Figure 7 - Lineal Gain

Figure 6 - Outside Air Kit

Secure to Collars with Metal Tape, Screws 

or Straps (Min. of 1/4" x 20" in size)

Air Inlet 

Location 

Must Allow 

For Bushes 

or Snow

Vent Hood 

Required for 

Wall Installation

Air Inlet 

Eyebrow

Vented Crawl Space

(Check Local Codes 

Before Installing in a 

Vented Crawl Space)

 WARNING: The opening in 

collar around chimney at top of 

fireplace must not be obstructed. 

Never use blown insulation to fill 

chimney enclosure.

Hemmed 

End

8" Stainless 

Inner Pipe

12 

3

/

8

Galvanized 

Outer Pipe

VENTING INSTALLATION

Continued

ASSEMBLY AND INSTALLATION OF 

DOUBLE WALL CHIMNEY SYSTEM

Each double wall chimney section consists of 

a galvanized outer pipe, a stainless steel in

-

ner flue pipe and a wire spacer. Pipe sections 

must be assembled independently as chimney 

is installed. When connecting chimney directly 

to fireplace, inner flue pipe section must be 

installed first with lanced side up. Outer pipe 

section can then be installed over flue pipe 

section  with  hemmed  end  up.  Press  down 

on  each  pipe  section  until  lances  securely 

engage  hem  on  fireplace  starter. The  wire 

will assure proper spacing between inner and 

outer pipe sections.

Note: For Canada, use chimney parts desig-

nated HT.

 Opening in collar around 

chimney at top of fireplace must 

not  be  obstructed.  Never  use 

blown insulation to fill chimney 

enclosure.

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

36"

Fireplace

37 

1

/

2

"

12-8DM

12-8HT

Pipe Section

10 

5

/

8

"

18-8DM

18-8HT

Pipe Section

16 

5

/

8

"

24-8DM

24-8HT

Pipe Section

23 

5

/

8

"

36-8DM

36-8HT

Pipe Section

34 

5

/

8

"

48-8DM

48-8HT

Pipe Section

46 

5

/

8

"

RT-8DM

Round Termination

7

/

8

"*

RTL-8DM

Round Termination

3

/

4

"*

RLT-8DM

Round Termination

1

/

2

"

RTT-8DM

Round Termination 

with Slip Section

7

/

8

" to

 

23 

1

/

8

"*

RTTL-8DM Round Termination 

with Slip Section

1

/

2

" to 

 

21 

1

/

2

"*

RLTT-8DM Round Termination 

with Slip Section

1

/

2

" to 

 

21 

1

/

4

"*

ET-8DM

Square Chase-Top

12"*

ETO-8DM

Square Chase-Top 

with Mesh

12"*

ETL-8DM

Square Chase-Top 

with Slip Section

7" to 15"*

ETLO-8DM

Square Chase-Top 

with Mesh & Slip 

Section

12" to 

 

25 

1

/

2

"*

* The lineal gain for the terminations is 

measured to the flue gas outlet height.

f i r e - p a r t s . c o m

Содержание CAT36P2

Страница 1: ...e not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is u...

Страница 2: ...C FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL PFS US C This fireplace is approved for use as a wood burning fire place or for use with a vented gas log approved to ANS Z21 60 and Z21 84 standa...

Страница 3: ...istributor IMPORTANT Check local codes before installing this fireplace Before beginning installation of this fireplace read these instructions through completely This INNOVATIVE HEARTH PRODUCTS firep...

Страница 4: ...COMBUSTIBLE MATERIAL ON FACE GAS LINE KNOCK OUTS AIR KIT KNOCK OUT GAS LINE KNOCK OUTS ELECTRICAL OUTLET LEFT SIDE RIGHT SIDE 9 125 11 435 14 437 41 250 37 41 35 21 8 32 5 14 25 22 3 5 8 717 1 11 217...

Страница 5: ...mum Chimney Height for Outdoor Installation The minimum height of the chimney mea sured from the base of the fireplace to the flue gas outlet of the termination is 7 1 2 feet minimum of 4 feet of chim...

Страница 6: ...conductiv ity of K 0 84 BTU IN FT HR F or less at 1 thick For example if material selected has a K factor of 0 25 such as glass fiber the following formula would apply 0 25 x 1 0 0 30 thickness requi...

Страница 7: ...2 from fireplace must not be placed less than 12 from top opening of fireplace NFPA STD 211 Sec 7 3 3 3 Figure 5 Mantel Clearances to Combustible Material The maximum height for the air vent can not e...

Страница 8: ...alled over flue pipe section with hemmed end up Press down on each pipe section until lances securely engage hem on fireplace starter The wire will assure proper spacing between inner and outer pipe s...

Страница 9: ...ed It is not necessary to add screws to keep chimney to gether exception see Figure 10 page 9 USING ELBOW OFFSETS 30E 8DM 1 To achieve desired offset you may install combinations of 12 18 24 36 and 48...

Страница 10: ...4 1 1 27 3 4 56 3 4 1 30 60 3 4 1 1 33 66 1 1 36 71 1 1 38 1 4 75 2 41 1 4 80 1 4 1 1 1 45 86 3 4 2 46 3 4 89 1 2 1 1 1 51 97 1 1 53 1 4 101 2 1 56 1 4 106 1 4 2 59 1 4 111 1 2 1 1 1 61 3 4 115 1 2 2...

Страница 11: ...erimeter of flashing to provide a proper seal FIRESTOP SPACERS 3600FS 8DM 1 Firestop spacers are required at each point where chimney penetrates a floor space Their purpose is to establish and maintai...

Страница 12: ...ded with the termination being used VENTING INSTALLATION Continued Attach Bracket Tabs to Outer Pipe 3 Places Secure with Screws RTL 8DM Level of Flue Gas Outlet Caulk Collar Flashing Underlap Shingle...

Страница 13: ...ls do not overlap face itself Brick glass tile or other noncombustible materials may overlap front face provided they do not obstruct essential openings such as louvered slots When overlapping with a...

Страница 14: ...of fireplace and pull out insu lation from gas line conduit sleeve Save insulation for reuse Note Secure incoming gas line to wood framing to provide rigidity for threaded end 4 Repack insulation aro...

Страница 15: ...ingadec orative vented gas log damper mustberemovedorpermanently locked in fully open position and glassdoorsmustbeinfullyopen position The following tips should be used to assure that both fireplace...

Страница 16: ...d water Do not use any abrasive material to clean glass Do not clean glass with any cool water if glass is still hot from fire and smoke A gas line or gas log lighter may be installed for the purpose...

Страница 17: ...INES The fireplace grate must always be secured to the retaining brackets provided The position of the grate must be centered against the back wall of the firebox Burn only dry seasoned cured wood wit...

Страница 18: ...d to function or there is thermal crumbling Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 for replacement parts WARRANTY INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 warranty obligations for the P...

Страница 19: ...ria US com 126767 01A 19 PARTS WOOD BURNING FIREPLACE MODELS CAT36P2 AND CAT36P3 9 26 16 27 16 27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 18 11 14 3 13 22 10 6 31 7 37 38 36 28 29 24 23 15 33 fire par...

Страница 20: ...Damper Can Collar 1 16 106691 01 Screen Rod 2 17 Firebox Top Assembly 1 18 Air Kit Door Assembly 1 19 Face Weldment 1 20 125562 02 Air Deflector 1 21 Fireplace Top Insulation 1 22 107775 01 Access Pan...

Страница 21: ...Right Refractory Smooth White Brick 1 108165 01 Right Refractory Smooth White Herringbone 1 11 106660 03 Rear Refractory Textured White Brick 1 108166 03 Rear Refractory Textured White Herringbone 1 1...

Страница 22: ...is missing a part or has a broken component please do not return it to the store Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 to answer questions and replace parts under warranty Note Use only or...

Страница 23: ...P36 ANTI DRAFT SHIELD Round Top Termination Only ADS 8DM STORM COLLAR SC1 1 ROUND TOP TERMINATIONS WITH LOUVERS RLT 8DM RLT 8HT ROUND TOP TERMINATIONS WITH LOUVERS WITH SLIP SECTION RLTT 8DM RLTT 8HT...

Страница 24: ...a parcel delivery services IMPORTANT NOTICE A manufactured shroud which has been approved by a national testing agency for use with this fireplace may be used if installed in accordance with the instr...

Страница 25: ...______________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________...

Страница 26: ...l products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause d...

Страница 27: ...TY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased _________________________...