NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Installation and Operation Instructions
900300-01, 01/2016
Innovative Hearth Products
Eros
TM
Direct-Vent Gas Fireplace
WARNING
Electronic models of these appli-
ances are equipped with a three-
prong (grounding) plug utilized
in connecting the electronic
components to the junction box
in the lower compartment. This
grounding plug provides protec-
tion against shock hazard and
should be plugged directly into
the properly grounded three-
prong receptacle. DO NOT cut
or remove the grounding prong
from the plug.
NOTE: Supply wires may be alternatively con-
nected to the outlet using the screw terminals,
however the black supply wire must be wired to
a terminal that is opposite (across the outlet) the
point where the white supply wire is connected.
Bipolar
Terminal
Screw
Ground Wire
Connection
White
(supply)
Black
(supply)
Figure 47
Step 6.
WIRING - OPTIONAL FORCED AIR
BLOWER KIT
FBK-100, FBK-200 and FBK-250 Kits
(See
Figure 49
on
Page 30
for wiring) -
An electrical receptacle is provided for the instal-
lation of the
FBK-100
,
FBK-200 and FBK-250
forced air blower kits. Electrical power must be
connected to this receptacle in order to operate
these blowers. Install the blower kits according
to the installation instructions provided with the
kits. See
Figure 13 on Page 13
showing where
blower should be located on unit.
Outlet Receptacle
Junction Box
Field-provided Metal Junction Box
Cover Plate With Screw
View Of Left
Bottom Corner Of Unit
Receptacle, Junction Box
and Cover Plate Installation
Fireplace
Side
Junction Box
knock-out (2
places each side)
Valve Access Side
Latching magnet
not shown
Press snap
bushing into the
knock-out for
control switch
wires.
Step 7. CONNECTING GAS LINE
Make gas line connections. All codes require a
shut-off valve mounted in the supply line.
Figure
50
illustrates two methods for connecting the
gas supply. The flex-line method is acceptable
in the U.S., however, Canadian requirements
vary depending on locality. Installation must
be in compliance with local codes. A sediment
trap is recommended in the gas piping within
the home to prevent moisture and debris in the
line from damaging the valve.
These appliances are equipped with a gas flex
line for use (where permitted) in connecting the
unit to the gas line. A gas flex line is provided
to aid in attaching the direct vent appliance to
the gas supply. The gas flex line can only be
used where local codes permit. Refer to
Figure
51
for flex line location. The flex line is rated for
both natural and propane gas. A manual shut off
valve is also provided with the flex line.
The gas control valve is located in the lower
control compartment.
The gas controls can be found behind the hinged
drop-down panel.
Open the control compartment access panel,
by lifting panel approximately 1/2" to disengage
and swing the panel open from top.
Remove the bottom compartment door by
sliding the hinge pin, located at the door’s left
side, to the right until it disengages from the
left corner post hole. Pull the door diagonally
to the left, away from the fireplace.
The lower control compartment door on the
side opposite the valve lifts on and off.
The millivolt control valve has a 3/8"
(10 mm) NPT thread inlet port. The electronic
control valve has a 1/2" (13 mm) NPT thread
inlet port and is fitted with a 1/2" x 3/8" (13 mm x
10 mm) NPT fitting.
Secure all joints tightly using appropriate
tools and sealing compounds (ensure propane
resistant compounds are used in propane
applications).
IMPORTANT NOTE:
The gas valve OFF/ON
switch is shown in
Figure 46
on
Page 28.
It
is integral with the gas valve and should be set
to the
ON
position.
Figure 48
CAUTION
Remove the carton support from
the control compartment before
operating the appliance.