background image

www.Astria.US.com

126682-01A

3

Due  to  high  temperatures,  the 

appliance should be located out 

of traffic and away from furniture 

and draperies.

Do not place clothing or other 

flammable material on or near 

the appliance. Never place any 

objects  in  the  firebox  or  on 

logs.

Firebox  front  and  screen  be-

comes  very  hot  when  running 

firebox. Keep children and adults 

away from hot surfaces to avoid 

burns or clothing ignition. Fire-

box  will  remain  hot  for  a  time 

after shutdown. Allow surfaces 

to cool before touching.

Carefully supervise young chil-

dren when they are in the room 

with firebox.

Keep the fireplace area clear and 

free from combustible materials, 

gasoline, and other flammable 

vapors and liquids.

You must operate this fireplace 

with  the  provided  fireplace 

screen and hood in place. Make 

sure  these  parts  are  in  place 

and screens are closed before 

running installed gas log heater. 

Replace hood with INNOVATIVE 

HEARTH  PRODUCTS  model 

109511-01  50",  109511-02  42", 

or 109511-03 36" only. This hood 

has been designed to keep the 

operation of your fireplace safe 

and efficient.

SAFETY

Continued

1.  Do not use this firebox as a wood burning 

fireplace. Use only decorative unvented 

room heaters (log sets).

2.  Do not add extra logs or ornaments such as 

pine cones, vermiculite or rock wool. Using 

these added items can cause sooting.

3.  Use only the provided hood. See 

Parts

page 18.The firebox canopy (hood) must 

not be modified or replaced with a canopy 

(hood)  that  may  be  provided  with  the 

unvented decorative room heater.

4.  Vent-free gas log heaters installed in these  

fireboxes require fresh air ventilation to 

run properly. See 

Air for Combustion and 

Ventilation

, page 8.

5.  Do not run vent-free heaters installed in 

these fireboxes
• where flammable liquids or vapors are 

used or stored

• under dusty conditions

6.  Do not use this firebox to cook food or 

burn paper or other objects.

7.  Turn unit off and let cool before servicing. 

Only  a  qualified  service  person  should 

service and repair firebox.

8.  Operating vent-free heaters installed in 

these fireboxes above elevations of 4,500 

feet could cause pilot outage.

9.  Do  not  use  the  firebox  if  it  has  been 

under water.

10. Before using furniture polish, wax, carpet 

cleaner or similar products, turn heater 

off. If heated, the vapors from these prod-

ucts may create a white powder residue 

within  burner  box  or  on  adjacent  walls 

and furniture.

11. Provide adequate clearances around air 

openings.

f i r e - p a r t s . c o m

Содержание Marquee36

Страница 1: ...xplosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO...

Страница 2: ...anufacturer This firebox has been tested under Z21 91b 2007 for use with approved ANSI Z21 11 2 decorativetype unventedroom heater IMPORTANT Read this owner s manualcarefullyandcompletely before tryin...

Страница 3: ...urning fireplace Use only decorative unvented room heaters log sets 2 Do not add extra logs or ornaments such as pine cones vermiculite or rock wool Using these added items can cause sooting 3 Use onl...

Страница 4: ...EBOX PLANNING Plan where you will install the firebox This will save time and money later when you install the firebox Before installation consider the following 1 Where firebox will be located Allow...

Страница 5: ...PECIFICATIONS 36 MODEL Figure 1 36 Model Marquee36 Picture may vary from actual fireplace 30 1 2 29 30 11 1 8 54 1 2 7 7 8 7 36 45 1 8 35 16 97 16 50 365 16 7 3 8 111 8 3 3 4 4 7 8 36 HEARTH 1 1 4 20...

Страница 6: ...ATIONS Continued 42 MODEL Figure 2 42 Model Marquee42 Picture may vary from actual fireplace 4 7 8 54 1 2 7 7 8 7 36 5 16 50 42 51 1 8 32 3 8 3 3 4 30 5 16 8 3 4 13 3 5 16 9 7 16 30 11 1 8 42 HEARTH 1...

Страница 7: ...CATIONS Continued 50 MODEL Figure 3 50 Model Marquee50 Picture may vary from actual fireplace 365 16 50 8 3 4 13 35 16 97 16 59 1 8 50 7 7 8 7 30 54 1 2 11 1 8 32 3 8 3 3 4 38 5 16 4 7 8 50 HEARTH 1 1...

Страница 8: ...ermine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms WA...

Страница 9: ...he actual Btu Hr used is more than the maximum Btu Hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoining room I...

Страница 10: ...heaters installed in this firebox create warmaircurrents Thesecurrents move heat to wall surfaces next to firebox Installing firebox next tovinylorclothwallcoveringsor operating firebox where impuri t...

Страница 11: ...e built in fire box you must meet the minimum allowable clearance between mantel shelf and top of firebox opening shown in Figure 7 These are the minimum allowable mantel clearances for a safe install...

Страница 12: ...2 Install gas piping to firebox location See Gas Line Installation on page 16 and Con necting to Gas Supply in log set owner s manual 3 Carefully set firebox in front of rough opening with back of fi...

Страница 13: ...nst a wall in your home The firebox and cabinet mantel can be installed directly on the floor Mantels may be avail able from your retailer or custom built for your home 1 Assemble cabinet mantel as in...

Страница 14: ...el Grate retaining bracket should be positioned as shown in Figure A WARNING LIFTING HAZARD SINGLE PERSON LIFT COULD CAUSE INJURY USE ASSISTANCE WHEN MOVING OR LIFTING Figure B Installing Refractory P...

Страница 15: ...rear at gas line conduit sleeve if usingaraisedplatform addheight Provide sufficient gas line into fireplace chamber for fitting connection see Figure 16 Note Secure incoming gas line to wood framing...

Страница 16: ...tive gas appliance must comply with the Standard for Decorative Gas Appliance for Installation in Solid Fuel Burning Fireplaces ANS Z21 60 or Z21 84 and shall also be installed in accordance with the...

Страница 17: ...s a broken component please do not return it to the store Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 to answer questions and replace parts under warranty Note Use only original replacement part...

Страница 18: ...www Astria US com 126682 01A 18 PARTS 36 42 AND 50 MODELS 11 10 11 13 14 15 16 14 3 22 20 21 20 1 19 5 14 15 16 13 12 11 9 7 6 8 17 2 12 18 4 fire parts com...

Страница 19: ...109457 02 Screen 42 2 109457 01 Screen 50 2 117556 03 Screen 36 Stainless 2 117556 02 Screen 42 Stainless 2 117556 01 Screen 50 Stainless 2 21 20806 Screen Rod 36 2 110146 03 Screen Rod 42 2 110146 0...

Страница 20: ...c50M2 Ivory Stacked F0352 Mosaic50M4 Ivory Split Stacked F0353 Mosaic50M3 Red Herringbone Full Stack F0354 Mosaic50M5 Red Herringbone Split Stack F0355 Mosaic50M3 Ivory Herringbone Full Stack F0356 Mo...

Страница 21: ...r acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use The Pro...

Страница 22: ...TY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased _________________________...

Страница 23: ...NOTES fire parts com...

Страница 24: ...126682 01 Rev A 02 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126682 01 fire parts com...

Отзывы: