Astralpool RX 280 Скачать руководство пользователя страница 4

Inst.246 RX Series & E Series Sand Filter V01.15 

VALVE OPERATION 

 

The operation and the positions of valve settings are as follows: 

 

Valve Settings 

Direction of flow through Valve 

Filter (also during vacuuming) 

From pump down through valve, through sand bed, 
up through stand pipe to valve and back through 
pool return. 

Back Wash 

From pump, through valve, down through stand 
pipe, up through sand bed, and through valve to 
waste. 

Rinse 

Flow from pump, through valve, down through sand 
bed, up through stand pipe, through valve to waste.  
(Position also used for initial start-up and leveling 
sand bed after Back-wash) 

Waste 

From pump, through valve to waste.  Also position 
for lowering water level or assist in draining pool. 

Closed 

From pump to valve without further circulation.  
Prevents any flow to filter and pool. 

Recirculate 

From pump through valve to pool.  This position bi-
passes the filter and is used for circulation of pool 
water only. 

 
 
 

NOTE: Always “STOP” pump when changing selector valve position. 

INITIAL START - UP 

1.  Make sure the correct amount of media is in the filter tank. 
2.  Prime pump. 
3.  Set valve handle in BACK WASH position. 
4.  Start pump and operate in BACK WASH cycle for three (3) minutes.  This will purge the filter of excess 

fines in the media.   

5.  Turn pump OFF and set valve handle to RINSE.  Start pump and run for one (1) minute. 
6.  Stop pump and set valve handle to FILTER.  Restart pump.  System is now operating on a normal FILTER 

cycle. 

7.  Adjust the valves in the skimmer and main drain lines (if provided) to achieve balanced flow rates. 
8.  When a pool is filled initially, the filter may have to be BACK WASHED once a day until the water becomes 

sparkling clear.  From that point on, BACK WASH when pressure gauge indicates 30 to 40 kPa higher 
than at starting pressure. 

 

OPERATIONAL & INSTALLATION TIPS 

1.  Always turn pump 

“OFF”

 before changing valve positions. 

2.  Never run pump dry as it depends on water for lubrication. 
3.  Always maintain minimum water level to 

½

 way up the skimmer mouth. 

4.  Clean pump strainer regularly. 
5.  Maintain a proper chemical balance in the pool. 
6.  Maximum operating pressure is 250kPa on RX Series and 140kPa on E-Series. 
7.  Ensure pressure gauge on valve is positioned so that rain water cannot collect on glass face. 
8.  Back wash filter regularly for 3-5 minutes each time to ensure sand is completely cleaned. 

 

 

 

Содержание RX 280

Страница 1: ...08 9350 2600 Sydney Nth 02 9853 2100 Sydney Sth 02 8778 9500 Townsville 07 4796 0100 Brisbane 07 3308 5400 Adelaide 08 8152 7600 www astralpool com au sales astralpool com au Bolero ND Cleaner INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS RX Series E Series Sand Filters ...

Страница 2: ...0ltrs 192 000ltrs 125 kg 175 kg 200 kg Dimensions With Valve Installed Model Height Width Shipping Weight RX 280 RX 360 RX 400 105 cm 106 cm 114 cm 61 cm 70 cm 76 cm 22 kg 32 kg 38 kg Model No Tank Diameter Filter Area Port Size 6 Hr Turnover 8 Hr Turnover Media Req d Eco 550 Eco 650 Eco 750 550 mm 650 mm 750 mm 0 20 Sq M 0 33 Sq M 0 42 Sq M 40 mm 40 mm 50 mm 65 000 ltrs 92 000 ltrs 120 000 ltrs 8...

Страница 3: ...ateral hub and stand pipe are intact inside the tank 3 Fill tank half full with water 4 Place the disposable loading disc into the upper tank opening and the plastic cover over stand pipe to stabilise the filter and stand pipe It is important that the stand pipe remains centered through the media loading procedure to ensure alignment with valve assembly opening 5 Proceed to load correct volume of ...

Страница 4: ...ter tank 2 Prime pump 3 Set valve handle in BACK WASH position 4 Start pump and operate in BACK WASH cycle for three 3 minutes This will purge the filter of excess fines in the media 5 Turn pump OFF and set valve handle to RINSE Start pump and run for one 1 minute 6 Stop pump and set valve handle to FILTER Restart pump System is now operating on a normal FILTER cycle 7 Adjust the valves in the ski...

Страница 5: ...ck inlet outlet o rings for leaks Isolate Pump turn power off clean and grease O rings or replace if necessary Annually Compare operating pressure of backwashed filter to initial pressure when new If using Zeolite or M3 regenerate filter media This is important in commercial applications as it aids in the removal of ammonias If pressure is more than 30 40 kPa different from new filter a media chan...

Страница 6: ... years 80 covered 20 payable 5 6 years 60 covered 40 payable 7 8 years 40 covered 60 payable 9 10 years 20 covered 80 payable If a defect appears in the Product before the end of the warranty period and AstralPool finds the Product to be defective in materials or workmanship AstralPool will in its sole discretion either a replace or repair the Product or the defective part of the Product free of c...

Страница 7: ...ny instructions by AstralPool e the Product has been subject to accident negligence alteration abuse or misuse The warranty does not extend to a normal wear and tear b weather and other environmental conditions including but not limited to storm flood and or heat wave damage or c service and maintenance items Examples of exclusions include but are not limited to sand used within the filter vessel ...

Страница 8: ...Inst 246 RX Series E Series Sand Filter V01 15 8 ...