NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.

5

COLD CLIMATE INSULATION

For cold climate installations, seal all cracks 

around the appliance with noncombustible 

material and wherever cold air could enter 

the room. It is especially important to insulate 

outside cavities between studs and under floor 

on which the appliance rests, if floor is above 

ground level.  Gas line holes and other openings 

should be caulked with high temperature caulk 

or stuffed with unfaced fiberglass insulation. If 

the fireplace is being installed on a cement slab, 

in cold climates, a sheet of plywood or other 

raised platform can be placed underneath to 

prevent conducting cold up into the room. It 

also helps to sheetrock inside surfaces and tape 

for maximum air tightness and caulk firestops.

NOTE: The following requirements reference 

various Massachusetts and national codes 

not contained in this document.

Requirements for the Commonwealth 

of Massachusetts

These appliances are approved for installation 
in the US state of Massachusetts if the following 
additional requirements are met:

•    Un-vented Room Heaters shall be installed 

in accordance with 527 CMR 30.

•     Installation and repair must be done by a 

plumber or gas fitter licensed in the Com-

monwealth of Massachusetts.

•     The flexible gas line connector used shall 

not exceed 36 inches (92 centimeters) in 

length.

•     The individual manual shut-off must be a 

T-handle type valve.

•     Unvented appliances may NOT be installed 

in bedrooms or bathrooms.

•      A working smoke detector must be installed 

in the area where vent-free appliances are 

installed.

Seller of unvented propane or natural gas-fired 

supplemental room heaters shall provide to 

each purchaser a copy of 527 CMR 30 upon 

sale of the unit.

Not to Scale

Figure 1

      

 

CAUTION

Do not install in the vicinity where 

gasoline or other flammable liq-

uids may be stored. The Vent-Free 

firebox must be kept clear and free 

from these combustible materials.

     

  

WARNING

Do not use a blower insert, heat 

exchanger insert or other acces-

sory not approved for use with this 

appliance.

     

  

WARNING

Do not install these built-in Vent-

Free fireboxes in sleeping quarters, 

or in recreational vehicles.

      

 

WARNINGS

Do not install these appliances:

• 

 

Where curtains, furniture, cloth-

ing or other flammable objects 

are less than 42" from the front 

of the Vent-Free room heater.

• 

 

In high traffic areas.

• 

 

In windy or drafty areas.

LOCATION OF FIREBOX

This firebox may only be installed in a bedroom 

when equipped with a listed vent free log set 

of 10,000 BTU input or less.

Carefully select the best location for installation 

of your built-in Vent-Free firebox. The following 

factors should be taken into consideration:

  Clearance to side wall, ceiling, woodwork 

and windows.

  Location must not be affected by drafts 

caused by kitchen exhaust fans, return air 

registers for forced air furnaces/air condi-

tioners, windows or doors.

  Installation must provide adequate ventila-

tion and combustion air.

  Do not install this firebox in a bathroom.

  Location should be out of high traffic areas 

and away from furniture and draperies due 

to heat from firebox.

•  Never obstruct the front opening of the Vent-

Free firebox or restrict the flow of combustion 

and ventilation air.

•  Minimize modifications to existing construc-

tion.  See 

Figure 1

  for location suggestions.

  

  

WARNING

FIRE, EXPLOSION, AND ASPHYXI-

ATION HAZARD

Improper adjustment, alteration, 

service, maintenance, or instal-

lation of this heater or its controls 

can cause death or serious injury.

Read and follow instructions and 

precautions in User’s Information 

Manual provided with this heater.

Содержание ORION32ZB6

Страница 1: ...32ZB6 ORION32ZP2 ORION36ZB6 ORION36ZP2 ORION42ZB6 ORION42ZP2 WARNING If the information in this manual is not followed exactly a fire or explosion may resultcausingpropertydamage personalinjury or loss of life FOR USE ONLY WITH A LISTED GAS FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO EXCEED 40 000 BTU H DO NOT BUILD A WOOD FIRE WARNING IMPROPER INSTALLATION ADJUST MENT ALTERATION SERVICE OR MAINT...

Страница 2: ... by a qualified service person The heater should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpet ing bedding material etc It is important that control compart ments burners and circulating air passageways of the heater be kept clean Allow the heater to cool before servicing Always shut off any e...

Страница 3: ...NSTRUCTIONS BEFORE BEGIN NING YOUR INSTALLATION Packaging List Vent Free Gas Firebox Hood Installation and Operation Instructions GENERAL INFORMATION TheseVent Freefireboxenclosuresaredesigned toacceptallANSIZ21 11 2approvedDecorative TypeVent FreeGasLogRoomHeaters Forthe appropriate Vent Free Gas Log Room Heater model refer to Page 16 see Vent Free Gas Log Sets Refer to the installation instructi...

Страница 4: ...as a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space Rooms com municating directly with the space in whic...

Страница 5: ...a copy of 527 CMR 30 upon sale of the unit Not to Scale Figure 1 CAUTION Do not install in the vicinity where gasoline or other flammable liq uids may be stored The Vent Free firebox must be kept clear and free from these combustible materials WARNING Do not use a blower insert heat exchanger insert or other acces sory not approved for use with this appliance WARNING Do not install these built in ...

Страница 6: ...ulating models RECOMMENDATION Use high temperature finish material for the mantels Clearances Ensure the minimum clearances shown in Figures 2 through 4 are maintained Left and right clearances are determined when facing the front of the firebox Follow these instructions carefully to ensure safe installation Failure to follow these requirements may create a fire hazard Combustible Side Clearances ...

Страница 7: ...such as carpeting vinyl tile etc a metal or wood barrier covering the entire bottom surface must be used Combustible Mantel and Trim Clearance Orion Models WITH Hood Installed Hood is required on all installations for these models sEXAMPLE If you choose to install a mantel that projects 5 you will need to install it so that the bottom of the mantel and trim is approximately 13 or more above Firebo...

Страница 8: ...different sequence Step 1 Position firebox prior to framing or into prepared framing Step 2 Field wire the main power supply to the appliance if a blower kit is to be installed at the time of installation or a later date An optional junction box kit and blower kit is required seePage16 fororderinginformation Followtheinstallationandwiringinstructionson Pages 12 through 14 Electrical connections sh...

Страница 9: ...ce If a wall covering such as drywall is to be attached to the rear wall then the depth must be measured from the drywall surface It is important that this dimension be exact Step 2 Level the firebox by checking the top edge of the firebox Shim if necessary Step 3 Fireplace should be secured to side framing members using the full length nailing tabs at the top and bottom of the fireplace front fac...

Страница 10: ...1061 37 1 4 947 23 1 2 597 20 508 3 77 7 3 8 188 15 7 8 404 7 1 2 191 12 305 1 3 8 35 5 1 2 140 30 3 8 772 29 5 8 753 ORION42ZB6 ORION42ZP2 42 1067 24 610 47 3 4 1213 37 1 4 947 29 1 2 749 20 508 3 77 7 3 8 188 15 7 8 404 7 1 2 191 12 305 1 3 8 35 5 1 2 140 30 3 8 772 29 5 8 753 Dimensions are to assist you in selecting a log set that is a compatible size Interior Firebox Dimensions Firebox Model ...

Страница 11: ...n and rod assemblies see Figure 10 Framing Dimensions Opening ORION32ZB6 ORION32ZP2 ORION36ZB6 ORION36ZP2 ORION42ZB6 ORION42ZP2 A 38 1 4 972 42 1 4 1073 48 1 4 1226 B 40 1 4 1022 40 1 4 1022 40 1 4 1022 C 19 5 8 499 23 5 8 600 29 5 8 753 D 10 1 4 260 12 1 4 311 15 1 4 387 E 59 3 4 1518 63 3 4 1619 69 3 4 1772 F 29 7 8 759 31 7 8 810 34 7 8 886 G 20 1 2 521 20 1 2 521 20 1 2 521 H 42 1 4 1073 45 11...

Страница 12: ...ariable Speed Control Switch Ground HOT SIDE OF RECEPTACLE A ON OFF Wall Switch is used with the FBK 100 kit field provided A Variable Speed Control provided is usedwiththeFBK 200kit Theinstallationofthesekits also require a Junction Box Electrical Kit provided NOTE If any of the original wire as supplied must be replaced it must be replaced with type AWM 105 degree C 14 gage wire Neutral White 12...

Страница 13: ... Figure 16 Step3 Looselytieaknotinthepowercordtotakeupslack seeFigure19 Step 4 Locate the tabs shown in Figure 20 Position the blower assembly so that the tabs located on the cabinet base are seated in the notches of the blower bracket Bend the tabs over to secure the blower assembly see Figure 21 Step 5 Plug power cord into the electrical outlet as illustrated in Figure 13 J Box Flanges J Box and...

Страница 14: ...s The strain relief bushing not supplied should be pressed into the knock out on J box cover around the Romex thiswillprovideprotectiontothewiresandpreventsstrain against connections from J box See Wiring Diagram Figure 14 Install the cover plate over J Box opening on appliance as shown in Figure 22 NOTE Wire connections should be positioned inside of the ap pliance Romex is a plastic insulated wi...

Страница 15: ...Extension combustibles allowed No carpet or vinyl Combustible Platform SIDE VIEW Firebox Floor Combustible Wall Figure 23 Raised Hearth Extension Non Combustible Wall see Figure 4 Fireplace Opening From Base to Bottom of Firebox Opening floor 5 3 4 Max Base andwallsurroundstopreventairintrusion Usenoncombustiblecaulking material only to seal the black metal facing to the surround material on the f...

Страница 16: ... this Page APPROVED ACCESSORIES AND COMPONENTS Forced Air Blower Kits Cat No ModelNo Description 80L84 FBK 100 Blower Standard single speed 80L85 FBK 200 Blower Variable Speed w wall mounted switch Outside Air Gate Duct Kit Cat No Model No Description H3991 OAK UVFRC Outside Air Gate Duct Kit ref Form 750206M Touch Up Paint Kit Cat No ModelNo Description F1882 SCTPSAB Black touch up paint powder c...

Страница 17: ...he bottom left front corner of the appliance If you encounter any problems or have any questions concerning the installation of a Vent Free heater in this system please contact your dis tributorordealerorvisitourwebsiteatIHP us comforreferralinformation No Description Orion32ZP2 Cat F3313 Orion36ZP2 Cat F3314 Orion42ZP2 Cat F3315 Orion32ZB6 Cat F3316 Orion36ZB6 Cat F3317 Orion42ZB6 Cat F3318 Cat N...

Страница 18: ...________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Страница 19: ... fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use The Product is designed to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive te...

Страница 20: ...arth Products IHP reserves the right to make changes at any time without notice in design materials specifications prices and the discontinuance of colors styles and products Consult your local distributor for fireplace code information 1769 East Lawrence Street Russellville AL 35654 P900850 00 ...

Отзывы: