FIREPLACE INSTALLATION

FRAMING

1.  Frame opening for fireplace using dimen

-

sions shown in Figures 2 and 3.

2.  If  fireplace  is  to  be  installed  directly  on 

carpeting, tile (other than ceramic) or any 

combustible  material  other  than  wood 

flooring, fireplace must be installed upon 

a metal or wood panel extending full width 

and depth of fireplace.

3.  Set fireplace directly in front of this open

-

ing and slide unit back until nailing flanges 

touch side framing.

4.  Check level of the fireplace and shim with 

sheet metal if necessary.

5.  Before  securing  fireplace  to  prepared 

framing, ember protector (provided) must 

be placed between hearth extension (not 

supplied) and under bottom front edge of 

fireplace to protect against glowing embers 

falling through. If fireplace is to be installed 

on a raised platform, a Z-type ember pro

-

tector (not supplied) must be fabricated to 

fit  your  required  platform  height.  Ember 

protector should extend under fireplace a 

minimum of 1 

1

/

2

". Ember protector should 

be  made  of  galvanized  sheet  metal  (28 

gauge minimum to prevent corrosion.

6.  Using screws or nails, secure fireplace to 

framing through flanges located on sides 

of fireplace.

SELECTING LOCATION

To  determine  the  safest  and  most  efficient 

location for the fireplace, you must take into 

consideration the following guidelines:
1.  The location must allow for proper clear

-

ances (see Figures 5 and 6).

2.  Consider a location where fireplace will 

not be affected by drafts, air conditioning 

ducts, windows or doors.

3.  A location that avoids cutting of joists or 

roof rafters will make installation easier.

4.  An  outside  air  kit  is  available  with  this 

fireplace (see 

Optional Outside Air Kit

 on 

page 7).

MINIMUM CLEARANCE TO 

COMBUSTIBLES

Back and sides of fireplace 

1

/

2

" min.*

Front of fireplace 

48" min.

Floor** 

0" min.

Perpendicular wall to opening 

18" min.

Top spacers 

0" min.

Mantel clearances 

see 

Mantels

, page 6

Chimney outer pipe surface 

2" min.

* Not required at nailing flanges
** See step 2 of 

Framing

  WARNING:  Do  not  pack 

required air spaces with insula

-

tion or other materials. 

A firestop 

thimble  (38FST  or  FST30)  is 

recommended.

Minimum/Maximum Chimney Height for 

Residential Installation

Minimum height of chimney, measured from 

base of fireplace to flue gas outlet of termina

-

tion, is 16 feet for straight flue or a flue with 

one elbow set. Maximum distance between 

elbows is 6 feet. For systems with two elbow 

sets,  minimum  height  is  22  feet.  Maximum 

height of any system is 50 feet. This measure

-

ment includes fireplace, chimney sections and 

height of termination assembly at level of the 

flue gas outlet (see Figure 14, page 10).

Minimum/Maximum Chimney Height for 

Outdoor Installation

Minimum height of chimney, measured from 

base of fireplace to flue gas outlet of termina

-

tion, is 9.5 feet (minimum of 4 feet of chimney 

pipe sections required for outdoor installation).

Figure 3 - Framing Dimensions

Figure 4 - Corner Installation

71" (50" Models)

100" (50" Models)

65" (42" Models)

92" (42" Models)

86.5" (36" Models)

61" (36" Models)

Maintain 1 

1

/

2

"

Clearance 

at Sides and 

Back of Fireplace

1

/

2

" Clearance

Not Required at 

Nailing Flanges 

30.125"

59" (50" Models)

58.125"

67.125"

51.25" (42" Models)

45.25" (36" Models)

28.250" (36" Models)

Содержание Oracle Cat 42

Страница 1: ...ated manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate WARNING If the information in these...

Страница 2: ...in your appliance it also contains information that will enable you to obtain re placement parts or accessory items when needed Keep it with your other important papers This fireplace is approved for...

Страница 3: ...tedfortheapplication in fireplace and refer to fire log warnings and caution markings on packaging prior to use Thisfireplaceisnotintendedtobe used as a substitute for a furnace to heat an entire home...

Страница 4: ...ICATIONS 42 MODEL 22 3 4 30 1 2 29 4 3 8 15 3 4 5 8 17 5 8 67 61 49 7 1 30 11 58 42 51 1 8 4 1 2 3 1 2 9 1 2 10 1 2 81 2 13 17 OUTSIDE AIR ACCESS GAS LINE ACCESS 42 HEARTH 1 1 4 23 Ref 41 3 8 26 3 8 2...

Страница 5: ...ONS Continued 50 MODEL 38 1 2 28 1 2 43 8 17 5 8 19 1 4 24 49 30 11 61 67 58 7 1 59 50 4 1 2 3 1 2 9 1 2 10 1 2 8 1 2 13 17 GAS LINE ACCESS OUTSIDE AIR ACCESS 50 HEARTH 1 1 4 23 Ref 49 3 8 34 3 8 21 3...

Страница 6: ...ducts windows or doors 3 A location that avoids cutting of joists or roof rafters will make installation easier 4 An outside air kit is available with this fireplace see Optional Outside Air Kit on pa...

Страница 7: ...rth extension from shifting and seal gap between fireplace frame and hearth extension with a noncombustible material see Figure 5 WARNING Hearthextension is to be installed only as shown in Figure 4 F...

Страница 8: ...ure 7 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of 1 4 x 20 in size Air Inlet Location Must Allow For Bushes or Snow Vent Hood Required for Wall Installation Air Inlet Eye...

Страница 9: ...l not come apart if properly locked It is not necessary to add screws to keep the chimney together excep tion see Figure 9 USING ELBOW OFFSETS 30E 12DM 1 To achieve desired offset you may install comb...

Страница 10: ...gure 13 Firestop Spacer with Attic Space Above Ceiling Existing Ceiling Frame Firestop Spacer Screws or Staples Min of 8 Firestop Spacer Screws or Staples Min of 8 PENETRATING ROOF To maintain a 2 cle...

Страница 11: ...ecure in position by nailing through shingles see Figure 15 DO NOT NAIL THROUGH FLASHING CONE Storm Collar Installation SC2 1 Place storm collar over pipe and slide down until it is snug against the o...

Страница 12: ...re 19 10 Foot Rule Terminations Spark Arrestor The fireplace system must be terminated with the listed round top or chase terminations In any case refer to the installation instructions supplied with...

Страница 13: ...Brackets 2 Install the left and right firebrick walls There is a bracket with 2 tabs on the bottom of each firebrick wall Angle the wall into the fireplace opening and into the slots on the side of t...

Страница 14: ...g Place a wet towel over the bucket making sure it is directly on the surface of grout mixture This will keep the mixture moist and it will not dry out before use 5 Grout all joints where two firebric...

Страница 15: ...RTH PRODUCTS grate only see Parts page 22 This grate has been designed to keep the operation of your fireplace safe and efficient FIREBRICK WALL INSTALLATION Continued Figure 25 Installing Grate Retai...

Страница 16: ...apply soap and water solution to all connectionsandjoints Bubbles forming show a leak Correct all leaks at once DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPER ATEANYAPPLIANCE IFALEAK IS DE...

Страница 17: ...ontinued PUREFIRE HOOD INSTALLATION 1 The PureFire hood supplied with this fire place is packaged in a separate box and placed in the firebox during shipping 2 Remove hood from box Locate brackets qua...

Страница 18: ...n on door adjustment Figure 31 Installing Bi Fold Doors Spring Clip Insert Pin into Spring Clip Pivot Hole Insert Bottom Pivot Pin into Hole Fold Door and Slide Top Pins Into Track Figure 32 Adjusting...

Страница 19: ...ls as pitch wax laden logs very dry mill end lumber and large amounts of paper or cardboard boxes can create an excessively hot fire and should not be burned in this fireplace Always keep the fire wel...

Страница 20: ...oleum products leaves paper products cardboard or salt driftwood Refer to your INNOVATIVE HEARTH PROD UCTS Homeowner s Guide included with your fireplace for proper fire building technique and ash rem...

Страница 21: ...l for U S EPA s Voluntary Fireplace Program For proper operation catalyst must be replaced every 3 to 5 years 125574 03 For more information go to www epa gov burnwise U S Environmental Protection Age...

Страница 22: ...CEMENT PARTS If this product is missing a part or has a broken component please do not return it to the store Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 to answer questions and replace parts un...

Страница 23: ...www Astria US com 126761 01A 23 PARTS MODELS ORACLE CAT 42 AND ORACLE CAT 50 1 21 20 5 6 7 10 9 11 12 13 16 17 15 14 8 24 23 3 25 18 2 22 19 4 26 27 28 29 30...

Страница 24: ...20 Inner Dome Assembly 1 21 Smoke Shield 1 22 Damper Control Bracket 1 23 109457 02 Screen 42 2 109457 01 Screen 50 2 117556 02 Screen 42 Stainless 2 117556 01 Screen 50 Stainless 2 24 110146 03 Scre...

Страница 25: ...www Astria US com 126761 01A 25 PARTS MODELS ORACLE CAT 42 AND ORACLE CAT 50 Picture may vary from actual 1 6 4 8 7 3 2 5 7 7 7 8 9...

Страница 26: ...2 Red 1 125451 01 Right Herringbone 50 Red 1 125415 02 Right Stacked 42 Ivory 1 125439 02 Right Stacked 50 Ivory 1 125427 02 Right Herringbone 42 Ivory 1 125451 02 Right Herringbone 50 Ivory 1 6 12541...

Страница 27: ...0E 50 Ebony BDMO50G 50 Pewter BDMO50C 50 Oiled Bronze DOUBLE WALL PIPE 12 12DM 18 12DM 24 12DM 36 12DM 48 12DM 12 12HT 18 12HT 24 12HT 36 12HT and 48 12HT 30 OFFSET AND RETURN 30E 12DM and 30E 12HT OP...

Страница 28: ...ROOF FLASHING V6F 10DM 0 to 6 12 Pitch V12F 10DM 6 12 to 12 12 Pitch ACCESSORIES Continued SQUARE CHASE TOP TERMINATION STL 12D AND STL 12DMP BLACK ROUND TOP TERMINATIONS RLT 12D AND RLT 12HT STORM CO...

Страница 29: ...www Astria US com 126761 01A 29 NOTES...

Страница 30: ...aic42M3 Ivory Herr Full Stack Mosaic42M5 Ivory Herr Split Stack Mosaic50M2 Red Full Stacked Mosaic50M4 Red Split Stacked Mosaic50M2 Ivory Stacked Mosaic50M4 Ivory Split Stacked Mosaic50M3 Red Herr Ful...

Страница 31: ...puccino Estate42P3 Herringbone Creamer Estate42P3 Herringbone Gray Estate50P2 Stacked Rust Estate50P2 Stacked Cappuccino Estate50P2 Stacked Creamer Estate50P2 Stacked Gray Estate50P3 Herringbone Rust...

Страница 32: ...ship via parcel delivery services IMPORTANT NOTICE A manufactured shroud which has been approved by a national testing agency for use with this fireplace may be used if installed in accordance with t...

Страница 33: ...www Astria US com 126761 01A 33 NOTES...

Страница 34: ...gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may...

Страница 35: ...RANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ______________________...

Страница 36: ...126761 01 Rev A 01 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126761 01...

Отзывы: