THE WARRANTY

Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Astria

®

 brand wood burning fireplace ("Product") to be free from defects in materials and work-

manship at the time of manufacture. The Product body, firebox and ceramic glass carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty 

against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year 

Limited Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or 

replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also 

pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS AND 

LIMITATIONS to this 20 Year Limited Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the 

date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.
This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The Product body and firebox carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components, paint and applied stains are 

excluded from this 20 Year Limited Warranty. The following do not carry a 20 Year Limited Warranty but are warranted as follows:

Air tubes, baffles and brick retainers

 – Repair or replacement for one year from the date of installation

Cast iron parts

 – Replacement for one year from date of installation

Electrical components

 – Repair or replacement for one year from the date of installation

Fireplace screens, refractory and side shields (metal or refractory)

 – Repair or replacement for two years from date of installation. Excludes hairline cracks.

Fuel grates

 –These parts are considered consumable accessories and therefore are not warranted, with the exception of defects in material or workmanship which 

are covered for 90 days from the date of installation

Gaskets

 – Replacement for one year from date of installation

Gold & nickel plating

 – Replacement for two years from date of installation. Excludes tarnishing

Optional glass doors

 – Repair or replacement for 90 days from the date of installation

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component.

Parts not otherwise listed carry a 90 day warranty from the date of installation.
Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance. (The Product must be subject to normal use with approved fuels listed in the Operation 

Manual provided with the product. This includes burning such fireplace fuels as wood and natural or propane gas. Fuel products with abnormal burning characteristics, 

including but not limited to fuel such as driftwood, coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the 

Product or may cause it to function improperly.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with 

the Product; (d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.
Coverage of this 20 Year Limited Warranty is conditional upon use of an adequate fuel grate on factory-built fireplaces only, when applicable.
IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction condi-

tions which may generate negative air pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for smoking conditions caused by 

inadequate chimney height, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions. Certain IHP Products are listed for use with 

Security Chimneys International, Ltd. or IHP chimney systems only. Use of chimney components other than that specified in the Product manual will void the Product warranty.
This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction which are 

not manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due 

to any malfunction or defect in equipment are not covered by this 20 Year Limited Warranty. All replacement or repair components will be shipped F.O.B. from the nearest 

stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.
In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after 

replacement or repair, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular 

use or purpose, and there is no implied condition of fitness for a particular use or purpose.
IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.
No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year 

Limited Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to  decide, in its sole discretion, upon the method of settlement.
To receive the benefits and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.
Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. 

IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without first obtaining IHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1769 East Lawrence Street; Russellville, AL 35654 or visit our website at WWW.ASTRIA.US.COM.

Содержание Monterey F0704

Страница 1: ...led when using a vent free log heater see Ac cessories page 17 FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L autorité compétente comme le service municipal du bâtiment les pompiers etc doit être contacté avant l installation afin de détermin...

Страница 2: ...n sibility for the following actions a Modification of the fireplace or any of the components manu factured by IHP unless otherwise permitted by IHP b Use of any component part not manufactured or approved by IHP in combination with an IHP fireplace system c Installation and or operation in a manner other than instructed in this manual d The burning of any other fuel not tested or approved by IHP ...

Страница 3: ...oodorwoodsthathavebeendippedintar pitch pine tar creosote etc Wood products made with synthetic binders such as plywood produce ab normally high temperatures and sputtering smoking fires When burning artificial logs please read and follow the instructions provided by the manufacturer Never burn treated construction lumber or scraps These woods burn excessively hot and may contain chemicals used to...

Страница 4: ...ire SAFETY Continued Figure 1 Dimensions WARNING Always leave glass doors fully opened or fully closed when operating fireplace WARNING Children and adults should be alerted to the hazards of high surface temperatures and to stay away to avoid burns or clothing ignition Young children should be carefully supervised when in the same room as fireplace MODEL CATALOG NO Monterey PFP2 F0704 29 1 2 750 ...

Страница 5: ...ther flam mable liquids may be stored The firebox area must be kept clear and free from these combustible materials The typical installation for this fireplace is a projected installation which allows you to extend the fireplace any distance into the room A projection may be ideal for a new addition on an existing finished wall Figure 3 Firebox Clearances Figure 2 Common Location of Fireplace MINI...

Страница 6: ...ming Firebox with Z Type Ember Protectors Figure 7 Ember Protectors Figure 8 Nailing Flanges HEARTH EXTENSIONS A hearth extension projecting a minimum of 20 in front of and a minimum of 12 beyond each side of fireplace opening is required to protect combustible floor construction in front of fireplace see Figure 9 Fabricate a hearth extension using a material which meets the following specificatio...

Страница 7: ...2 from effective opening of the firebox NFPA 211 Section Clearance from Combustible Material Mantels or any other combustible material may also come up to the side edge of the black metal face of the firebox only if the projection from the front face falls within limits shown in Figure 12 Figure 12 Mantel Clearances to Metal Face Figure 11 Mantel Clearances to Combustible Materials CHIMNEY PIPE WA...

Страница 8: ...or joists see Figure 15 To achieve desired offset you may install combinations of 12 18 36 and 48 length of double wall pipe see offset chart and Figure 16 Maximum length of pipe between supports is 6 feet of angled run A maximum of two 6 feet angled run sections per chimney system see Figure 18 SUPPORT SECTIONS The chimney support section is a 4 strap 12 length of pipe The height of a vertical ch...

Страница 9: ...required to avoid intrusion by in sulation and recommended to negotiate a joist see Figure 20a Figure 18 Typical Offset Installations Figure 21 10 Foot Rule 6 Ft 183 cm Max 6 Ft 183 cm Max 6 Ft 183 cm Max 6 Ft 183 cm Max 6 Ft 183 cm Max 6 Ft 183 cm Max Figure 19 Firestop Spacer with Living Space Above Ceiling Figure 20 Firestop Spacer with Attic Space Above Ceiling Existing Ceiling Frame Firestop ...

Страница 10: ...f drops 6 for each 12 one measure horizontally down from roof rafters 3 Use roof opening chart Figure 23 to determine correct opening length and flashing required 4 Remove shingles around opening measured Cut out this section 5 Addnextsectionsofpipeuntilendpenetratesroofline Checktosee that proper clearances are maintained Extend chimney by adding sections of double wall pipe until pipe is minimum...

Страница 11: ...n being used Figure 24 Flashing Installation Figure 25 Storm Collar CHASE INSTALLATIONS Instructions for chase installations are included with the chase style termination chosen In a multiple chase installation be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another Terminations must be separated a minimum of 24 center to center and stack...

Страница 12: ...ble material may be used for facing glass tile brick etc as long as proper clearances are adhered to and fireplace openings are not obstructed in any way see Minimum Clearance to Combustibles page 5 and Figure 28 Use only heat resistant noncombustible mortar or adhesive when securing facing material to front of fireplace When placing facing at upper edge of effective opening of fireplace provide L...

Страница 13: ...gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap and water solutiontoallconnectionsandjoints Bubblesforming show a leak Correct all leaks at once DO NOT USE AN...

Страница 14: ...OORSFULLYCLOSED IFDOORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT OF THE FIREPLACE OPENING CREATING RISKS OF BOTH FIRE AND SMOKE WARNING Discontinue use of the appliance immediately if doors are damaged and contact a qualified installer for repair Only doors certified with the appliance shall be used WARNING Do not slam or strike doors Damage can result in a hazardous condition Figure 31 Cabinet ...

Страница 15: ...ld be carefully supervised when they are in the same room as fireplace OPERATION AND MAINTENANCE GUIDELINES Continued REPLACEMENT PARTS See Page 16 Fireplace Accessories section for replacement parts Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repa...

Страница 16: ...et Door 2 sides end panel Platinum Finish J0453 DGPN36 36 Peninsula Wood burning Cabinet Door 2 sides end panel Brushed Finish DOUBLE WALL PIPE F0932 12 12DM 12 Section Double Wall Pipe Snap Lock F0933 18 12DM 18 Section Double Wall Pipe Snap Lock F0934 24 12DM 24 Section Double Wall Pipe Snap Lock F0935 36 12DM 36 Section Double Wall Pipe Snap Lock F0936 48 12DM 48 Section Double Wall Pipe Snap L...

Страница 17: ...d when installing a vent free gas log in this fireplace F1764 GA6050 Black Fireplace Hood FIRESTOP THIMBLE F0944 FST10 Firestop Thimble HIGHT TEMPERATURE TOUCH UP PAINT Not Shown J3943 Kit Touch Up paint LABEL UL127 50PK WARNING HOT Fire Risk Insulation and combustibles must not touch pipe Consult manual for clearance requirements Ensure proper connection WARNING HOT Fire Risk Insulation and combu...

Страница 18: ...mney Support F0960 RLT 12HT Round Top w Louvers F0961 AP 12HT Anchor Plate Collar Assembly Masonry Fireplaces F0951 CAK 12 Cold Air Collar Kit When ordered alone this part cannot ship via parcel delivery services IMPORTANT NOTICE A manufactured shroud which has been approved by a national testing agency for use with this fireplace may be used if installed in accordance with the instruc tions by it...

Страница 19: ...ing the proper venting system for your installation American National Standards Institute ANSI NFPA 211 Standard for Chimneys Fireplaces Vents and Solid Fuel Burning Appli ances See Draft Section A chimney or vent shall be so designed and constructed to develop a flow sufficient to completely remove all flue and vent gases to the outside atmosphere The venting system shall satisfy the draft requir...

Страница 20: ...The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of the unit for the hearth extension and the mantel and taking into consideration the location of the hot air ducts some models outside air kit and chimney Ifpossible youshouldchoosealocationwherethechimneywi...

Страница 21: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Страница 22: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Страница 23: ...or propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with th...

Страница 24: ...01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products LLC P N 126656 01 Rev D 02 2018 1769 East Lawrence Street Russellville AL 35654 ...

Отзывы: