10. Troubleshooting
• If you notice something amiss while operating the unit, please refer to the following:
Stage
Issues, symptoms
Additional info
Likely Cause
Solution
Preparation
No power
No reaction at all
Has the power cord become
unplugged from the wall out
-
let?
Check the power cord.
It is possible that an internal
fuse has blown.
Replace the defective fuse
with a new one.
Nothing shows on the
display.
--
There is an internal problem
with the unit.
Notify the Company, then
return the unit for servicing.
Operation is slow.
--
It is normal for the unit to
require up to five seconds to
start.
--
The unit moved by itself
The Arm moved.
When the arm is out of posi
-
tion, it will return automat
-
ically to the start position.
This is not an abnormality.
Do not touch the unit until it
returns to the Standby mode.
Pin rotated.
The unit stops and an
error code (PE002, 003,
004) is displayed.
The arm is
stopped at an odd
angle.
The arm may have been left
out of position after mainte
-
nance, etc.
Return the arm to the correct
start position (by hand), then
restart the unit.
The arm was
started in the
correct position,
but stopped out of
position.
There is an internal problem
with the unit.
Notify the Company, then
return the unit for servicing.
Affixing the Fruit to the
Holding Prong
I’m afraid of stabbing
my hand.
--
Is your palm facing the hold
-
ing pin?
Encircle the item with your
hands, then safely press it
down.
Can’t affix/hard to affix
an item to the prong.
--
Is the item hard?
We prepare parts for harder
items. Please contact us.
--
Did you cut the item before
affixing, and adjust the affix
-
ing position?
Please read the manual, and
prepare the item before affix
-
ing.
Peeling
“Armmisaligned –
realign” is displayed.
--
The Arm is not in the correct
start position.
Return the arm to the starting
position, and press “Start.”
Skin remains after peel
-
ing.
The skin peels off
in a striped pat
-
tern.
The peeling thickness setting
is incorrect.
Making the peeling adjust
-
ment thicker will prevent
striping.
Concave portion
unpeeled
The peeling thickness or spin
speed setting is incorrect.
Increase the peeling
thicknes, and slow the spin
speed to leave less peel.
Targeted part
remains unpeeled.
Certain shapes cannot be
peeled by the blade.
You need to cut off the elon
-
gated part before peeling.
It is possible that part of the
blade is worn.
Polish the blade edge using
the polishing stone, or
replace the peeler blade with
a new one.
Fuzz appears on
the surface.
It is possible that blade edge
is worn.