![Astrapool 71245 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/astrapool/71245/71245_user-and-service-manual_2990734013.webp)
- 13 -
7. Maintenance
(1) You should check the water supply system regularly to avoid the air entering the system and occurrence of low
water flow, because it would reduce the performance and reliability of HP unit.
(2) Clean your pools and filtration system regularly to avoid the damage of the unit as a result of the dirty of
clogged filter.
(3) You should discharge the water from bottom of water pump if HP unit will stop running for a long time
(especially during the winter season).
(4) In another way, you should check the unit is water fully before the unit start to run again.
(5) After the unit is conditioned for the winter season, it is recommended to cover the heat pump with special
winter cover.
(6) When the unit is running, there is all the time a little water discharge under the unit.
(7) The pipe must be vacuumed before filling R32 gas from the shut off valve inside machine.
(8) Action of filling gas must be conducted by professional with R32 operating license.