OPTIMA / MAYA SERIES · HEAT PUMP AIR/WATER
© FLUIDRA 2019 ALL RIGHTS RESERVED. PROPRIETARY DOCUMENT.
Pag: 47
ENGLISH
TABLE 2: TECHNICAL DATA [MAYA REVERSIBLE]
TABLE 3: MAXIMAL ELECTRICAL DATA [OPTIMA CHILLER]
CODES
VOLTAGE
WIRE
MINIMUN
SECTION
POWER
SUPPLY
COMPRESSOR
FAN
TOTAL
OPTIMA CHILLER
[V]
[mm2]
[A]
[A]
[A]
7 kW
230
4
I+N+PE
19,3
1,7
20,7
15 kW
6
23,4
0,9
24,3
15 kW
400
2,5
III+N+PE
7,5
0,9
8,4
TABLE 4: MAXIMAL ELECTRICAL DATA [MAYA REVERSIBLE]
CODES
VOLTAGE
WIRE
MINIMUN
SECTION
POWER
SUPPLY
COMPRESSOR
FAN
TOTAL
MAYA REVERSIBLE
[V]
[mm2]
[A]
[A]
[A]
15 kW
400
2,5
III+N+PE
7,5
2,4
9,9
25 kW
4
12,3
3,51
15,81
MAYA REVERSIBLE
15 KW
25 KW
CODES
32505
32506
POWER SUPPLY
400 V / 50 Hz / III+N
CONDENSER
TITANIUM
COMPRESSOR
SCROLL
FANS
UNITS
Uds.
1
1
TYPE
CENTRIFUGAL
FLOW
m
3
/h
2500
6000
REFRIGERANT GAS R-407-C
KG
2,5
6
WATER FLOW
m
3
/h
7
8
CONNECTION DIAMETER
mm
50
50
Air = 5 °C
Water = 24 °C
70% Hr
INLET POWER
kW
3,00
4,74
OUTLET POWER
kW
13,14
20,24
COP
4,37
4,27
Air = 15 °C
Water = 24 °C
70% Hr
INLET POWER
kW
3,59
5,73
OUTLET POWER
kW
16,28
24,83
COP
4,53
4,33
Air = 24 °C
Water = 24 °C
70% Hr
INLET POWER
kW
3,94
6,32
OUTLET POWER
kW
19,82
29,99
COP
5,03
4,74
SOUND
PRESSURE
dbA (d*)
70
70
dbA (5 m)
65
65
GROSS WEIGHT
kg
143
194