background image

NOTES

26

Printed in U.S.A. © 2013  Innovative Hearth Products LLC

P/N 900200-00, Rev. NC  12/2013

Innovative Hearth Products

1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

Innovative Hearth Products

Astria™ Brand EPA Wood Burning Fireplace

Limited Lifetime Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria™ Brand EPA Wood Burning Fireplace ("Product") to be free from defects in materials 

and workmanship at the time of manufacture. The Product body, firebox and ceramic glass carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime 

Warranty against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 

Limited Lifetime Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If 

repair or replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will 

also pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS 

AND LIMITATIONS to this Limited Lifetime Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of installation. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the 

date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This Limited Lifetime Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.
This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The Product body and firebox carry the Limited Lifetime Warranty from the date of installation. Vent components, trim components and paint are excluded from 

this Limited Lifetime Warranty. The following do not carry a Limited Lifetime Warranty but are warranted as follows:

Cast Iron Heat Exchanger 

– Replacement for five years from the date of installation

Cast iron parts

 – Replacement for one year from the date of installation

Catalyst

 – Carries a separate warranty. Refer to the warranty certificate provided for that part

Electrical components

– Repair or replacement for one year from date of installation

Gaskets

 – Replacement for one year from the date of installation.

Gold & nickel plating 

– Replacement for two years from date of installation. Excludes tarnishing

Refractory & screens

 – Replacement for two years from date of installation. Excludes hairline cracks

Removable air tubes

 – Repair or replacement for seven years from date of installation. IHP prevailing labor rates for years one through five.

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component, unless otherwise noted

Parts not otherwise listed carry a 90 day warranty from the date of installation.
Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance. (The Product must be subject to normal use with approved fuels listed in the Operation 

Manual provided with the product. Fuel products with abnormal burning characteristics, including but not limited to fuel such as driftwood, coal or plywood and wood products 

using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly; IHP stoves, inserts and high efficiency EPA 

fireplaces are approved for burning dry seasoned wood only.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions 

provided with the Product; (d) damages, repairs or  inefficiency resulting from faulty installation or application of the Product.
Coverage of this Limited Lifetime Warranty is conditional upon the appliance being operated without the use of grates, irons or any other method to elevate the fire.
IHP is not responsible for inadequate system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction conditions which 

may generate negative air pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for smoking conditions caused by inadequate 

chimney height, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions. Certain IHP Products are listed for use with Security 

Chimneys International, Ltd. chimney systems only. Use of chimney components other than that specified in the Product manual will void the Product warranty.
This Limited Lifetime Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction which are 

not manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due 

to any malfunction or defect in equipment are not covered by this Limited Lifetime Warranty. All replacement or repair components will be shipped F.O.B. from the nearest 

stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.
In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after 

replacement or repair, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular 

use or purpose, and there is no implied condition of fitness for a particular use or purpose.
IHP makes no expressed warranties except as stated in this Limited Lifetime Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.
No one is authorized to change this Limited Lifetime Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this Limited 

Lifetime Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this Limited Lifetime Warranty and to decide, in its sole discretion, upon the method of settlement.
To receive the benefits and advantages described in this Limited Lifetime Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP. 
Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. 

IHP shall in no event be responsible for any warranty work done by a con-

tractor that is not approved without first obtaining IHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/ 

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.ASTRIA.US.COM.

Содержание Ladera-BK

Страница 1: ...127 Report 14 181 EPA Cert No 706 WARNING The fireplace cannot be operated without a door or firescreen Consult your dealer to select the correct replacement door or firescreen The fireplace is equipp...

Страница 2: ...n in front ofanopenflamewhenthewindow is opened Keep any combustible furniture materials or decorative pillows at least 48 1219 mm from the front fireplace opening WARNING Never leave your fireplace u...

Страница 3: ...ASHT S 2100 HT6000 HT6103 or AC manufactured by Security Chimneys Inter national only OR 7 diameter chimney Model ASHT and HT6103manufacturedbySecurityChimneys International only 6 and 7 Chimneys Incl...

Страница 4: ...ra fireplace will operate best if at tention is given to operating the unit with the damper fully opened after refueling in order to bring the firebox and the chimney system up to their optimum operat...

Страница 5: ...n your area Carbon Monoxide Monitor Recommended Carbon Monoxide Poisoning Early signs of carbonmonoxidepoisoningaresimilartotheflu withheadaches dizzinessand ornausea Ifyou have these signs obtain fre...

Страница 6: ...gure 2B Top Baffle Removal Figure 2A Top Baffle Removal Top Baffle Removal Prior to Cleaning The Chimney Before starting to clean your chimney we recommend that you remove the top baffle to avoid creo...

Страница 7: ...slight amount of friction The door gasket does not need to be tight in all areas since a small amount of leakage is not hazardous or detrimental to the performance of your fireplace Figure 5 Door Inst...

Страница 8: ...ndtogetdirtyunlessthefuel firebox and glass are maintained at hot temperatures see Refueling For Best Performance To clean the glass there are a number of specially designedcleaners YourIHPdealercanre...

Страница 9: ...place and the other half must extend on the floor over which the hearth extension will be built see Figure 7A The safety metal strip must cover the entire width of the fireplace The combustible floor...

Страница 10: ...nce From Back Spacer to Wall 26 5 8 676 mm 32 3 4 830 mm 35 7 8 910 mm 20 1 2 521 mm 22 1 2 570 mm 25 1 8 637 mm 6 1 8 154 mm 22 1 4 565 mm 31 3 4 805 mm 37 5 8 956 mm 10 254 mm 11 278 mm 13 1 4 337mm...

Страница 11: ...s the rest of the building below the attic SEE NOTE Facing 1 Combustible material must be installed flushwiththefireplace Itmaynotproject in front of and on the fireplace i e the steel facade of the f...

Страница 12: ...et Grill Outlet Grill WARNING The outlet grills should not be installed fac ing upward through a floor Danger of burns can result if grills in floor are stepped on 38 965mm Min 330mm x 330mm 10 3 1m M...

Страница 13: ...m to ceiling uCombustibles are not allowed below top spacers above the fireplace Facing in front of fireplace must be non combustible below this area u NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 13...

Страница 14: ...ausing negative pressure in the house resulting in smoke entering the house from the fireplace This situation is aggravated in modern airtight houses To overcome this problem we strongly recommend tha...

Страница 15: ...especially prone to flow reversal 2 The IHP fireplace model Ladera may be installed only with Security Chimneys International 6 diameter chimney systems The Ladera fireplace may also be installed with...

Страница 16: ...the roof and the flashing with roofing pitch see Figures 26 and 27 For sloping roofs place the flashing under the upper shingles and on top of the lower shingles Nail the flashing to the roof using ro...

Страница 17: ...up the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below install a firestop Se...

Страница 18: ...48 AC 6 15 A 4 13 16 122 mm 6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78...

Страница 19: ...locations climates where temperatures will fall below 32 F 0 C we recommend that you use the insulated wall radiation shield since it will maintain the home s thermal barrier RSM and RSMI30 RSMI45 Can...

Страница 20: ...ided with the support CHIMNEY MODEL MAXIMUM HEIGHT OF SUPPORTED CHIMNEY Offset Support Roof Support ASHT HT6103 6 dia 28 feet 8 54 m 29 feet 8 84 m S 2100 HT6000 6 dia 18 feet 5 49 m 20 feet 6 1 m AC...

Страница 21: ...tion Temporarily install the ASHT elbow on the top of the fireplace and using a level mark with an oval the location where the flue liner will enter the masonry chimney 2 In the middle of the oval dri...

Страница 22: ...tured by Security Chimneys International only 6 diameter chimney AC air cooled Secure Temp ASHT or Nova Temp HT6103 and Secure Temp S 2100 or Nova Temp HT6000 6 diameter chimney for relining masonry c...

Страница 23: ...ack refractory PR SR2826 Left side refractory PR SR2828 Right side refractory PR SR2827 Front refractory 2 pieces PR SR2829 Secondary air tube back PR SR2906 Secondary air tube middle or front PR SR28...

Страница 24: ...ng 6FR 6FR 1 12 7 12 5 30 6FAR 6FAR 8 12 12 12 30 45 6FBR 6FBR Storm Collar 6FC 6FC Chimney Adaptors Chimney Adaptor 6 S2100 HT6000 6UCA Chimney Adaptor 6 to 7 ASHT HT6103 6AW7 AC Air Cooled Chimney S...

Страница 25: ...liner CANADA ONLY BISUMA Masonry Chimney Adaptor 30 BISUMA30 for use with Tubinox liner BISUMA30 Gravity Kit Accessories Elbow 90 8 dia 7B26ZE90 7B26ZE90 Elbow 45 8 dia 7B26ZE45 7B26ZE45 Telescopic le...

Страница 26: ...NOTES 26...

Страница 27: ...inder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry s...

Страница 28: ...nt parts See Page 23 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be ship...