background image

6

HALO

®

 HUB

   

installation manual

3.3 

Other Connections

The Halo Hub can control up to 4 valves (Valve 

1 … Valve 4) and has two temperature sensor 

connectors (water and roof). (This is in addition to the 

temperature sensor connector on a connected Halo 

Chlor.)

It can also control an AstralPool Viron Heatpump 

through the RJ45 connector, or it can control a heater 

via a voltage free heater relay (heater connector).

In addition to this, there is provision to accept 2 

low voltage inputs and control a low voltage relay 

(automation connector).

The use of the Halo Hub connections varies 

depending on the type of equipment connected. If 

your setup doesn’t require a temperature sensor (e.g. 

garden lights), then these connections are ignored.

The following table shows typical uses for the two 

temperature sensors on the Halo Hub.

NOTE:   The Halo Hub does not support the use of the filter 

pump for solar control.

Application

Purpose

Temp Sensor 1

Temp Sensor 2

Solar control

Separate solar 

pump used for 

solar

Water 

temperature

Roof 

temperature

Heater control 

(through GPO)

Main filter 

pump used for 

heater

N/A - use Halo 

Chlor water 

temperature 

sensor

N/A

Heater control 

(through GPO)

Separate pump 

used for heater

Water 

temperature

N/A

Heater control 

through the 

“Heater” 

connector, see 

Appendix 1

Main filter 

pump used for 

heater

N/A - Use Halo Chlor water 

temperature sensor

Heater control 

through the 

“Heater” 

connector

Separate pump 

used for heater

Connect thermistor into “Heater 

Connector”, see Appendix 1

Section 4.  Pairing and Configuring a 

Halo Hub

Setting up Halo equipment is a two-part process. 

Firstly pair all of the devices and then configure the 

equipment that will be connected.

NOTE:   Icons in the chlorinator app (bottom ribbon of 

the app screen and top ribbon on the chlorinator 

screen) may vary depending on what equipment 

is installed.

4.1 

Pairing to the Halo Chlor

To pair a Halo Hub to a Halo Chlor:
1.  Press the “settings” icon 

 (in the lower left 

corner) on the “HOME” page on the chlorinator.

2.  Press the “INSTALL” icon in the top ribbon of the 

“Settings” page of the chlorinator.

3.  Press “Add Remove” in the “Equipment 

Configuration” area on the install page (lower left 

corner).

The list of “Connected Devices” shows devices that can 

be connected to the Halo Chlor. These are shown with 

the symbol to the right of the device name. In this case, 

press the symbol on the Halo Hub icon.

Содержание HALO HUB

Страница 1: ...warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Improper installation and or ope...

Страница 2: ...R For full warranty terms and conditions and to register your warranty visit www astralpool com au warranty and complete your details Or scan the QR code to go directly to the registration page Record...

Страница 3: ...tions 6 Section 4 Pairing and Configuring a Halo Hub 6 4 1 Pairing to the Halo Chlor 6 4 2 Configuration and Setup 8 4 3 Unpairing from a Halo Chlor 9 Section 5 Control using the Halo Chlor 9 5 1 Manu...

Страница 4: ...supply cord is damaged it must only be replaced by AstralPool its service agent or a similarly qualified person in order to avoid a hazard WARNING The Halo Hub has an IP23 rating meaning it is suitab...

Страница 5: ...the mounting bracket through the slots Ensure the hub drops down into place Slide to the right to lock in position 3 2 Power Connections Halo Hubs are provided with a 2 8Mtr power cable for connection...

Страница 6: ...heater N A use Halo Chlor water temperature sensor N A Heater control through GPO Separate pump used for heater Water temperature N A Heater control through the Heater connector see Appendix 1 Main f...

Страница 7: ...ss Edit 5 On the next screen enable or disable each GPO outlet 1 and outlet 2 and define which equipment should be plugged into each outlet NOTE Solar pumps must use outlet 1 If a heater is being cont...

Страница 8: ...t brand of lights are they do you want to use timers to control them The General Purpose Outlets GPO s can be named using this screen If you are configuring a heater and you wish to use a separate hea...

Страница 9: ...lor 5 1 Manual Control All of the functions of the Halo Hub can be controlled using the icons in the top ribbon of the Halo Chlor display Icons will only appear in the top ribbon if appropriate device...

Страница 10: ...Heater connector is used to control heaters that can t be controlled using the RJ12 RS485 on the Halo Chlor or the RJ45 connector on the Halo Hub The heater connector consists of an input for an Astr...

Страница 11: ...me automation system to dim the outside lights etc The relay can also be used as a general output to drive other equipment rather than being linked to a favourite When used in this mode the relay can...

Страница 12: ...his document is subject to change without notice 2021 Fluidra S A All rights reserved This document is subject to change without notice Fluidra Group Australia Pty Ltd 219 Woodpark Road Smithfield NSW...

Отзывы: