Astria Aries 33 Скачать руководство пользователя страница 49

Operation 

900004-01, 04/2015

Innovative Hearth Products
Astria™ Aries Direct-Vent Gas Fireplaces

49

OPERATION

 WARNING 

Young children should be carefully supervised when they are in the same room as the appliance. 

Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is 

recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install 

an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and 

away from hot surfaces.

 AVERTISSEMENT 

Les jeunes enfants devraient être surveillés étroitement lorsqu’ils se trouvent dans la même pièce que 

l’appareil. Les tout petits, les jeunes enfants ou les adultes peuvent subir des brûlures s’ils viennent en 

contact avec la surface chaude. Il est recommandé d’installer une barrière physique si des personnes 

à risques habitent la maison. Pour empêcher l’accès à un foyer ou à un poêle, installez une barrière de 

sécurité; cette mesure empêchera les tout petits, les jeunes enfants et  toute autre personne à risque 

d’avoir accès à la pièce et aux surfaces chaudes.

 WARNING 

Reinstall any barrier removed before operating the fireplace. The barrier is designed to reduce the risk of 

burns from hot glass. Do not operate the fireplace without the barrier installed.

 WARNING 

Do not operate the fireplace if:
• The glass front is removed, cracked, or broken
• The surround trim assembly and screen are not installed

CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the flu with 

headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Turn off the gas 

supply to the appliance and have it serviced by a qualified professional, as it may not be operating correctly. 

Some people are more affected by carbon monoxide than others, including pregnant women, people with heart 

or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

NOTE: Do not place furniture or other combustible materials within 36” of the front of viewing area(s).
NOTE: Children and adults should be alerted to the hazards of high surface temperature and should stay away to 

avoid burns or clothing ignition.

Remarqué : Les enfants et les adultes devraient être infor-més des dangers que posent les températures de 

surface élevées et se tenir à distance afin d’éviter des brûlures ou que leurs vêtements ne s’enflamment.

NOTE: Installation and repair should be done by a qualified service person. The fireplace should be inspected before 

use and at least annually by a professional service person. More frequent cleaning may be required due to excessive 

lint from carpeting, bedding material, etcetera. It is imperative that control compartments, burners and circulating air 

passageways of the fireplace be kept clean.

Remarqué : L’installation et la réparation devrait être confiées à un technicien qualifié. L’appareil devrait faire 

l’objet d’une inspection par un technicien professionnel avant d’être utilisé et au moins une fois l’an par la suite. 

Des nettoyages plus fréquents peuvent être nécessaires si les tapis, la literie, et cetera produisent une quantité 

importante de pous-sière. Il est essentiel que les compartiments abritant les commandes, les brûleurs et les 

conduits de circulation d’air de l’appareil soient tenus propres.

NOTE: Do not use these fireplaces if any part has been under water. Immediately call a qualified, professional service 

technician to inspect the fireplace and to replace any parts of the control system and any gas control which have 

been under water.

Remarqué : Ne pas utiliser cet appareil s’il a été plongé, même partiellement, dans l’eau. Appeler un technicien qualifié pour 

inspecter l’appareil et remplacer toute partie du système de commande et toute commande qui a été plongée dans l’eau.

Содержание Aries 33

Страница 1: ...e gaz indiqu sure la plaque signal tique Cet appareil ne peut tre converti d autres gaz sauf si une trousse de conversion est utils e Do not store or use gasoline or other flammable vapors and liquids...

Страница 2: ...TRE NON REFROIDIE NE LAISSEZ JAMAIS UN ENFANT DE TOUCHER LA VITRE L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact accidentel avec la vitre chaude et doit tre i...

Страница 3: ...engaalosni osalejadosde lachimeneaenfuncionamiento Superviseenformacercanaalos ni osencualquiercuartodondehaya unachimeneafuncionandopara impedirelcontactoconelvidrio Mantenga la ropa mobiliario gasol...

Страница 4: ...stallation Requirements for the Commonwealth of Massachusetts 10 Cold Climate Insulation 10 Manufactured Home Requirements 11 Location 11 Vent Termination Clearances 12 Minimum Clearances to Combustib...

Страница 5: ...keep toddlers young children and other at risk individuals out of the room and away from hot surfaces Les jeunes enfants devraient tre surveill s troitement lorsqu ils se trouvent dans la m me pi ce q...

Страница 6: ...manual For assistance or additional information consult a qualified installer service agency or the gas supplier AVERTISSEMENT Une installation un r glage une modification une r paration ou un entret...

Страница 7: ...he barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for this appliance For use with barrier s Part No s F1902 33 Models F1839 35 Models F1840 40 Models and F1903 4...

Страница 8: ...lean Remarqu L installation et la r paration devrait tre confi es un technicien qualifi L appareil devrait faire l objet d une inspection par un technicien professionnel avant d tre utilis et au moins...

Страница 9: ...WC 2 61 kPa Propane 11 0 WC 2 74 kPa 13 0 WC 3 23 kPa Table 4 Manifold Gas Supply Pressure Fuel Pressure Natural Gas 3 5 WC 0 87 kPa Propane 10 0 WC 2 49 kPa Test gauge connections are provided on the...

Страница 10: ...ordance with Massachusetts Rules and Regulations 248 C M R Installation and repair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts The flexible gas line connector...

Страница 11: ...cting These direct vent fireplaces are uniquely suited for installations requiring a utility shelf positioned directly above the fireplace Utility shelves like these are commonly used for locating tel...

Страница 12: ...12 to 7 12 1 25 ft 0 38 m 7 12 to 8 12 1 5 ft 0 46 m 8 12 to 9 12 2 0 ft 0 61 m 9 12 to 10 12 2 5 ft 0 76 m 10 12 to 11 12 3 25 ft 0 99 m 11 12 to 12 12 4 0 ft 1 22 m 12 12 to 14 12 5 0 ft 1 52 m 14...

Страница 13: ...corner 6 152 mm minimum 6 152 mm minimum H Clearance to each inside of center line extended above meter regulator assembly 36 910 mm within a height of 15 ft above the meter regulator assembly 36 910...

Страница 14: ...f the unit The fireplace may be located on or near conventional construction materials However if installed on combustible materials such as carpeting vinyl tile or other combustible material other th...

Страница 15: ...length 3 1 2 89 mm 12 305 10 254 8 203 6 152 4 102 2 51 in mm 8 203 10 254 12 305 14 356 16 406 18 457 Hood Fireplace Mantel depth Wall Finishes Surrounds Mantels NOTE Combustible wall finish materia...

Страница 16: ...erify Proper Fireplace Operation Page 39 Finishing 14 Optional Install the Firebox Liners Page 52 15 Traditional Fireplaces Install the Logs Volcanic Stone and Glowing Embers Page 53 16 Contemporary F...

Страница 17: ...fications Corner Installation with Horizontal Termination Model A B C D E F G B A C Inches millimeters D E Back wall of chase enclosure including finishing materials 7 178 Aries CD33 33 3 4 857 51 1 4...

Страница 18: ...or to the area where the appliance is to be installed per requirements outlined in the National Fuel Gas Code NFPA 54 latest edition USA or CAN CGA B149 1 latest edition Canada The gas supply line sho...

Страница 19: ...in direct contact with the nailing flanges and may be located within 1 2 of screw heads and the firebox wrapper in areas adjacent to the nailing flanges Frame the opening to the exact dimensions spec...

Страница 20: ...nt does not have a cap already installed pack inner and outer pipe with the insulation from top Step 5 Remove and discard the large round gasket attached to the back of the unit Install the cap from t...

Страница 21: ...ertical Height ft Vertical Height ft 2 5 Elbow 5 10 15 Base wing Base 6 ft Minimum vertical run 6 ft Minimum vertical run U Shaped Vent Restrictor Inner Fireplace Collar Appliance Top Vent Outlet Figu...

Страница 22: ...desired a 6 x 1 2 screw can be used at the joint but is not required as the pipe will securely lock when twisted Figure 17 Where required a telescopic vent section SV4 5LA may be used to provide the i...

Страница 23: ...465 38 75 0 0 0 0 10 10 69 5 75 0 0 0 2 0 2 475 5 39 625 0 1 0 0 10 11 73 5 6 125 1 0 0 2 0 3 480 40 1 1 0 0 10 12 79 5 6 625 0 1 0 2 0 3 492 41 1 0 1 0 10 12 81 6 75 0 0 0 1 1 2 499 5 41 625 0 0 0 1...

Страница 24: ...and or adjacent walls is specified in ANSI Z223 1 In Canada the current CAN CGA B149 1 installation code by major building codes Always consult your local codes for specific requirements A general gui...

Страница 25: ...Install firestop spacer at ceiling When using Secure Vent use SV4 5VF firestop spacer at ceiling joists when using Secure Flex use SF4 5VF firestop spacer If there is living space above the ceiling l...

Страница 26: ...t top and sides only and trim where necessary Seal the top and both sides of the flashing with waterproof caulking 12 Install the storm collar Install the storm collar supplied with the flashing over...

Страница 27: ...re an elbow is the only vertical component in the system WARNING Do NOT join separate sections of concentric flexible vent pipe Figure 25 Top Vent Straight Table 17 Rear Vent One 90 Elbow Ceiling fire...

Страница 28: ...y vent run with more than 6 ft of vertical rise See Page 21 for more information If 20 ft of H horizontal vent run is needed then 4 ft straight section minimum of V vertical vent will be required This...

Страница 29: ...he minimum clearances for combustibles Page 24 2 Frame the exterior wall opening Locate the center of the vent outlet on the exterior wall Table 11 Cut and or frame an opening 10 1 2 x 12 1 8 267 x 30...

Страница 30: ...Figure 27 13 Install the firestop spacer at the exterior wall When using the square termination install SV4 5HF Secure Vent SF4 5HF Secure Flex Firestop Spacer over the opening at the exterior side of...

Страница 31: ...water infiltration install the firestop spacer SV4 5HF on the exterior side of the wall Figure 28 Venting Connection and Exterior Wall Recessing of the Horizontal Compact Termination SV4 5HTKCT Siding...

Страница 32: ...port straps as necessary NOTE SV4 5VF Secure Vent SF4 5VF Secure Flex firestop spacer must be used any time vent pipe passes through a combustible floor or ceiling SV4 5HF Secure Vent SF4 5HF Secure F...

Страница 33: ...1 524 V H H1 60 ft 18 288 m maximum H 8 ft 2 438 m maximum H H1 25 ft 7 62 m maximum Install the U shaped vent restrictor in any vent run with more than 4 ft of vertical rise See Page 21 for more inf...

Страница 34: ...will be required This table shows a 1 V to 5 H ratio For every 1 ft of V vertical you are allowed 5 ft of H horizontal run up to a maximum horizontal run of 20 ft 6 096 m Table 28 Top Vent Three 90 El...

Страница 35: ...BLACK HIGH TEMPERATURE SEALANT P N 10K81 to the outside surface of both collars of the adaptor fill the grooves of the outer collar to be covered by the flexible pipe and slide the flexible vent over...

Страница 36: ...tions as it was attached to the adaptor Figure 29 NOTE Attach Secure Flex vent to Secure Flex terminations only Do NOT substitute Secure Vent terminations or Secure Vent adaptor for Secure Flex compon...

Страница 37: ...end of each conductor connected to the gas valve circuit and the other end of each conductor placed loose inside the bottom compartment CAUTION In millivolt systems do NOT connect a wall switch to a 1...

Страница 38: ...nd FBK 200 blower kit applications Figure 33 Figure 33 Junction Box Wiring 120 V 60 hz 1 phase Ground green Neutral white 120 VAC black Wall mounted ON OFF blower switch or variable speed control swit...

Страница 39: ...open flame to check for leaks Turn on gas supply and test for gas leaks using a gas leak test solution also known as bubble leak solution NOTE Using a soapy water solution is an effective leak test s...

Страница 40: ...echnician Ensure glass door is in place and sealed during adjustment CAUTION Soot will be produced if the air shutter is closed too much Any damage due to sooting resulting from improperly setting the...

Страница 41: ...r Tube Adjustment Rod Up Fully Closed Position Adjustment Set Screw If air shutter is closed too far Flame will be orange Air shutter gap should be increased If air shutter is open too far Flame will...

Страница 42: ...TE All models must have a barrier installed prior to operation 1 Open the control compartment door Page 51 2 Hold the barrier in front of the glass door and slide it up into the slots above the glass...

Страница 43: ...y spoken in the home If unknown affix the English language label 3 If you are unable to locate the labels please contact IHP or your nearest IHP dealer to receive additional safety instruction labels...

Страница 44: ...acer H2246 Adaptor 74L61 see 750204M 77L81 SV4 5SC6 Storm Collar 6 pack H5817 SV4 5 20SSWSK Rigid Small Square Termination 20 with Shield and Firestop see 750247M and 750204M H6183 SV4 5HF5 Firestop S...

Страница 45: ...1 1 1 spacing 10 Pack 94L07 SFKIT36SS Small Square Termination for flex with 36 914 mm of compressed flex vent see 750204M F1803 SF4 5HTKCT Horizontal Compact Termination for flex without flex 94L08 S...

Страница 46: ...selon les instructions du fabricant fournies avec la trousse Le fournisseur de service qualifi ayant r alis l installation assume les responsabilit s li es la conversion In Canada The conversion shal...

Страница 47: ...em Fireplaces 7 Refer to the instructions provided with the SIT Regulator Conversion Kit and Figure 42 Using a Torx T20 driver with 1 4 shank or slotted screwdriver remove and discard the pressure reg...

Страница 48: ...the burner assembly into its position and secure the trapezoidal plate with the two screws previously removed 14 Reinstall the baffle with the two baffle securing screws 15 Reassemble the remaining co...

Страница 49: ...d by carbon monoxide than others including pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes NOTE Do not place furniture or ot...

Страница 50: ...e home If unknown affix the English language label 3 If you are unable to locate the labels please contact IHP or your nearest IHP dealer to receive additional safety instruction labels free of charge...

Страница 51: ...de door tab Figure 46 out of the tab groove and align it with the vertical slot Figure 45 Figure 45 Control compartment door slots Figure 46 Control compartment door tabs Vertical slot Screw hole Tab...

Страница 52: ...Close the control compartment door Continuous Pilot Ignition Switch Fireplaces with an electronic gas valve have a continuous pilot ignition CPI switch installed in the control compartment This switc...

Страница 53: ...ng to these instructions improper combustion could occur This could result in the excessive production of soot and or the colorless odorless toxic gas carbon monoxide CO NOTE If applicable install the...

Страница 54: ...the entire set H7666 35 Aries and F1885 33 Aries 1 If necessary remove the glass door Page 56 Locate and bend up Burner Locating Tabs Figure 50 2 Locate the log placement brackets Figure 50 Place embe...

Страница 55: ...Log 5 Right Cross Log Catalog number for the entire set Aries 40 H7667 Aries 45 H7840 1 If necessary remove the glass door Page 56 2 Locate the log placement brackets Figure 54 Figure 54 Placing log...

Страница 56: ...duce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed WARNING Une barri re con ue pour r duire le risque de br lure par le hublot chaude est fournie...

Страница 57: ...op channel with the flat side toward the fireplace then swinging the base of the barrier into the brackets and lowering it into place 5 Close the control compartment door Removing the BARRIER 1 Open t...

Страница 58: ...system components However more frequent periodic inspections and cleanings should be performed by the homeowner NOTE Prior to the first use of the fireplace and each burn season and periodically duri...

Страница 59: ...able at your local IHP dealer Never attempt to paint a hot fireplace Do not attempt to repaint the fireplace until the finish is completely cured Burn in Period on Page 51 If the surface becomes stain...

Страница 60: ...e 71 Cleaning the burner Carefully remove the logs media Vacuum out any foreign matter on the burner e g lint carbon etc Ensure the burner ports are free of debris NOTE Improper positioning of logs me...

Страница 61: ...gns of dislocation of the vent components Fireplace Inspection Qualified Service Technician Perform the appropriate fireplace inspection procedure detailed in this manual Replacing Glowing Embers Home...

Страница 62: ...ermal snap switch Glowing Embers and Volcanic Stone Table 43 Glowing Embers and Volcanic Stone Catalog Model Description 88L53 FGE Bag of Glowing Embers 80L42 FDVS Bag of Volcanic Stone Glass Media Ta...

Страница 63: ...teries included H8865 WS S STAT Wall control Catalog Number Large LCD display Shows room and set temperatures in F and C Wall mounted Thermostatic or manual ON OFF operation Connects to wall switch wi...

Страница 64: ...tch Catalog Model 80L41 FRS OFF ON Wall Switch Kit The OFF ON wall switch kit can be used to control the operation of the fireplace burner or blower Install the OFF ON wall switch in a convenient loca...

Страница 65: ...diately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay lit after several tries turn the gas control knob to OFF and call you...

Страница 66: ...ien qualifi ou le fournisseur de gaz Si la veilleuse ne reste pas allum e apr s plusieurs tentatives r glez la manette d admission du gaz la position OFF et appelez un technicien qualifi ou le fournis...

Страница 67: ...l which has been under water Electronic Gas Control Valve SIT Electronic Pilot Assembly 3 Turn off all electric power to the appliance if service is to be performed Note The control may have a battery...

Страница 68: ...erie de secours installer les batteries au besoin 8 Placez l interrupteur du r cepteur en position REMOTE ou l interrupteur mural en position ON 9 Si applicable Appuyez sur le bouton ON OFF pour s lec...

Страница 69: ...ons a Defective pilot generator thermocouple Check pilot flame it must impinge on thermocouple Clean and or adjust pilot for maximum flame impingement on thermocouple Ensure that the connection betwee...

Страница 70: ...e fireplace Check the gas supply and gas shutoff valves b Loose wires to the valve or ignition module Check control compartment for any obviously loose wiring call a service technician if necessary c...

Страница 71: ...illivolt Piezo Igniter 10K86 1 10K86 1 10K86 1 10K86 1 17 Millivolt Piezo Igniter Wire 56L21 1 56L21 1 56L21 1 56L21 1 18 Millivolt Pilot Generator 60J79 1 60J79 1 60J79 1 60J79 1 19 Millivolt Thermoc...

Страница 72: ...res que celles sp cifiquement approuv es avec cet appareil sont utilis es WARNING Never use substitute materials Use of non approved parts can result in poor performance and safety hazards Table 55 Ho...

Страница 73: ...the Product affecting its stability or performance The Product must be subjected to normal use The Product is designed to burn either natural or propane gas only Burning conventional fuels such as wo...

Страница 74: ...yles and products Consult your local distributor for fireplace code information Printed in U S A 2013 2015 Innovative Hearth Products LLC P N 900004 01 Rev G 04 2015 1508 Elm Hill Pike Suite 108 Nashv...

Отзывы: