Astria Fireplaces MAGNIFLAMEOD30NM Скачать руководство пользователя страница 29

Printed in U.S.A. © 2013  Innovative Hearth Products

P/N 900201-00, Rev. B  02/2018

Innovative Hearth Products

1769 East Lawrence Street • Russellville, AL 35654

Innovative Hearth Products

Astria

®

 Brand Gas Log Set & Outdoor Gas Fire Pit

Limited Three Year Warranty

THE WARRANTY

Innovative Hearth Products Limited Three Year Warranty ("IHP") warrants your Astria

®

 brand Gas Log Set or Outdoor Gas Fire Pit ("Product") to be free from defects in 

materials and workmanship at the time of manufacture. The logs and grate carry the Limited Three Year Warranty. After installation, if covered components manufactured 

by IHP are found to be defective in materials or workmanship during the Limited Three Year Warranty period and while the Product remains at the site of the original instal-

lation, IHP will, at its option, repair or replace the covered components. If repair or replacement is not commercially practical, IHP will, at its option, refund the purchase 

price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing 

or replacing such components. THERE ARE EXCLUSIONS AND LIMITATIONS to this Limited Three Year Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of 

product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This Limited Three Year Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be  purchased through a listed supplier of IHP and proof of purchase must be 

provided. The following do not carry the Limited Three Year Warranty but are warranted as follows:

Gas components

 – Repair or replacement for one year from the date of installation.

Remote control

 – Repair or replacement for one year from the date of installation.

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component.

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 

natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 

and could result in a fire hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 

(d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.

This Limited Three Year Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction which are 

not manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 

any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after 

replacement or repair, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular 

use or purpose, and there is no implied condition of fitness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this Limited Three Year Warranty. The duration of any implied warranty is limited to the duration of this expressed 

warranty.

No one is authorized to change this Limited Three Year Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and 

provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of 

this Limited Three Year Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this Limited Three Year Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefits and advantages described in this Limited Three Year Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP. 

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. 

IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without first obtaining IHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1769 East Lawrence Street; Russellville, AL 35654 or visit our website at WWW.ASTRIA.US.COM.

Содержание MAGNIFLAMEOD30NM

Страница 1: ...an en closed space such as a camper tent car or home DANGER FIRE OR EXPLOSION HAZARD If you smell gas Shut off gas to the appliance Extinguish any open flame If odor continues leave the area immediat...

Страница 2: ...ion consult a qualified installer service agency or the gas supplier DANGER Carbon monoxide poisoning may lead to death WARNING This product can expose you to chemi calsincludingCarbonBlack whichiskno...

Страница 3: ...nadjustablesafety gate to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces 2 Do not place propane LP supply tank s inside any structure Locate prop...

Страница 4: ...r residue within burner box or on adjacent walls and furniture 9 Do not use this appliance as a wood burning appliance Use only the logs provided with the appliance Do not burn solid fuels in this app...

Страница 5: ...s but with no overhead cover 2 Within a partial enclosure which includes an overhead cover and no more than two side walls These side walls may be parallel as in a breezeway or at right angles to each...

Страница 6: ...d accessory Even if noncombustible material is more than 12 you may need the hood accessory to deflect heat away from your mantel shelf See Figure 3 and Figures 4 and 5 Page 7 for minimum clearances I...

Страница 7: ...ANCES In addition to meeting noncombustible material clearances you must also meet required clearances between fireplace opening and mantel shelf If you do not meet the clearances listed below you wil...

Страница 8: ...sq inches WARNING You must secure this appliance to fire placefloor Ifnot appliancewillmovewhenyouadjust controls Moving appliance may cause a gas leak WARNING Ifinstallinginasunkenfireplace special c...

Страница 9: ...ocalcodes Usepipeof1 2 diameter or greater to allow proper gas volume to appliance If pipe is too small undue loss of volume will occur An equipment shutoff valve with 1 8 NPT tap is an acceptable al...

Страница 10: ...rrosive leak detection fluid to all joints Bubbles forming show a leak 4 Correct all leaks at once PRESSURE TESTING APPLIANCE GAS CONNECTIONS 1 Open equipment shutoff valve see Figure 13 2 Open main g...

Страница 11: ...ogs and set aside 3 Locate mounting screws on sides of appliance base assembly and remove screws Set screws aside for reinstallation 4 Disconnect gas line from appliance base as shown in Figure 9 Page...

Страница 12: ...and the round tube burner Slide the log in place as shown in Figures Burner Tube Grate Finger Round Tube Burner Grate Finger Right Front Log D 019 or D027 Figure 18B Installing Right Front Log Top Vie...

Страница 13: ...ly by inserting it from the left side as shown in Figure 19 You will need to twist the log slightly to get it to fit against the burners properly It will rest even with the back edge of the pan Back L...

Страница 14: ...of the log faces forward The log has a notch that fits around the burner tube on the right side The left side of the burner tube fits into the notch on the back side of this log The log is placed pro...

Страница 15: ...f this log has a round hole that fits over the round peg that is on the top of the back left log The right end of this log has a rectangular hole that fits over the rectangular peg on the top of the r...

Страница 16: ...the next step 6 Press in and turn control knob counterclockwise to the PILOT position Press in control knob for five 5 seconds see Figure 26 7 With control knob pressed in press and release igniter b...

Страница 17: ...clean Inspect these areas of appliance before each use Haveapplianceinspectedyearlybyaqualifiedservice person WARNING Failure to keep the primary air opening s oftheburner s cleanmayresultinsooting a...

Страница 18: ...logs for cleaning refer to Installing Logs and Volcanic Stone Page 12 to properly replace logs Replace log s if broken or chipped dime sized or larger MAIN BURNER Periodically inspect all burner flame...

Страница 19: ...0NM Rating Variable 29 000 40 000 Btu Hr Type Gas Natural Ignition Electronic Manifold Pressure 3 4 W C Inlet Gas Pressure in of water Max 10 5 W C Min 5 W C For purpose of input adjustment To Thermop...

Страница 20: ...gged 7 Gas regulator setting is not correct 1 Turn on gas supply or open equipment shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT posi tion 4 Continue holdi...

Страница 21: ...sses and logs curing 1 Problem will stop after a few hours of operation Appliance produces a whistling noise when burners are lit 1 Turning control knob to HI position when burners are cold 2 Air in g...

Страница 22: ...ontrol defective 1 Locate and correct all leaks see Checking Gas Connections Page 10 2 Replace control valve or gas control Gas odor during combustion 1 Foreign matter between control valve and burner...

Страница 23: ...lace Fits openings 28 to 48 wide RECEIVER AND HAND HELD REMOTE CONTROL KIT MRC REMOTE READY MODELS ONLY Cat No F1077 Model MRC For all models Allows the fireplace to be turned on and off by using a ha...

Страница 24: ...9 10 13 14 15 16 17 18 19 20 21 23 24 25 22 11 12 12 7 3 4 Cat No Model F0562 MagniFlameOD30NM F0564 MagniFlameOD30PM WARNING Failure to position the parts in accordance with these diagrams or failur...

Страница 25: ...tric 1 15 J6144 Bracket Igniter 1 16 J5198 Shutter Air NG 1 J5199 Shutter Air LP 1 17 J3604 Orifice 0 12 NG 1 J3615 Orifice 0 07 LP 1 18 J6127 Orifice Holder 90 Degrees 1 19 J4733 Nut and Sleeve Brass...

Страница 26: ...er assembly The next two numbers indicate the set size 2 6 3 9 1 7 8 5 4 KEY NO CAT NO Log Id CAT NO Log Id DESCRIPTION QTY 1 J6516 D 019 J6527 D 027 Log Front Right 1 2 J6517 D 018 J6528 D 026 Log Ba...

Страница 27: ...ted under Replacement Parts on Page 28 of this manual KEY NO CAT NO Log Id CAT NO Log Id DESCRIPTION QTY 1 J8253 D 019 J8259 D 027 Log Front Right 1 2 J8254 D 018 J8260 D 026 Log Back Left 1 3 J8255 D...

Страница 28: ...have any questions concerning the installation or application of this appliance please contact your dealer IHP 1769 East Lawrence Street Russellville AL 35654 Visit us at Astria us com SERVICE HINTS...

Страница 29: ...mage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions prov...

Страница 30: ...serial number Date appliance was Installed Type of gas appliance uses Dealer name Innovative Hearth Products IHP reserves the right to make changes at any time without notice in design materials speci...

Отзывы: