5.7 Periodical inspection
6.2 Schematic Pneumatic Circuit
The lift must be inspected by a specialist at least once every 12 months.
Here are the inspection points:
Mechanic system
Pneumatic system
· Review of all the points of union between scissors (seeger and bolts).
· Tighten all existing nuts.
· Check the welds for cracks or deformations.
· Check the readability of the adhesives.
· Review of all pneumatic ducts in search of leaks, cracks, deformations or any deterioration
symbol.
NOTE
We recommend that you keep an exhaustive control of elevator inspections in the “inspec-
tion log” that can be found on page 20 of the manual.
6.1 Technical data
Maximum load admitted
Maximum height from the ground
Minimum height from the ground
Maximum width
Minimum length
Long maximum
Weight of the structure with accessories
Pneumatic circuit pressure
Ascent time
Descent time
2200 Kg
550 mm
123 mm
634 mm
1630 mm
2180 mm
160 Kg
6 a 8 BAR
13 seconds
17 seconds
6 Technical description
figure 28
16
USER MANUAL
·
AE100L MINILIFT&MOVE
Содержание miniLIFT&move
Страница 2: ......
Страница 17: ...6 3 Exploded view figure 29 17 USER MANUAL AE100L MINILIFT MOVE ...
Страница 19: ...figure 31 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 42 41 44 19 USER MANUAL AE100L MINILIFT MOVE ...
Страница 24: ...Date Maintenance plan Result Signature 7 Inspections log 24 USER MANUAL AE100L MINILIFT MOVE ...
Страница 25: ...Date Maintenance Plan Result Signature 25 USER MANUAL AE100L MINILIFT MOVE ...
Страница 26: ...Date Maintenance Plan Result Signature 26 USER MANUAL AE100L MINILIFT MOVE ...
Страница 27: ......
Страница 28: ...2018 astraballero com Spray booths Welding Benches Lifts ...