Technical datasheet                         Revision date 26 May. 2015   

               

Troubleshooting

The controller is in bootloader mode. This is a special ‘startup mode’ 

which is run before the main firmware loads.

-Try re-writing the firmware with the latest hardware manager

-Try formatting or replacing the SD card

There is no showfile detected on the SD memory card.

-Try formatting the SD card in the computer

-Try re-writing the show file

-Try replacing the SD memory card

There is no SD card detected.

-Check the SD card is properly connected

-Try formatting the SD card in the computer

-Try re-writing the show file

-Try replacing the SD memory card

-Be sure that the latest software version is installed

-Connect by USB and open the Hardware Manager (found in the software 

directory). If it’s detected here, try to update the firmware

-Check the DMX + - and GND are connected correctly

-Check that the driver or lighting fixture is in DMX mode

-Be sure that the DMX address has been set correctly

-Check there are no more than 32 devices in the chain

-Check that the red DMX LED is flickering. There’s one by each XLR

-Connect with the computer and open Hardware Manager (found in the 

software directory). Open the DMX Input/Output tab and move the faders. 

If your fixtures respond here, it is possibly a problem with the show file

‘888’ is showing on the display

‘OFF’ is showing on the display

‘OFF’ is flashing on the display

The controller is not detected by the 

computer

The lights are not responding