Door Latch H8433 1 H8433 1 16 Flex Gas Connector Assembly 93L32 1 93L32 1 17 Orifice Connector H7847 1 H7847 1 18 ON OFF Jumper Switch H8809 1 H8809 1 19 Assembly Har...

Страница 69: ...mFlame 26 27 28 29 30 Table 43 Homeowner Replacement Parts Description 42 54 Catalog Number Qty Catalog Number Qty 25 Remote Control Transmitter Kit H8753 1 H8753 1 26 Glass Door H8799 1 H8431 1 27 To...

Страница 70: ...Operation 900077 02 07 2015 Innovative Hearth Products Rhapsody Linear Direct Vent Gas Fireplaces 70 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE NOTES...

Страница 71: ...e flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal us...

Страница 72: ...er Date fireplace was Installed Type of gas fireplace uses Dealer name P900077 02 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifica...

Отзывы: