4 (102)
2
(51)
4
(102)
6
(152)
8
(203)
10
(254)
12
(305)
6 (152)
10 (254)
14 (356)
12 (305)
8 (203)
Printed in U.S.A. © 2016 Innovative Hearth Products
P/N 900661-03 REV. NC 05/2016
Page 2 of 2
Specifi cations and clearances are subject to change without notice.
Refer to Installation Manual before installation of these appliances for
updated dimensions and instructions.
10-1/2”
(267mm)
7"
(178)
5-1/8”
(130 mm)
12-1/8”
(308 mm)
3"
(77 mm)
1"
(26 mm)
Adaptor SV4.5RCH
Square Horizontal Termination (SV4.5HT-2)
6 to 48” Vent Section,
Telescopic vent section,
Elbow or Appliance
Collar
See
Page 1
for Min.
Distance to Base of Appliance.
NOTE: Center line of
Vent Piping is NOT
the Same as the
Center line of the
Framed Opening.
To help minimize water infi ltration it is recom-
mended that the Firestop/Spacer (SV4.5HF) be
installed on the exterior side of the wall.
* Ceiling Firestop/
Spacer (SV4.5VF)
Vertical Termination
Cap SV4.5CGV-1
(rated for high winds
and freezing conditions)
Ceiling Framing
10-1/2”
(267 mm)
10-1/2”
(267 mm)
Typical
Installation
Venting
Clear
anc
es
Shelf Height
Listing
Pr
oduc
t Info
Minimum Clearances
Inches (millimeters)
Back & Sides
1/2 (13)
0 (0) from Spacers or
Dimples
Top Spacers
0 (0)
Floor
0 (0)
From Bottom of
Unit To Ceiling
64 (1626)
Vent
3 (77) Top* / 1 (26)
Sides & Bottom
Service Clearances - Feet (meters)
Front, Back &
Sides
3 feet (0.9 meters)
LIBRA 40CL
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Report No. 14-171
Shelf Above Fireplace
With Rear Venting
Do not insulate the
space between the
appliance and the
area above it.
Shelf Height
(
see table)
Shelf Above Fireplace
With Top Venting
Do not insulate the
space between the
appliance and the
area above it.
Shelf Height
(
see table)
Model
Combustible Shelf Height - Inches (millimeters)
Top Vent - with One 90º Elbow
Rear Vent - Straight Out the Back
Secure Vent
®
Secure Flex
®
Secure Vent
Secure Flex
LIBRA 40CL
53-7/8 (1368)
55-5/8 (1413)
41-1/8 (1045)
41-1/8 (1045)
*NOTE: 3” (77 mm) above any horizontal/
inclined vent component.
inches (millimeters)
Top of
Appliance
Mantel Depth
Front or Rear Face
of Appliance
PFS
®
US
C
Top View of
Fireplace
Combustible Walls
A Combustible Wall
may extend to any
length on one side only.
If installed as shown,
opposite side is limited
to 6"
(153 mm)
.
6" (153 mm)
These appliances comply with National Safety
Standards and are tested and listed by PFS to
ANSI Z21.88 (in Canada, CSA-2.33), and CAN/
CGA-2.17-M91, latest editions, in both USA
and Canada, as vented gas fi replace heaters.
Product Reference Information
Cat. No.
Model
Shipping
Weight
Shipping
Volume
F1591
LIBRA 40CLDMN
299 lbs.
42.0 cu.ft.
F1592
LIBRA 40CLDMP
299 lbs.
42.0 cu.ft.
F1593
LIBRA 40CLDEN
299 lbs.
42.0 cu.ft.
Uses 4.5” / 7.5” Secure Vent
®
Rigid and
Secure Flex
®
Direct-Vent Components
f i r e - p a r t s . c o m