Installation and Operation Instructions

Astria® Indoor Fireplace with Catalyst

Models 

Georgian Cat 42               Georgian Cat 50

PFS

®

US

C

P/N 126640-01   Rev. D   10/2015

REPORT NO. F09-095 

P126640-01

SAVE THIS BOOK

This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also 

contains information that will enable you to obtain replacement parts or accessory items when needed. Keep 

it with your other important papers.

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.

This wood burning fireplace complies with UL127 

CAN/ULC-S610-M87 standard as a FACTORY 

BUILT FIREPLACE.

Ce foyer au bois est conforme aux UL 127 CAN/ULC-

S610-M87 norme comme une USINE CONSTRUITE 

CHEMINÉE.

This fireplace is approved for use as a wood burning fireplace or for use with a vented gas log approved to

ANSI Z21.60 or Z21.84 standards or for use with a vent-free gas log heater approved to ANSI Z21.11.2 standard

FOR CANADA: The authority having jurisdiction 

(such as the municipal building department, fire 

department, etc.) should be contacted before 

installation to determine the need to obtain a permit.

POUR LE CANADA: L’autorité compétente (comme le 

service municipal du bâtiment, les pompiers, etc.) doit 

être contacté avant l’installation afin de déterminer la 

nécessité d’obtenir un permis.

These models meet the EPA Wood Burning Fireplace Program Phase 2 emission level. NOTE: To ensure proper 

fireplace operation, the catalyst should be replaced at a minimum of 3 years and a maximum of 5 years.

This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace 

system. Please read and understand these instructions before beginning your installation.

Do not alter or modify the fireplace or its components under any circumstances. Any modification or alteration of 

the fireplace system, including but not limited to the fireplace, chimney components and accessories, may void the 

warranty, listings and approvals of this system and could result in an unsafe and potentially dangerous installation.

IMPORTANT! TO ASSURE PROPER ALIGNMENT OF GLASS DOORS: INSTALL THIS FIREPLACE IN A SQUARE 

AND PLUMB CONDITION, USING SHIMS AS NECESSARY AT SIDES AND/OR BOTTOM.

Содержание Georgian Cat 42

Страница 1: ...d FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CA...

Страница 2: ...s in the vicinity of this or any other appliance Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Do not place clothing or other flammable...

Страница 3: ...s and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNINGIMPROPERFUEL I E CHAR COAL CAN RESULT IN CARBON MONOXIDE POISON ING WHICH MAY LEAD TO DEATH Carbon Monoxide Poisoning Ea...

Страница 4: ...Continued 42 MODEL 22 3 4 30 1 2 29 4 3 8 15 3 4 5 8 17 5 8 67 61 49 7 1 30 11 58 42 51 1 8 4 1 2 3 1 2 9 1 2 10 1 2 81 2 13 17 OUTSIDE AIR ACCESS GAS LINE ACCESS 42 HEARTH 1 1 4 23 Ref 41 3 8 26 3 8...

Страница 5: ...IONS Continued 50 MODEL Figure 2 50 Model Georgian Cat 50 38 1 2 28 1 2 43 8 17 5 8 19 1 4 24 49 30 11 61 67 58 7 1 59 50 4 1 2 3 1 2 9 1 2 10 1 2 8 1 2 13 17 GAS LINE ACCESS OUTSIDE AIR ACCESS 50 HEA...

Страница 6: ...s and height of termination assembly at level of the flue gas outlet see Figure 14 page 10 FRAMING 1 Frame opening for fireplace using dimensions shown in Figures 3 and 4 2 If fireplace is to be insta...

Страница 7: ...rial see Figure 5 WARNING Hearth extension is to be installed only as shown in Figure 5 Figure 5 Hearth Extension Seal Gap Fireplace Front Ember Protector Fireplace Front Raised Hearth Fireplace Front...

Страница 8: ...e Section 34 5 8 48 12DM 48 12HT Pipe Section 46 5 8 RLT 12D RLT 12HT Round Termina tion 7 3 4 STL 12D Square Chase Top with Slip Section 7 to 15 The lineal gain for the terminations is measured to th...

Страница 9: ...tions of 12 18 24 36 and 48 length of double wall pipe see offset chart and Figure 9 2 Chimney weight above offset rests on return elbow Straps must be securely nailed to rafters or joists see Figure...

Страница 10: ...restopspacersarerequiredateachpointwherethechimneypenetrates a floor space Their purpose is to establish and maintain the required clearancebetweenthechimneyandthecombustiblematerials Whenthe pipepass...

Страница 11: ...5 Min 30 Min 2 Min 2 Min 2 Min Opening A Figure 14 Roof Opening Measurements Nail Only Outer Perimeter of Flashing Storm Collar Flashing Cone Underlap Shingles at Bottom Overlap Shingles Top and Sides...

Страница 12: ...re to provide adequate distance between terminations to prevent smoke spillage from one termination to another We suggest that terminations be separated at least 24 center to center and stacked at a v...

Страница 13: ...ING OR LIFTING Figure 20 Installing Hearth and Leading Brick panels Hearth Panel Side leading brick Panel 3 Install the left and right firebrick walls There is a bracket with 2 tabs on the bottom of e...

Страница 14: ...e 5 Grout all joints where two firebrick walls come together 6 Using a trowel remove excess grout mixture by moving trowel in the direction of the joint Grout mixture in the joint should now be flush...

Страница 15: ...hook up should be done by your supplier or a qualified service person Note Before you proceed make sure your gas supply is turned off Use only a 1 2 black iron pipe and appropriate fittings 1 Remove...

Страница 16: ...requirements for Gas Fired Log Lighters for Wood Burning Fireplaces Draft NO 4 dated August 1993 If you install a decorative gas appliance vented gas log the deco rative gas appliance must comply wit...

Страница 17: ...igure 31 Installing Bottom Door Frame and Air Deflector Hex Screw Bottom Door Frame Ash Lip Ash Lip Air Deflector OPERATION AND MAINTENANCE GUIDELINES GLASS DOORS Glassdoorsareoptionalwiththefireplace...

Страница 18: ...re building technique and ash removal procedures These fueling guidelines must be fol lowed in order to achieve maximum emissions performance from the PureFire System OPERATION The proper use of a woo...

Страница 19: ...ally recognized certification body that this model qualifies at the Phase 2 emissions level for U S EPA s Voluntary Fireplace Program Better Worse FIREPLACE SMOKE EMISSIONS RANGE Higher Emissions Low...

Страница 20: ...Astria US com 126640 01D 20 PARTS MODELS 42 AND 50 1 21 20 5 6 7 10 9 11 12 13 16 17 15 14 8 24 23 3 25 18 2 22 19 4 26 27 28 29 30...

Страница 21: ...4369 Conduit Two 2 18 Heat Shield Support 1 19 J6020 Ash Box Assembly 1 20 Inner Dome Assembly 1 21 Smoke Shield 1 22 Damper Control Bracket 1 23 J4341 Screen 42 2 J4340 Screen 50 2 24 J4391 Screen Ro...

Страница 22: ...included for convenience CATALOG NO MODEL NO DESCRIPTION F0366 Estate42P2 Stacked Rust F1367 Estate42P2 Stacked Cappuccino F0368 Estate42P2 Stacked Creamer F0369 Estate42P2 Stacked Gray F0370 Estate42...

Страница 23: ...Wall Pipe Snap Lock F0933 18 12DM 18 Section Double Wall Pipe Snap Lock F0934 24 12DM 24 Section Double Wall Pipe Snap Lock F0935 36 12DM 36 Section Double Wall Pipe Snap Lock F0936 48 12DM 48 Section...

Страница 24: ...2D Round Top Termination with Louvered Screen F0960 RLT 12HT Hi Temp Round Top Termination with Louvered Screen FIRESTOP THIMBLE F0944 FST10 Firestop Thimble LABEL UL127 50PK WARNING HOT Fire Risk Ins...

Страница 25: ...ey Support F0960 RLT 12HT Round Top w Louvers F0961 AP 12HT Anchor Plate Collar Assembly Masonry Fireplaces F0951 CAK 12 Cold Air Collar Kit When ordered alone this part cannot ship via parcel deliver...

Страница 26: ...____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______...

Страница 27: ...sing a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burni...

Страница 28: ...lso to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2014 IHP LLC P N 126640 01 Rev D 10 2015 P126640 01 1508 Elm Hill Pike Suit...