Fountain units
Installation, operation and maintenance manual; Fire Jet
19
[en]
collaborate
with
engineering
and
authorized
installers
of
compressed air and flammable liquids.
WARNING
:
Risk of damage to the unit and losing its warranty.
In order
for the safe and proper operation of the unit, the following
components are required (not included with the device):
1)
A compressed air unit for discharging the isopropanol.
2)
An isopropanol storage tank PN16 minimum, sized in order to
contain enough isopropanol for the fountain show needs.
3)
A non-return valve placed between the air compressor and the
isopropanol tank.
4)
A manifold on the isopropanol tank exit if there is more than one
device working simultaneously.
5)
Conduits for the compressed air and the isopropanol suitable for
working under water and for the working pressure, minimum
PN16. Also pipes must be inert in contact with isopropanol.
6)
Isopropanol pipe must be water-tight. Before the equipment
commissioning, carry out pipe water-tightness testing.
Connect tank’s isopropanol outlet to the conduit at the bottom (
④
④
④
④
,
¼” Whitworth male thread).
It is highly recommended installation of isopropanol cutting valve
before device inlet in order to do maintenance tasks.
Maximum device working pressure is 10Kg/cm
2
.
2.2.2
2.2.2
2.2.2
2.2.2
Electrical
WARNING
:
Risk of damage to the unit and losing its warranty.
Check
that all IP68 connectors are properly sealed and that they prevent
water getting through. Electrical components may become
damaged by flooding and the unit could lose its warranty.
WARNING
:
Risk of damage to the unit and losing its warranty.
Connect
a fuse on the current transformer positive and on the electrovalve
(230VAC) in order to protect the device from overcurrents.
-
5A fuse on current transformer positive (grey wire).
-
2A fuse on electrovalve positive (brown wire).