Astria Fireplaces SIRIUS42TEN Скачать руководство пользователя страница 2

INNOVATIVE HEARTH PRODUCTS  •  CONTEMPORARY LINEAR VIEW DIRECT-VENT GAS FIREPLACE  •  REQUIRED AND OPTIONAL ACCESSORIES

2

Printed in U.S.A.

© 2015 INNOVATIVE HEARTH PRODUCTS, LLC

P/N  900079-08  Rev. NC   03/2015

P900079-08

NOTE: DIAGRAMS AND ILLUSTRATIONS ARE REPRESENTATIVE AND ARE NOT DRAWN TO SCALE.

1508 Elm Hill Pike, Suite 108 

Nashville, TN 37210

IHP.us.com

Step 2. 

Installing the gas shut-off valve; 

a.

 Pull gas flex line out from inside, beneath fireplace 

floor. 

b. 

Place shut-off valve in valve bracket, threading flex 

line through gap in back. 

c. 

Use coupler to attach additional flex line to shut-off 

valve. 

d. 

Bend up tab on the side of valve bracket to hold 

shut-off valve in place (Figure 3). 

e. 

Attach valve bracket to unit with two screws. 

f. 

Attach shut-off valve to incoming gas line with field-

supplied coupler. 

 

Figure 3: Gas Shutoff Valve Bracket

Step 3. 

Place unit in wall framing. 

 

NOTE: 

The provided non-combustible fiber board 

may be faced with any NON-combustible finish 

material appropriate for use (brick, tile, stone, high-

temperature paint, etc.). For painted wall finish, use 

two (2) coats of quality primer and high-temperature 

paint on provided fiber board. 

Step 4. 

Secure nailing flanges to wall framing. 

Step 5. 

Secure heat shield to top front of unit with two screws. 

 

NOTE: Refer to the Instruction Manual (P/N 

900079-02 for finishing details. 

Step 6. 

Place insulation flat across the top of the fireplace 

lengthwise behind heat shield. 

Step 7. 

Cut noncombustible fireboard to size and install 

flush with top of frame pieces. 

Step 8. 

Finish out wall with ½” finishing materials – paint 

with high-temperature paint, etc. 

Step 9. 

Attach surround in frame using screws a minimum 

of six at specified locations (Figure 2). 

Step 10. 

Install barrier mounting brackets on side of 

surround. 

Step 11. 

If removed, reinstall door and secure with three 

screws. 

Step 12. 

Install Gas Shutoff Valve Door (Figure 1). 

Step 13. 

Install barrier on barrier mounting brackets.

Figure 4: Attach the Surround to the Fireplace

Gap 

(thread 

flex 

gas line 

here)

Back Side

Tab (bend up 

to hold valve)

f i r e - p a r t s . c o m