Safety .............................................................................................2

Specifications .................................................................................4

Fireplace Installation ......................................................................5

Venting Installation ........................................................................7

Optional Gas Line Installation ......................................................12

Operation and Maintenance .........................................................13

Replacement Parts .......................................................................14

Technical Service .........................................................................14

Important Notices - Canada  ........................................................15

Parts ............................................................................................16

Accessories ..................................................................................18

Draft Smoke Guidelines - Appendix A  .........................................21

Warranty ......................................................................................23

Thank you for your purchase. We appreciate your 

business!

Please carefully read and follow all instructions in this manual. 

Pay 

special attention to all warnings and safety information.

Following these safety, care, and operation instructions will help 

ensure many years of dependable and enjoyable service from your 

fireplace.

Please read and understand these instructions before installing 

or operating.

SAFETY

 WARNING: Improper installation, adjustment, 

alteration, service or maintenance can cause injury, 

property damage or loss of life. Refer to this manual 

for assistance or additional information. Consult a 

qualified installer or local distributor.

IMPORTANT: Check local codes before installing this 

fireplace.

Before beginning installation of this fireplace, read these instructions 

through completely.
•  This INNOVATIVE HEARTH PRODUCTS, LLC (IHP) fireplace and 

its components are safe when installed according to this installa-

tion manual. Unless you use IHP components, which have been 

designed and tested for the fireplace system, you may cause a fire 

hazard.

•  The IHP warranty will be voided by and IHP disclaims any respon-

sibility for the following actions.

a. Modification of the fireplace, components, doors, air inlet 

system and damper control.
b. Use of any component part not manufactured or approved by 

IHP in combination with an IHP fireplace system.

Proper installation is the most important step in ensuring safe and 

continuous operation of the fireplace. Consult the local building codes 

as to the particular requirements concerned with the installation of 
all factory built fireplaces.

NOTICE: The firebox canopy (hood) must not be modi-

fied or replaced with a canopy that may be provided 

with the unvented decorative room heater.

 WARNING: Do not install a fireplace insert in this 

box unless the manufacturer's instructions with the 

insert specifically state this fireplace has been tested 

for use with this insert.

TABLE OF CONTENTS

FOR YOUR SAFETY

•  Do not store or use gasoline or any other flammable 

vapors or liquids in the vicinity of this or any other 

appliance.

•  Due to high temperatures, the appliance should be 

located out of traffic and away from furniture and 

draperies.

•  Do not place clothing or other flammable materials 

on or near the appliance.

• Never leave children unattended when a fire is 

burning in the fireplace.

 WARNING: Use solid wood or processed solid 

fuel fire logs only. "Do not poke or stir the logs while 

they are burning. Use only firelogs that have been 

evaluated for the application in fireplace and refer to 

firelog warnings and caution markings on packaging 

prior to use."

This fireplace is not intended to be used as a sub-

stitute for a furnace to heat an entire home. Use for 

supplemental heat only.

Overfiring of a fireplace is a condition where exces-

sive temperatures are reached, beyond the design 

capabilities of the appliance. The damage that occurs 

from overfiring is not covered under the manufacturer’s 

limited warranty.

Содержание Tuscan42P2

Страница 1: ...as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L autorité compétente comme le service municipal du bâtiment les pompiers etc doit être contacté avant l installation afin de déterminer la nécessité d obtenir un permis This appliance may be installed in an aftermarket permanently located manufac...

Страница 2: ...system and damper control b Use of any component part not manufactured or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Consult the local building codes as to the particular requirements concerned with the installation of all factory built fireplaces NOTICE The firebox canopy hoo...

Страница 3: ...ignificanthazard IMPORTANT See appendix A page 21 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide Poisoning Early signs of carbon monoxidepoisoningresemblethefluwithheadaches dizziness or nausea If you have these signs get fresh air a...

Страница 4: ... 2 572 mm INNER DIA 12 3 8 315 mm 5 8 16 mm 36 915 mm 48 1220 mm OUTER DIA 15 381 mm 24 610 mm 8 204 mm 42 1067 mm 41 1042 mm 48 1067 mm 3 4 19 mm AIR SPACE BACK AND SIDES GAS LINE KNOCK OUTS GAS LINE KNOCK OUTS ELECTRICAL OUTLET RIGHT SIDE LEFT SIDE AIR KIT KNOCK OUT 6 3 4 172 mm 10 5 8 270 mm 12 5 8 321 mm 10 5 8 270 mm 14 1 4 362 mm 16 1 4 413 mm 12 305 mm 8 1 8 207 mm 2 1 2 64 mm 29 1 2 750 mm...

Страница 5: ... Installation The minimum height of the chimney measured from the base of the fireplace to the flue gas outlet of the termination is 8 feet minimum of 4 feet of chimney pipe sections required for outdoor installation Figure 1 Framing Dimensions Figure 2 Corner Installation FRAMING 1 Frame opening for fireplace using dimensions shown in Figures 1 and 2 Note When the fireplace is framed the header h...

Страница 6: ...floor construction in front of fireplace Fab ricate a hearth extension using a material which meets the following specifications a layer of noncombustible inorganic material having a thermal conductivity of k 84 BTU IN FT2 HR F or less at 1 thick For example if material selected has a k factor of 0 25 such as glass fiber the following formula would apply 0 25 x 1 0 0 30 thickness required 0 84 The...

Страница 7: ...2 18 24 36 and 48 snap lock double wall pipe segments planned for maximum adaptability to individual site requirements Actual lengths gained after fitting overlaps must be taken into consideration lineal gain and are given in lineal gain chart see Figure 6 Lineal gain is actual measurable length of a part after two or more parts are connected Figure 6 Lineal Gain Hemmed End 8 Stainless Inner Pipe ...

Страница 8: ... a vertical chimney pipe supported ONLY by the fireplace must not exceed 20 feet Chimney heights above 20 feet must be supported USING ELBOW OFFSET 30E 12DMO 8DMR To clear overhead obstructions you may offset your chimney system using 30E 12DMO 8DMR 30 Offset return elbow A section or sections of chimney may be used between offsets and return elbow Transition pipe must be used after elbow offset i...

Страница 9: ...2 3 4 1 1 1 38 1 2 75 1 2 1 1 3 39 1 4 76 3 4 1 1 1 1 41 1 2 80 1 2 1 1 2 1 42 1 4 81 3 4 1 1 1 1 44 1 2 85 3 4 1 1 1 1 1 45 1 4 87 1 1 1 1 47 1 2 91 1 1 2 1 48 1 4 92 1 4 1 1 2 49 3 4 94 3 4 1 1 2 1 1 52 98 3 4 1 1 1 4 53 1 2 101 1 4 1 1 1 2 54 1 4 102 3 4 1 1 1 1 55 3 4 105 1 4 1 1 3 1 56 1 2 1061 2 1 1 1 2 58 3 4 110 1 2 1 1 2 2 59 1 2 111 3 4 1 1 1 1 1 60 1 4 113 1 1 2 61 3 4 115 3 4 1 1 1 1 2...

Страница 10: ...lete separation from one floor space to an other or attic space as required by most codes When double wall pipe passes through a framed opening into an attic space firestop must be placed into an attic floor as shown in Figure 11 Figure 10 Firestop Spacer with Living Space Above Ceiling Figure 11 Firestop Spacer with Attic Space Above Ceiling IMPORTANT NOTICE When penetrating a ceiling into an att...

Страница 11: ...ipe and slide down until it is snug against open edge of flashing see Figure 14 Use SC1 for all round termina tions Apply waterproof caulk around perimeter of collar to provide a proper seal Figure 14 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Terminations Spark Arrestor Fireplace system must be terminated with listed round top or chase terminations In any case refer to insta...

Страница 12: ...aised platform add height Provide sufficient gas line into fireplace chamber for fitting OPTIONAL GAS LINE INSTALLATION Figure 18 Typical Residential Installations VENTING INSTALLATION Continued connection see Figure 20 page 13 Note Secure incoming gas line to wood framing to provide rigidity for threaded end 4 Repack insulation around gas line and into sleeve opening Seal any gaps between gas lin...

Страница 13: ...NING FIREPLACESEQUIPPEDWITHDOORS SHOULD BE OPERATED ONLY WITH DOORS FULLY OPEN OR DOORS FULLY CLOSED IF DOORS ARE LEFTPARTLYOPEN GASANDFLAMEMAYBEDRAWN OUT OF THE FIREPLACE OPENING CREATING RISKS OF BOTH FIRE AND SMOKE WARNING Discontinue use of the appliance imme diately if doors are damaged and contact a qualified installer for repair Only doors certified with the appliance shall be used WARNING ...

Страница 14: ...ng guidelines instructions and warranty informa tion please refer to your homeowner s guide or contact your dealer Access Panel OPEN CLOSE Damper Handle Outside Air Kit Handle Keyway Slot Handle Retainer REPLACEMENT PARTS See Pages 16 to 18 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer...

Страница 15: ...T 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Support For Use With Chimney Heights In Excess of 30 F0888 RT 8HT Hi Temp Round Top with Mesh Screen F0889 RTT 8HT Hi Temp Round Top with Mesh Screen and Slip Sec tion F0890 RLT 8HT Hi Temp Round Top with Louvered...

Страница 16: ...s com 127051 01_E 16 PARTS WOOD BURNING FIREPLACE MODELS 9 24 16 31 25 16 4 30 32 19 12 23 20 28 17 8 1 5 21 2 18 11 14 3 13 22 10 6 35 29 7 33 34 26 27 15 MODEL NO CATALOG NO Tuscan42P2 F0542 Tuscan42P3 F0543 ...

Страница 17: ...Liner 1 11 See Page 18 Rear Refractory Brick Liner 1 12 See Page 18 Bottom Rear Refractory Brick Liner 1 13 See Page 18 Bottom Front Refractory Brick Liner 1 14 J3972 Firebox Support Leg 4 15 Damper Can Collar 1 16 J8013 Kit Screen Assembly 1 17 Firebox Top Assembly 1 18 J3980 Air Kit Door Assembly 1 19 Face Weldment 1 20 J4471 Air Deflector 1 21 Fireplace Top Insulation 1 22 Access Panel 1 23 J45...

Страница 18: ... J4508 Bottom Front Refractory White Brick 1 PARTS WOOD BURNING FIREPLACE MODELS TUSCAN42P2 AND TUSCAN42P3 Rear Left Side Front Bottom Bottom Right Side MODEL NO CATALOG NO Tuscan42P2 F0542 Tuscan42P3 F0543 ACCESSORIES REFRACTORY STAIN KITS Use the refractory stain kits to give white refractory panels a new look Kit includes foam roller handle paint tray and one can of stain Available stain colors...

Страница 19: ...ection Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock 30 OFFSET AND RETURN F0900 30E 8DM 30 Degree Offset and Return F0886 30E 8HT 30 Degree Hi Temp Offset and Return F1908 30E 12DMO 8DMR 30 Elbow Set 12 to 8 Craftsman 42 F2199 30E 12H...

Страница 20: ...on F0923 ETLO 8DM Square Top with Mesh and Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SLIP SECTION F0923 ETLO 8DM Square Top with Mesh and Slip Section STAINLESS STEEL HOOD Required when installing a vent free gas log in this fireplace F1053 HS42 42 Stainless Steel Hood w 4 Brow DRAIN PAN F1090 DP42 Drain Pan FIRESTOP THIMBLE F0911 ...

Страница 21: ...ing the proper venting system for your installation American National Standards Institute ANSI NFPA 211 Standard for Chimneys Fireplaces Vents and Solid Fuel Burning Appli ances See Draft Section A chimney or vent shall be so designed and constructed to develop a flow sufficient to completely remove all flue and vent gases to the outside atmosphere The venting system shall satisfy the draft requir...

Страница 22: ...The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of the unit for the hearth extension and the mantel and taking into consideration the location of the hot air ducts some models outside air kit and chimney Ifpossible youshouldchoosealocationwherethechimneywi...

Страница 23: ...or propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with th...

Страница 24: ...01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2013 Innovative Hearth Products LLC P N 127051 01 Rev E 05 2017 1508 Elm Hill Pike Suite 108 Nashville TN 37210 ...