Installation
900285-01 08/2016
Innovative Hearth Products
Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces
44
NOTE:
To install the hood after installing the non-combustible fi nish material over the black surface above the
fi replace opening, the bottom edge of the fi nish material must be 5/8” above the top edge of the hood to allow
clearance for installation and removal of the hood.
20.
Reinstall the Included Barrier
WARNING
Reinstall any barrier removed before operating the fi replace. The barrier is designed to
reduce the risk of burns from hot glass. Do not operate the fi replace without the barrier
installed.
NOTE:
All models must have a barrier installed prior to operation.
1.
Open the control compartment door
(
Page 53
)
.
2.
Hold the barrier in front of the glass door and slide it up into the slots above the glass door and under the hood.
3.
Slide the barrier bottom down into the slots below the glass door, securing it in place.
21.
Install the Finishing Materials
1.
Complete fi nished interior wall.
NOTE:
To install the fi replace facing fl ush with the fi nished wall, position framework to accommodate the thickness
of the fi nished wall.
NOTE:
In contemporary models only, fi nish wall fl ush to face of unit and install facade base and panel. Frame
assembly to complete the front of the fi replace (see facade installation instructions,
Page 45
)
.
Figure 40 - Combustible Wall Framing
Figure 41 - Face Mounting Elements
Top Face Brackets
Fireplace face foot slots
NOTE:
See
Cold Climate Insulation on
Page 10
and
Vent Termination Clearances on
Page 12
.
22.
Attach the Safety-in-Operation Warning Labels
1.
Attach the furnished safety instruction labels at all fi replace operation and control points
(
Page 47
)
.
NOTE:
The installer MUST ensure these warnings are properly attached during installation. The warning labels are a
critical means of informing consumers of safe operation practices.
23.
Installing Batteries for Backup and Wall Switch
1.
Locate the battery backup and place four (4)
AA
batteries in the backup battery holder
(
Page 38
)
.
2.
Locate the wall switch and secure four (4)
AA
batteries in the wall switch battery holder
(
Page 38
)
.
NOTE:
Replace batteries as a part of standard maintenance
(
Page 62
)
and as needed when troubleshooting
(
Page 73
)
.
Top Of
Appliance
3”
(77 mm)
This Area
Must Remain
Clear of
Combustible
Materials
1” Min.
(26 mm)
4” Clearance
Minimum
Hood
Standoff Provides
Space From
Combustible Materials
Stand Off Must Be Bent
To Vertical Position
Non-Combustible Front
Fireboard Standoff
Combustible Finished