AG100 Operating Instructions Rev 1.1

Warranty

Workmanship - AST, Inc. pressure transmitters have a limited one-year warranty to the original purchaser.  AST, Inc. will replace or repair, 

free of charge, any defective transmitter.  This warranty does not apply to any units that have been modified; misused, neglected or installed 

where the application exceeds published ratings. AST’s sensors are made with pride in New Jersey, USA. If in the area please feel free to 

stop by for a visit!

Installation/Applications

 - The purchaser is responsible for media compatibility, functional adequacy, and correct installation of the transmitter.

TM

ON OFF 

Press and release this button to turn the AccuGauge ON. Press and 

hold this button to turn the AccuGauge OFF. When the AccuGauge 

is ON press and release this button to turn on the backlight.  The 

AccuGauge will automatically turn OFF after one hour to conserve 

battery power.

BACKLIGHT 

The backlight of the AccuGauge will illuminate the LCD display for 

10 seconds anytime one of the four buttons is   pressed.  To turn on 

the backlight without changing the display, press and release the 

ON/OFF button.

UNITS   

Press the UNITS button to cycle through the units of measurement 

the AccuGauge can display. The AccuGauge can measure pressure 

in PSI, BAR, Kg/cm2, Inches Hg, Inches H

2

O and ATM.  The unit 

of measurement can be changed at any time and will not affect the 

operation of the AccuGauge.

RELATIVE PRESSURE

Press and release the ZERO button to place the AccuGauge in 

relative pressure mode.  The REL symbol will be displayed at the 

top of the LCD to indicate the gauge is operating in relative pres-

sure mode.  The display will rezero at the applied pressure that 

was acting on the Gauge at the moment the button is pressed and 

display pressure re/- relative to that pressure.  Press this 

button again to return to GAUGE mode of operation, which displays 

pressure relative to the local pressure.  

ZERO

Over the course of time it may become necessary to reset the Accu-

Gauge to zero.  Press and hold the ZERO button until the REL sym-

bol appears and disappears and the display reads zero pressure in 

the selected units of measurement.  Release the ZERO button and 

the display will read zero pressure in the current units selected.

MIN MAX 

The MIN MAX button allows the user to read the minimum and 

maximum pressure the AccuGauge has detected during the time 

that the gauge has been on.  These readings are not saved and 

reset every time the gauge is powered off.  Press the MIN MAX 

button once and the MIN symbol will be displayed along with the 

minimum pressure, press the MIN MAX button again and the MAX 

symbol will be displayed along with the maximum pressure.  Press 

the MIN MAX button again and the MAX symbol will disappear and 

the gauge will display the current pressure.  Press and hold the MIN 

MAX button to reset the minimum and maximum pressure readings.

LOW BATTERY 

The AccuGauge has a battery condition indicator in the upper left 

corner of the LCD display. The indicator is composed of a battery 

symbol and four vertical bars.  As the battery discharges the verti-

cal bars will disappear from right to left. When all four bars have 

disappeared the battery is nearly discharged.  As a final warning 

the symbol LOW BAT will be displayed and indicates the battery is 

nearing complete discharge and should be changed immediately.  

For best results replace the battery immediately.  Use only Alkaline 

or Lithium 9V batteries.

BATTERY REPLACEMENT

(NOTE: DO NOT open the AccuGauge unless it is necessary to 

change the Battery.) To replace the AccuGauge’s Battery, use 

a Phillips Head screwdriver to remove the four screws from the 

back plate of the gauge.  Unplug the battery cable from the battery 

terminals.  Remove the battery from the battery holder.  Put a new 

battery into the holder, ensuring that it is firmly in place.  Plug the 

battery cable into the terminals of the battery.  Make sure that the 

polarity is correct.  Replace the cover firmly in place.  Replace the 

four screws.  