background image

EPA  Wood-Burning Fireplace

P/N  900113-00  REV. B  03/2015

Ladera-BK

MODELS

Ladera™

INSTALLATION AND 

OPERATION INSTRUCTIONS

SAVE THESE INSTRUCTIONS

FOR FUTURE REFERENCE

This installation manual will enable you to obtain a safe, efficient 

and dependable installation of your fireplace system. Please read 

and understand these instructions before beginning your installation.

Do not alter or modify the fireplace or its components under any cir-

cumstances.  Any modification or alteration of the fireplace system, 

including but not limited to the fireplace, chimney components and 

accessories, may void the warranty, listings and approvals of this system 

and could result in an unsafe and potentially dangerous installation.

IHP wood-burning fireplaces are designed for use as a supplemental 

heater.   They are not intended for continuous use as a primary heat 

source.

Listed to standards:
ULC-S610 and UL-127
Report #  14-181
EPA Cert. No. 706

       WARNING

  The fireplace cannot be operated without a door 

or firescreen.  Consult your dealer to select the 

correct replacement door or firescreen.

•  The fireplace is equipped with a blower, electri

-

cal connection must be made prior to fireplace 

installation

•  Important! To assure proper alignment of glass 

doors:  Install  this  fireplace  in  a  square  and 

plumb condition, using shims as necessary at 

sides and/or bottom.

•  Install the fireplace only as described in these 

instructions.

     

WARNING

 

Hot!  Do  not  touch!    The  glass  and 

surfaces of this appliance will be hot 

during operation and will retain heat 

for a while after shutting off the appli-

ance.  Severe burns may result. 

• 

 

Carefully supervise children in the 

same room as appliance.

 

If small children are present in the home, it is 

recommended that this appliance be fitted with 

an adjustable safety gate or barrier screen.

A French manual is available upon request. Order P/N 900114-00.

Ce manuel d’installation est disponible en francais, simplement en faire 
la demande. Numéro de la pièce 900114-00.

P900113-00

C

US

Содержание Ladera-BK

Страница 1: ...127 Report 14 181 EPA Cert No 706 WARNING The fireplace cannot be operated without a door or firescreen Consult your dealer to select the correct replacement door or firescreen The fireplace is equipp...

Страница 2: ...n in front ofanopenflamewhenthewindow is opened Keep any combustible furniture materials or decorative pillows at least 48 1219 mm from the front fireplace opening WARNING Never leave your fireplace u...

Страница 3: ...ASHT S 2100 HT6000 HT6103 or AC manufactured by Security Chimneys Inter national only OR 7 diameter chimney Model ASHT and HT6103manufacturedbySecurityChimneys International only 6 and 7 Chimneys Incl...

Страница 4: ...ra fireplace will operate best if at tention is given to operating the unit with the damper fully opened after refueling in order to bring the firebox and the chimney system up to their optimum operat...

Страница 5: ...n your area Carbon Monoxide Monitor Recommended Carbon Monoxide Poisoning Early signs of carbonmonoxidepoisoningaresimilartotheflu withheadaches dizzinessand ornausea Ifyou have these signs obtain fre...

Страница 6: ...gure 2B Top Baffle Removal Figure 2A Top Baffle Removal Top Baffle Removal Prior to Cleaning The Chimney Before starting to clean your chimney we recommend that you remove the top baffle to avoid creo...

Страница 7: ...slight amount of friction The door gasket does not need to be tight in all areas since a small amount of leakage is not hazardous or detrimental to the performance of your fireplace Figure 5 Door Inst...

Страница 8: ...ndtogetdirtyunlessthefuel firebox and glass are maintained at hot temperatures see Refueling For Best Performance To clean the glass there are a number of specially designedcleaners YourIHPdealercanre...

Страница 9: ...place and the other half must extend on the floor over which the hearth extension will be built see Figure 7A The safety metal strip must cover the entire width of the fireplace The combustible floor...

Страница 10: ...nce From Back Spacer to Wall 26 5 8 676 mm 32 3 4 830 mm 35 7 8 910 mm 20 1 2 521 mm 22 1 2 570 mm 25 1 8 637 mm 6 1 8 154 mm 22 1 4 565 mm 31 3 4 805 mm 37 5 8 956 mm 10 254 mm 11 278 mm 13 1 4 337mm...

Страница 11: ...s the rest of the building below the attic SEE NOTE Facing 1 Combustible material must be installed flushwiththefireplace Itmaynotproject in front of and on the fireplace i e the steel facade of the f...

Страница 12: ...et Grill Outlet Grill WARNING The outlet grills should not be installed fac ing upward through a floor Danger of burns can result if grills in floor are stepped on 38 965mm Min 330mm x 330mm 10 3 1m M...

Страница 13: ...m to ceiling uCombustibles are not allowed below top spacers above the fireplace Facing in front of fireplace must be non combustible below this area u NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 13...

Страница 14: ...ausing negative pressure in the house resulting in smoke entering the house from the fireplace This situation is aggravated in modern airtight houses To overcome this problem we strongly recommend tha...

Страница 15: ...especially prone to flow reversal 2 The IHP fireplace model Ladera may be installed only with Security Chimneys International 6 diameter chimney systems The Ladera fireplace may also be installed with...

Страница 16: ...the roof and the flashing with roofing pitch see Figures 26 and 27 For sloping roofs place the flashing under the upper shingles and on top of the lower shingles Nail the flashing to the roof using ro...

Страница 17: ...up the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below install a firestop Se...

Страница 18: ...48 AC 6 15 A 4 13 16 122 mm 6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78...

Страница 19: ...locations climates where temperatures will fall below 32 F 0 C we recommend that you use the insulated wall radiation shield since it will maintain the home s thermal barrier RSM and RSMI30 RSMI45 Can...

Страница 20: ...ided with the support CHIMNEY MODEL MAXIMUM HEIGHT OF SUPPORTED CHIMNEY Offset Support Roof Support ASHT HT6103 6 dia 28 feet 8 54 m 29 feet 8 84 m S 2100 HT6000 6 dia 18 feet 5 49 m 20 feet 6 1 m AC...

Страница 21: ...tion Temporarily install the ASHT elbow on the top of the fireplace and using a level mark with an oval the location where the flue liner will enter the masonry chimney 2 In the middle of the oval dri...

Страница 22: ...tured by Security Chimneys International only 6 diameter chimney AC air cooled Secure Temp ASHT or Nova Temp HT6103 and Secure Temp S 2100 or Nova Temp HT6000 6 diameter chimney for relining masonry c...

Страница 23: ...ack refractory PR SR2826 Left side refractory PR SR2828 Right side refractory PR SR2827 Front refractory 2 pieces PR SR2829 Secondary air tube back PR SR2906 Secondary air tube middle or front PR SR28...

Страница 24: ...ng 6FR 6FR 1 12 7 12 5 30 6FAR 6FAR 8 12 12 12 30 45 6FBR 6FBR Storm Collar 6FC 6FC Chimney Adaptors Chimney Adaptor 6 S2100 HT6000 6UCA Chimney Adaptor 6 to 7 ASHT HT6103 6AW7 AC Air Cooled Chimney S...

Страница 25: ...liner CANADA ONLY BISUMA Masonry Chimney Adaptor 30 BISUMA30 for use with Tubinox liner BISUMA30 Gravity Kit Accessories Elbow 90 8 dia 7B26ZE90 7B26ZE90 Elbow 45 8 dia 7B26ZE45 7B26ZE45 Telescopic le...

Страница 26: ...NOTES 26...

Страница 27: ...inder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry s...

Страница 28: ...nt parts See Page 23 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be ship...

Отзывы: