6
Note:
•
Do not cover the FOUNTAIN light body with any kind of temperature isolating material.
The FOUNTAIN light is protected by a temperature sensor against over-heating. When the
temperature of the FOUNTAIN light exceeds 85°C the FOUNTAIN light is automatically
switched off.
CONNECTION
The power supply has to be connected through the main switch (not included) with correct polarity
and protected by a fuse (not included). The power supply voltage has to be from 10 - 30Vdc.
Note:
•
The power supply has to be switched off before installation.
The underwater light has to be connected as described in the table below:
CASCADA
wire color
FUNCTION
Red
+ DC Power Supply
Black
GND Power Supply
Orange
+ Control
Brown
GND Control
For basic control of the light the CONTROL wire has to be connected through the momentary switch
(not included) to the GND by using a 2-pole signal cable extension. (not included)
For DMX512 control optional LXU01 or LXU03 interface can be connected to the CONTROL and
GND wires by using a 2-pole signal cable (not included).
Note:
•
When two or more lights are connected in the lighting system the control wires (red) can
be connected in parallel and all the lights then can be controlled by using only one
momentary switch or LXU01 (LXU03) interface.
Earthing
The fountain light has to be earthed by using a pre-tinned green wire with a yellow stripe a minimum
of 8 AWG (8.36 mm
2
). The wire has to be connected to the path light by the help of one fixing screw
M8x60
Synchronization
When more than one light is connected to the system the optional Synchronization Unit LSU08 is
recommended to synchronize the colors of lighting at the Rainbow Color Spectrum mode of lighting.
On the other case the colors of all installed lights would not be the same after few minutes or hours of
operation in the Rainbow Color Spectrum mode.
If the multi-color RGB light is used only with one of the fixed color of lighting the synchronization is
not necessary.