background image

4 (102)

2

(51)

4

(102)

6

(152)

8

(203)

10

(254)

12

(305)

6 (152)

10 (254)

14 (356)

12 (305)

8 (203)

Printed in U.S.A. © 2016 Innovative Hearth Products

P/N  900661-03  REV. NC  05/2016 

Page 2 of 2

Specifi cations and clearances are subject to change without notice.  
Refer to Installation Manual before installation of these appliances for 
updated dimensions and instructions.

10-1/2”

(267mm)

7"

(178)

5-1/8”

(130 mm)

12-1/8”

(308 mm)

3"

(77 mm)

1"

(26 mm)

Adaptor SV4.5RCH

Square Horizontal Termination (SV4.5HT-2)

 

6 to 48” Vent Section, 
Telescopic vent section, 
Elbow or Appliance 
Collar

See 

Page 1

  for Min. 

Distance to Base of Appliance.

NOTE: Center line of 
Vent Piping is NOT 
the Same as the 
Center line of the 
Framed Opening.

To help minimize water infi ltration it is recom-
mended that the Firestop/Spacer (SV4.5HF) be 
installed on the exterior side of the wall.

* Ceiling Firestop/ 
Spacer (SV4.5VF)

Vertical Termination 
Cap SV4.5CGV-1 
(rated for high winds 
and freezing conditions)

Ceiling Framing

10-1/2”

(267 mm)

10-1/2”

(267 mm)

Typical 
Installation

Venting

Clear

anc

es

Shelf Height

Listing 

Pr

oduc

t Info

Minimum Clearances 

Inches (millimeters)

Back & Sides

1/2 (13)

0 (0) from Spacers or 

Dimples

Top Spacers

0 (0)

Floor

0 (0)

From Bottom of 

Unit To Ceiling

64 (1626)

Vent

3 (77) Top* / 1 (26) 

Sides & Bottom

Service Clearances - Feet (meters)

Front, Back & 

Sides

3 feet (0.9 meters)

LIBRA 40CL

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Report No. 14-171

Shelf Above Fireplace

With Rear Venting

Do not insulate the

space between the

appliance and the

area above it.

Shelf Height

(

see table)

Shelf Above Fireplace

With Top Venting

Do not insulate the

space between the

appliance and the

area above it.

Shelf Height

(

see table)

Model

Combustible Shelf Height - Inches (millimeters)

Top Vent - with One 90º Elbow

Rear Vent - Straight Out the Back

Secure Vent

®

Secure Flex

®

Secure Vent

Secure Flex

LIBRA 40CL

53-7/8 (1368)

55-5/8 (1413)

41-1/8 (1045)

41-1/8 (1045)

*NOTE: 3” (77 mm) above any horizontal/ 
inclined vent component. 

inches (millimeters)

Top of 
Appliance

Mantel Depth

Front or Rear Face 

of Appliance

PFS

®

US

C

Top View of

Fireplace

Combustible Walls

A Combustible Wall 
may extend to any 
length on one side only. 
If installed as shown, 
opposite side is limited 
to 6" 

(153 mm)

.

6" (153 mm)

These appliances comply with National Safety 
Standards and are tested and listed by PFS to 
ANSI Z21.88 (in Canada, CSA-2.33), and CAN/
CGA-2.17-M91, latest editions, in both USA 
and Canada, as vented gas fi replace heaters.

Product Reference Information

Cat. No.

Model

Shipping 

Weight

  Shipping

Volume

F1591

LIBRA 40CLDMN

299 lbs.

 42.0 cu.ft.

F1592

LIBRA 40CLDMP

299 lbs.

  42.0 cu.ft.

F1593

LIBRA 40CLDEN

299 lbs.

  42.0 cu.ft.

Uses 4.5” / 7.5” Secure Vent

®

 Rigid and 

Secure Flex

®

 Direct-Vent Components

f i r e - p a r t s . c o m

Отзывы: