6

Step 3.

  Keep the combustion air damper and 

the by-pass damper opened for 10 minutes 

before closing it. It will ensure sufficient tem-

peratures for combustor light-off. 
To refuel the Villa Vista™ Series fireplace when 

the unit is still hot (Some burning fuel remaining 

or a glowing combustor)

Step 1.

  Open the by-pass and air controls fully. 

Step 2.

  Open the door approximately 1 inch, 

wait five seconds until the draft is stable and 

then open it completely. Load the fuel, close 

the door and by-pass (temperatures within the 

firebox should be enough to maintain catalytic 

operation).

G.  Poor chimney draft - 

With no fire, there 

should be sufficient draft to exhaust cigarette 

smoke introduced under the baffle.  Chim-

neys installed against an outside wall without 

protection may generate back draft problems 

which will cause start-up problems. To 

prevent this, open a nearby window, roll up 

a piece of paper and light it. 
Then, hold it in the upper part of the firebox 

to warm up the chimney.  Wait until the draft 

is sufficient, then start the fire.

H.   Blower for forced air kit operating  -

 Make 

sure that the blower is at the “off” position 

when you open the fireplace door for reload-

ing.

IMPORTANT CAUTIONS

A. Do not block the hot air vents to the fireplace 

as this will cause the fireplace to overheat.

B. Never use gasoline, gasoline-type lantern 

fuel, kerosene, charcoal lighter fluid, or 

similar liquids to start or ‘freshen up’ a fire 

in this fireplace.  Keep all such liquids well 

away from the fireplace while it is in use.

C. Do not burn coal.  The sulphur in coal will 

corrode the firebox and chimney.

D. Do not burn driftwood which has been in the 

ocean or salt water.  The salt will corrode 

the firebox and chimney.

E. Do not operate the unit with the door partly 

open since this may cause smoke to be 

drawn into the room.

F.  Do not burn wood in the area in front of the 

log retainers.

G. Do not abuse the unit by burning paper, or 

cardboard or construction material such as 

pressed wood, plywood or lumber.

H. Do not allow the wood to smoulder or burn 

without flame, since this will produce exces-

sive creosote in the unit as well as increased 

particulate emissions.

Smoke Detectors Recommended

Since there are always several potential sources 

of fire in any home, we recommend installing 

smoke detectors. If possible, install the smoke 

detector in a hallway adjacent to the room 

(to reduce the possibility of occasional false 

activation from the heat produced by these 

appliances). If your local code requires a smoke 

detector be installed within the same room, you 

must follow the requirements of your local code. 

Check with your local building department for 

requirements in your area.

Carbon Monoxide Monitor Recommended

Carbon Monoxide Poisoning

: Early signs of 

carbon monoxide poisoning are similar to the flu 

with headaches, dizziness and/or nausea. If you 

have these signs, obtain fresh air immediately. 

Some people are more affected by carbon mon-

oxide than others, including pregnant women, 

people with heart or lung disease or anemia, 

those under the influence of alcohol, and those 

at high altitudes.

It is against federal regulations to operate 

wood heaters in a manner inconsistent with 

operating instructions in the manual.

Dealing With A Chimney Fire

Regular chimney maintenance and inspection 

can prevent chimney fires.  If you have a chimney 

fire, follow these steps:

1.  Close the fireplace doors and the combus-

tion air damper.

2.  Alert your family of the possible danger.

3.  If you require assistance, alert your fire 

department.

4.  If possible, use a dry chemical fire extin-

guisher, baking soda or sand to control the 

fire.  Do not use water as it may cause a 

dangerous steam explosion.

5.  Check outside to ensure that sparks and hot 

embers coming out of the chimney are not 

igniting the roof.

6.  Do not use the fireplace again until your 

chimney and fireplace have been inspected 

by a qualified chimney sweep or a Fire 

Department Inspector.

OK

Achieving Clean Burns

Check the exhaust in about 15 to 20 minutes 

(see below). Large amounts of smoke indicate 

an improper burn setting (either too high or too 

low). Adjust and recheck in 5 to 10 minutes.

REFUELING: During the refueling and 

rekindling of a cool fire, or a fire that has 

burned down to the charcoal phase, operate 

the stove at a medium to high firing rate for 

about 10 minutes to ensure that the catalyst 

reaches approximately 600°F.

Smoking – Causes and Troubleshooting

To reduce the likelihood of smoking when 

opening the doors, set the air damper to the 

“accelerated combustion” position and open 

the by-pass damper before opening the doors. 

Your fireplace has been designed and tested 

to provide smoke free operation. Occasionally, 

there may be a small amount of smoking upon 

lighting the fire, until the chimney heats up but 

this should not continue.  If the fireplace does 

continue to smoke, it is probably for one of the 

following reasons:

A.  The door is partly open - 

Open the door 

fully.

B.   Negative pressure in the house - 

As the 

fire burns, air goes up the chimney.  This 

air must be replaced through leakage into 

the house or through the outside air duct.  

When operating the Villa Vista fireplace, 

open a nearby window temporarily to check 

if there is adequate air replacement.

C.  Fans operating (e.g. range hood) - 

These 

fans draw air out of the house and may 

actually cause a negative pressure in the 

house.  Turn off all fans and open a nearby 

window to determine if this is the cause of 

the problem.

D.  Wet wood - 

Wet or tarred wood will smoul-

der and smoke instead of burn properly. 

Your dealer can help you determine if you 

have properly seasoned wood for burning.

E.   Dirty or blocked chimney - 

Check to make 

sure the chimney is clear and reasonably 

clean. If dirty call a certified chimney sweep 

or use a properly sized chimney brush to 

clean.

F.   Chimney not long enough - 

The minimum 

chimney height is 12 feet, not including the 

fireplace height.  The chimney must extend 

at least 3 feet (915 mm) above its point of 

contact with the roof and at least 2 feet (610 

mm) higher than any roof or wall within 10 

feet (3 m) of it. 

Figure 6

Содержание Villa Vista

Страница 1: ...o de la pièce 901003 02 Villa Vista CD Villa Vista CD Villa Vista Villa Vista WARNING This product can expose you to chemicals includ ing Carbon Black which is known to the State of California to cause cancer and Carbon Monoxide which is known to the State of California to cause birth defects or other reproductive harm For more information go to www P65Warnings ca gov Wood Burning Fireplaces P N 9...

Страница 2: ...PARTS REQUIRED Fireplace model Villa Vista Series Louver set See options on Page 22 7 diameter chimney United States Model IHP Snap Pak including Chimney lengths Elbows where necessary Associated components as per these installation instructions and vent manufacturer s instructions 7 diameter chimney Canada Models ASHT S2100 manufacture by Security Chimneys or DuraTech Canada DTC manufactured by D...

Страница 3: ...ems generalconstructionconditions inadequate chimney heights adverse wind conditions and or unusualenvironmentalfactorsor conditions beyond our control WARNING The Villa Vista series fire places must be installed with an outside air kit intake which is included with the fireplace WARNING THE FIREPLACE MUST BE OPER ATED WITH THE DOORS FULLY OPENEDORDOORSFULLYCLOSED IF THE DOORS ARE LEFT PARTLY OPEN...

Страница 4: ...ws the draft air to by pass the catalytic combustor Opening the by pass damper control increases the draft allowing the unit to achieve proper operating temperatures during a cold start up It also provides more draft to prevent smoke spillage when the door is opened Catalytic By Pass Gauge To determine when to close the By Pass the unit is equipped with a gauge see Figure 1 Thegaugeislocatedbehind...

Страница 5: ...includingchimney length and the moisture content of the wood This method of burning should be used only after operating the Villa Vista series fireplaces with the air control opened to produce a hot fire for about an hour Slow combustion can be used at night in order to reduce the heat output and prolong the burn The loading time will be between 6 10 hours Be aware that the glass will get dirty us...

Страница 6: ...ant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes It is against federal regulations to operate wood heaters in a manner inconsistent with operating instructions in the manual Dealing With A Chimney Fire Regular chimney maintenance and inspection canpreventchimneyfires Ifyouhaveachimney fire follow these steps 1 Close the fireplac...

Страница 7: ...r operation will prevent chimneyfires Keepyourchimneyclean Donot allow more than 1 16 creosote build up in your chimney The amount of creosote will depend on variables such as frequency of use and type of fire We recommend that you FUEL What does Well Seasoned mean When a tree is cut down the wood is green full of sap and moisture This moisture content can exceed 80 which must be reduced to less t...

Страница 8: ... open and partially closed position after a hot fire has been started Burn hardwoods Masking Soot See Photo 8 Combustor has not maintained a light off Burning coal will cause a sulfur based compound to coat the catalyst Place combustor in a partially open and partially closed position after a hot fire has been started to burn off the soot accumulation Revert to burning wood and fire the combustor ...

Страница 9: ...o 6 Fly Ash Photo 7 Creosote Plugging Photo 8 Soot Masking These conditions are primarily related tosuchfactorsasdraft agingorfailure of the appliance components aging or fatigue of the combustor flue in stallation using the wrong fuel or to improper operation of the appliance Following the appliance s operating manual will prevent these conditions Figure 9 ...

Страница 10: ...ssashes Leaveanashbed approximately1inchdeeponthefireboxbottom to help maintain a hot charcoal bed Remove ashes only when the fire is out and the ashes are cold 24 to 48 hours after the fire is out Open the bottom louver and the doors lift the door trap lever remove the plug on the doortrapoftheashtrayusingglovesorapoker Sweep the ashes in the opening with a brush or any similar tool Reinstall the...

Страница 11: ...SCREWS GASKET ADJUSTEMENT SCREW DOOR HINGE SCREWS Figure 12 DO NOT USE CHEMICAL GLASS CLEANERS ON PAINTED SURFACES AS IT MAY CAUSE THE PAINT TO PEEL CAUTION DONOTALLOWWINDOWCLEANER TO GET IN CONTACT WITH DOOR GASKET OR PAINT ON FACADE OR DOOR ONCE CLOSED CONTACT OF GLASS CLEANER WITH THE FIREPLACE FACADE CAN PROVOKE PAINT PEELING OFF Gasket Replacement Remove the door from the unit and lay it on a...

Страница 12: ...a Vista series fireplaces may be installed directly on a combustible floor The supplied safety metal strip must be positioned as follows One half under the front of the fireplace and the other half must extend on the floor over which the hearth extension will be built see Figure 13A The safety metal strip must cover the entire width of the fireplace The combustible floor in front of the fireplace ...

Страница 13: ...re nottoscale consultinstallationinstructions Product designs materials dimensions specifications colors and prices are subject to change or discontinuance without notice All framing dimensions calculated for 1 2 dry wall at the fireplace face If sheathing the chase or finishing with other thickness materials calculationswill needtobemade The fireplace must not be in contact with any insulation or...

Страница 14: ...ust not be in contact with the fireplace or in theenclosureframeasdescribedin Enclosure section NOTE Localcodesmaynotrequirefirestopping at the ceiling levels for outside chase installa tions However it is recommended for safety and the reduction of heat loss WARNING Ifinsulationisused thefireplace must not be placed directly against it Insulation or vapor barriers if used must first be covered wi...

Страница 15: ...38 and a height of 54 from the base of the appliance see Figure 19 3 Non combustible materials such as brick stone or ceramic tile may project in front of and onto the fireplace facing see Figure 18 2 x 3 MIN 54 1 2 GYPSUMBOARD SPACER MANTEL Figure 18 2 x 3 MIN SPACER 1 2 GYPSUMBOARD NON COMBUSTIBLE FACING Figure 19 COMBUSTIBLE CAN NOT PROJECT OVER OR IN FRONT OF THE FIREPLACE 38 54 Mantel The man...

Страница 16: ...e in the outside wall of the house at the chosen location From outside place the outside air register in the hole open side down and fasten the register to the wall with screws as shown see Figure 20 Slip the pipe into the insulated sleeve Place the insulated pipe over the register tube and over the fireplace s outside air connector see Figure 21 At each end carefully pull back the insulation and ...

Страница 17: ...Kit Table 3 TOOLS NEEDED 5 16 hex driver and no 2 Phillips screwdriver GENERAL INFORMATION If you encounter any problems need clarification of these instructions or are not qualified to properly install this kit contact you local distribu tor or dealer Readthisinstructionsheetinitsentiretybeforebeginningtheinstallation ALL WARNINGS AND PRECAUTIONS IN THE INSTALLATION AND OPERATION MANUAL PROVIDED ...

Страница 18: ...e and outlet locations prior to ducted flex kit installation 2 Remove the two 8 diameter cutouts on top of the fireplace Then cut the insulation in order to obtain two 8 diameter openings and remove the insulation 3 On the duct adaptor bend the appropriate tabs down so that the bottom of the adaptor is just below the bottom of the insulation 4 Align the collar slots with the holes in the adaptor f...

Страница 19: ...1 7m with the minimum distance from the center of outlet to the ceiling and for the center of the outlet to a side wall of 11 279mm Do not connect the hot air ducts to a central heating system Use only IHP grills and components as described in this manual Ensure that the flex insulation and sheathing do not touch the flue pipe Never allow the pipe to pitch downwards Never route the piping downward...

Страница 20: ...ce expands This can be achieved by having the chimney supported by the supports The maximum chimney length that can be supported by the fireplace is nine 9 feet 2 75 m 6 The chimney must extend at least 3 feet 915 mm above its point of contact with the roof and at least 2 feet 610 mm higher than any wall roof or building within 10 feet 3m of it see Figure 21 7 If the chimney extends higher than 5 ...

Страница 21: ...llation and Termination sections B A Framing lumber of equal size to the joist should be used Figure 28 FEMALE END MALE END BUTTON LOCK ATTACH FOR LOCK Figure 29 INSULATION SHIELD CAT NO SPIS NAIL FIRESTOP CAT NO SPFS Chimney Flue Diameter 7 A 13 7 16 B 13 7 16 Table 4 If the area above the ceiling is an attic go to step 5 2 Install SNAP PAK chimney sections start ing at the top of the appliance L...

Страница 22: ...d the adaptor on wall support to maintain 2 clearance to combustibles AT THIS POINT TIGHTEN CLAMPS 11 Slide IHP chimney pipe into top of tee Align male and female ends Push down on pipe sec tions until locked As sections are added it will be necessary to secure them to the outside wall with bands SPWB at eight foot intervals and 2 from combustibles Wall Bands SPWB are secured to the chimney by pla...

Страница 23: ...roof will vary depending on the roof pitch 2 Install the next SP chimney section through the roof See Figure 34 NOTE If your roof is already shingled be sure to slide the upper edge under the shingles to prevent leakage 3 Install a bead of caulk around the pipe at the top edge of the flash ing Wrap the storm collar around the pipe and imbed the edge in the caulk to prevent leakage around the pipe ...

Страница 24: ...operation Trees buildings adjoining roof lines adverse wind conditions etc may create a need for a taller chimney should smoking occur Additional support is required above the roof if the chimney height exceeds four 4 feet Select the proper support for your application using either a roof brace Figure 38 or a support band with guy wires Figure 39 Figure 36 IF 10 FEET OR LESS L944 FIG21 THEN BUT MU...

Страница 25: ...8 460 mm 18 460 mm 16 410 mm Figure 40 Chimney Adaptor Canada only CHIMNEY ADAPTOR CANADA ONLY The fireplace is normally supplied with a chimney adaptor suitable for use with IHP SnapPak venting In Canada the use of Security Chimneys ASHT adaptor is required Security part number 7IHP1 or 7IHP2 One inch wall Two inch wall CANADA ONLY CHIMNEY INSTALLATION INSTRUCTIONS USING SECURITY CHIMNEYS ASHT CA...

Страница 26: ...sonry chimney at 30º 3 Increase the size of the hole until a 30º liner elbow can be easily slipped through 4 Slide the liner down from the top of the masonry chimney until you reach the hole level 5 Slip through the hole a 30º liner elbow and connect it to the liner 6 Add a small liner section to the liner elbow which will allow the liner to extend at least 12 measured at the top of the liner from...

Страница 27: ...t Part No Blower UZY5 Blower Motor Speed Control VRUW Outside Air Kit Required Included with Fireplace Outside Air Coupler to Connect Outside Air UZI to Fireplace UZIAD UZIAD Outside Air Ducting Includes 4 in Insulated Flex x 10 ft long UZI UZI Central Forced Air Kit Accessories Central Forced Air Kit Central forced air kit including blower BISZY flex adaptor BISAF 2 clamps variable speed control ...

Страница 28: ...ondary Air Tube rear PR SR2051 Log Retainer Bar PR SR2323 Touch up Paint Aerosol Black Metallic SBMB6309 H8159 Blower 250 CFM for central forced air kit BISZY BISZY Blower variable speed control with decorative wall plate for BISZY VRUW VRUW Thermo disk on off blower control for BISZY VTU VTU Blower to flexible pipe adaptor BISAVF BISAVF Backdraft damper BISBD BISBD Fireplace to Flex adaptor and 2...

Страница 29: ...r ordering information DuraTech DTC 1 High Temp Insulated Stainless Steel Chimney 7 I D and 11 O D Double Wall Stainless Steel Listed to CAN UCL S604 UL 103HT and CAN ULC S629 Description Part Cat No Lengths and Misc Chimney Components 8 length 7 Dia 7DTC 08SS 12 length 7 Dia 7DTC 12SS 18 length 7 Dia 7DTC 18SS 24 length 7 Dia 7DTC 24SS 36 length 7 Dia 7DTC 36SS 48 length 7 Dia 7DTC 48SS Adjustabl...

Страница 30: ...ON REMPLACER LA VITRE AVEC UN VERRE CÉRAMIQUE DE 5mm D ÉPAISSEUR POUR UNE UTILISATION SÉCURITAIRE INSTALLER CONFORMÉ MENT AUX DIRECTIVES DU FABRICANT ATTENTION NE PAS OBSTRUER LES ARRIVÉES D AIR COMBURANT NE PAS FAIRE SURCHAUFFER LE FOYER LA PORTE DU FOYER DOIT DEMEURER TOTALEMENT OUVERTE OU TOTALEMENT FERMÉE LORSQUE LE FOYER FONCTIONNE NE PAS UTILISER DE POÊLE ENCASTRABLE OU D AUTRES PRODUITS NON...

Страница 31: ...ATION REMPLACER LA VITRE AVEC UN VERRE CÉRAMIQUE DE 5mm D ÉPAISSEUR POUR UNE UTILISATION SÉCURITAIRE INSTALLER CONFORMÉ MENT AUX DIRECTIVES DU FABRICANT ATTENTION NE PAS OBSTRUER LES ARRIVÉES D AIR COMBURANT NE PAS FAIRE SURCHAUFFER LE FOYER LA PORTE DU FOYER DOIT DEMEURER TOTALEMENT OUVERTE OU TOTALEMENT FERMÉE LORSQUE LE FOYER FONCTIONNE NE PAS UTILISER DE POÊLE ENCASTRABLE OU D AUTRES PRODUITS ...

Страница 32: ..._______________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________...

Страница 33: ...er may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry seasoned wood only c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting from faul...

Страница 34: ...TS See Page 28 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 The de...

Отзывы: