Astria Fireplaces Blackstone Series Скачать руководство пользователя страница 22

Astria.us.com

901046-00NC

22

APPENDIX A 

Continued

Smoking –  Causes And Troubleshooting

To reduce the likelihood of smoking when opening the door, open 

the combustion air control or damper before opening the door.  

Your appliance has been designed and tested to provide smoke free 

operation. Occasionally, there may be a small amount of smoking 

upon lighting the fire, until the chimney heats up but this should not 

continue.  If the appliance continues to smoke it is probably for one 

of the following reasons:

A. Negative pressure in the house -

  As the fire burns, air goes up the chimney. This air must be 

replaced through leakage into the house or through the outside 

air duct.  When operating the appliance, open a nearby window 

temporarily to check if there is adequate replacement air supply.

B. Blowers operating (e.g.: range hood) - 

These blowers draw air 

out of the house and may actually cause a negative pressure in 

the house.  Turn off all blowers and open a nearby window to 

determine if this is the cause of the problem.

C. Wet wood -

 Wet or tarred wood will smoulder and smoke instead 

of burning properly. Your dealer can help you determine if you 

have properly seasoned wood for burning.

D. Dirty or blocked chimney -

 Check to make sure the chimney is 

clear and clean. If dirty call a certified chimney sweep or use a 

properly sized chimney brush to clean.

E. Chimney not long enough -

 The minimum chimney height is 

twelve (12) feet (3.7 m) not including the appliance height. The 

chimney must extend at least three (3) feet (915 mm) above 

its point of contact with the roof and at least two (2) feet (610 

mm) higher than any roof or wall within ten (10) feet (3 m) of 

it.  When installed with offsets, the minimum chimney height 

is fifteen (15) feet.  Additional height will increase draft and will 

decrease the tendency to smoke.

F.  Poor chimney draft -

 With no fire, there should be sufficient draft 

to exhaust cigarette smoke introduced under the baffle or flue baffle.  

Chimneys installed against an outside wall without protection may 

generate back draft problems which will cause start-up problems.  

To prevent this, open a nearby window, roll up a piece of paper 

and light it.  Then, hold it in the upper part of the firebox to warm 

up the chimney.  Wait until the draft is sufficient, then start the fire.

G. Blower for forced air kit operating (some models)  -

 Make 

sure that the blower is in the “off” position when you open the 

appliance door for reloading.

Locating The Appliance

The best location to install your appliance is determined by consid-

ering the location of windows, doors, and the traffic flow in the room 

where the appliance is located, allowing space in front of the unit for 

the hearth extension and the mantel, and taking into consideration 

the location of the hot air ducts (some models), outside air kit and 

chimney. 

If possible, you should choose a location where the chimney will pass 

through the house without cutting floor or roof joists.
When selecting the location, the chimney outlet position and the 

direction of the wind are important factor affecting the chimney per-

formance. To allow a maximum draft and to reduce wind turbulence, 

the chimney must:

•  Penetrate the highest part of the roof.

•  Be installed as far as possible of roof offsets, trees or any other 

obstructions that may cause wind turbulence and back drafts in 

the chimney.

•  The least amount of offsets (elbows) possible. 

NOTE:

 A maximum 

of 2 offsets is allowed.

4' 

4' 

8' 

Standard 

Cord of

Wood

8 Ft. 

(2.4M)

4 Ft. 

(1.2M)

4 Ft. (1.2M)

Marginal Location

Wind Direction

Location

Not

Recommended

Outside Air 

Intake

Facing the Wind

Location

Not 

Recommended

Location Recommended

Tree

Figure 1

Figure 2

Prohibited Fuels

These appliances are designed to burn natural well-seasoned wood. 

The wood fuel should be air dried seasoned hardwoods, as compared 

to softwoods or to green or freshly cut hardwoods. Burning artificial 

logs, in some model appliances is allowed (see Installation and Op-

eration manual); please read and follow the instructions provided by 

the manufacturer. DO NOT BURN:

NOTE: The use of a firewood moisture meter is recommended 

to ensure the firewood contains less than 20% moisture.

Seasoning Guide

Softwoods  -  6 months to 18 months

Hardwoods  -  12 months to 24 months
Logs that are 5” diameter across or larger should be split in half, 

three pieces if over 8 inches, and four pieces when over a foot 

across. If a tree has been dead for 2  -  4 years it still needs to be 

cut, split, and seasoned for 6 to 24 months depending on the wood.

• Garbage;

•  Lawn clippings or yard waste;

•  Materials containing rubber, 

including tires;

•  Materials containing plastic;

•  Waste petroleum products, 

paints or paint thinners, or 

asphalt products;

•  Materials containing asbestos;

•  Construction or demolition 

debris;

•  Railroad ties or pres-

sure-treated wood; woods that 

have been dipped in tar, pitch, 

pine tar, creosote, etc.

• Manure or animal remains;

• Salt water driftwood or 

other previously salt water 

saturated materials;

• Unseasoned wood;

• Christmas tree branches;

• Paper products, colored 

paper, cardboard, plywood, 

or particleboard; 

• Gasoline;

• Naphtha;

• Engine Oil; 

• Flammable Liquids; 

• Solvents;

• Grease; or

• Charcoal or Coal

Содержание Blackstone Series

Страница 1: ...iction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L autorit comp tente comme le servi...

Страница 2: ...red or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Consult the local building...

Страница 3: ...gnificanthazard IMPORTANT See appendix A page 21 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CAR...

Страница 4: ...RD NOT LESS THAN 12 305 mm TO PERPENDICULAR SIDEWALL 0 0 MM TO BOTTOM 12 305 mm EACH SIDE GAS LINE KNOCK OUT GAS LINE KNOCK OUT RIGHT SIDE LEFT SIDE AIR KIT KNOCK OUT 8 1 4 210 mm 8 1 4 210 mm 25 3 8...

Страница 5: ...langes touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be placed between hearth extension not...

Страница 6: ...ening of fireplace NFPA 211 Section Clearance from Combustible Material Mantels or any other combustible material may come up to side edge of black metal face of fireplace if projection from front fac...

Страница 7: ...ugh a sidewall AK4 See Figure 7 for instruction of operating air kit CAUTION Combustion air inlet ducts shall not terminate in attic space The maximum height for the air vent can not exceed 3 feet bel...

Страница 8: ...20 feet must be supported USING ELBOW OFFSETS 30E 8DM 1 To achieve desired offset you may install combinations of 12 18 24 36 and 48 length of double wall pipe see offset chart page 9 and Figure 9 pag...

Страница 9: ...turn Elbow Return Elbow Return Elbow Return Elbow Offset Elbow Offset Elbow Offset Elbow Offset Elbow Offset Elbow 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m Ceiling...

Страница 10: ...oof Pitchisthedistancetheroofdrops overagivenspan usually12 A6 12pitchmeansthattheroofdrops 6 for each 12 measure horizontally down from roof rafters 3 Use roof opening chart Figure 14 page 11 to dete...

Страница 11: ...ireplace system must be terminated with listed round top or chase terminations In any case refer to installation instructions supplied with termination Terminations approved for this fireplace are RT...

Страница 12: ...d is to be installed contact manufacturer for specifications Figure 18 Multiple Chase Installation 10 3 05 m 10 3 05 m 2 0 61 m Min 2 0 61 m Min 3 0 92 m Min 3 0 92 m Min Level of Flue Gas Outlet Figu...

Страница 13: ...desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap and water solution to all connections and joints...

Страница 14: ...ce with glass doors has a limited amount of air for combustion Excessive heat within fireplace can result if too large a fire is built or if combustion air gate is not completely open The following ti...

Страница 15: ...in accordance with the instructions by its manufacturer A locally fabricated shroud may be used with IHP Shroud Leg Spacer Kit SLK in accor dance with instructions provided with the shroud NOTICE The...

Страница 16: ...1046 00NC 16 11 27 23 23 22 24 10 14 25 4 17 3 2 1 18 5 20 28 12 7 15 9 16 13 8 26 6 19 21 PARTS WOOD BURNING FIREPLACE MODELS Blackstone42RWS Blackstone42LWS MODEL CAT NO Blackstone42RWS F2539 Blacks...

Страница 17: ...9 Wrapper Bottom 1 10 Front Face Weldment Smooth 1 Front Face Weldment Louvered 1 11 See Page 18 Left Side Brick Liner 1 12 See Page 18 Rear Brick Liner 1 13 See Page 18 Right Side Brick Liner 1 14 S...

Страница 18: ...n any of these parts Never use substitute materials not ap proved by IHP Use of non approved parts can result in poor performance and safety hazards 1 2 4 3 6 5 REFRACTORY STAIN KITS Use the refractor...

Страница 19: ...Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock 30 OFFSET AND RETURN F0900 30E 8DM 30 D...

Страница 20: ...AND SLIP SECTION F0921 ETL 8DM Square Top with Slip Section F0893 ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TER...

Страница 21: ...ns inadequate chimney heights adversewindconditionsand orunusualenvironmental factors or conditions beyond our control take into account all variables within the installation and install the appliance...

Страница 22: ...he best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of the un...

Страница 23: ...r propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperature...

Страница 24: ...0 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your loc...