INST 193 SX Series Spa Blower Vol 07-20
4
HURLCON SX SERIES BLOWER
Gooseneck
The blower should be installed in a dry location as close as possible to the spa but should not be installed within 3 meters to
comply with electrical standards. To prevent damage to the blower and electric shock the blower must be installed at least
700mm above the highest water level in the spa (see fig 2).
If the blower is to be installed below the water lever or further than 5 meters from the spa a loop must be installed at least
700mm above the highest water level (see fig 1). This loop should be installed within two meters of the spa.
FAILURE TO COMPLY WILL VOID WARRANTY.
Gas Appliances
The blower must NOT be installed within 1.5 meters of any gas appliance flue. It must NOT be installed in the same room
as a gas appliance unless, it is sealed from the plant room and draws its own fresh air supplied.
Spa Manifold
Spa Manifold ring should have sufficient holes to total 800 square mm. Insufficient air holes in the spa will cause excessive
pressure on the blower and may cause the blower to overheat and reduce the life of the motor.
As a guide the following table should be consulted:
Air Hole Size
Number of Holes
3mm
4mm
5mm
6mm
110
64
45
30
Failure to comply with minimum area of holes will void warranty
.
Specifications
Specifications
1200 Watt
Fan
Speed
R.P.M.
Input
Power
Current
Airflow
Single Stage
Single Speed
21000
240 VAC
1250 WATT
5.2A
2500 LPM