background image

Adding multiple tests to the same screen automatically creates a multiple step test 
sequence.

 Note:

 

The test will run in a sequential order unless Single Step control is set to ON.

Test programs can be saved and loaded as files for easy recall of test conditions.

4

5

TEST SETUP

SET TEST SEQUENCES

CREATE A NEW TEST FILE

SET TEST SEQUENCES

DELETE A TEST STEP

START

Select the Single Step soft key 

to  toggle ON or OFF.

To perform a Single Step test, 

select the Perform Tests soft key.

1

2

ABC

3

DEF

4

5

JKL

GHI

6

MNO

7

8

TUV

PQRS

9

EXIT

ENTER

WXYZ

0

<

- -

My

Menu

MENU

Setup  System

Setup  Tests

Perform  Tests

VERI-CKEK

Information

OMNIA   II    8257

My

Menu

MENU

Setup  System

Setup  Tests

Perform  Tests

VERI-CKEK

Information

OMNIA   II    8257

My

Menu

0002  IR      Settings

    500V       0.00M

    0.5s         0.05M

File Name: 0001

PERFORM  TESTS

0001  ACW  Settings

    1240V      10.00mA

    1.0s          0.000mA

Single Step

Fail Stop

Load Files

Results

OFF

ON

Select the EXIT key.

You will return to the Main Menu.

My

Menu

0002  IR      Settings

    500V       0.00M

    0.5s         0.05M

File Name: 0001

PERFORM  TESTS

0001  ACW  Settings

    1240V      10.00mA

    1.0s          0.000mA

Single Step

Fail Stop

Load Files

Results

ON

ON

START

From the Main Menu select

the Setup Tests soft key.

Select the File soft key.

Select the New File soft key.

My

Menu

MENU

Setup  System

Setup  Tests

Perform  Tests

VERI-CKEK

Information

OMNIA   II    8257

My

Menu

My

Menu

0001 

Add

Edit

Delete

Prompt

File

Fail  Stop ON

SETUP  TESTS

This returns you to the Setup Tests

menu with a blank sequence. The

file name is displayed at the bottom.

You may begin setting up a full test 

sequence by selecting the Add soft key.

My

Menu

File  Name:  0002  TEST

Add

Edit

Delete

Prompt

File

Fail  Stop ON

SETUP  TESTS

0002  

File  Name:

New File

Save

Save  As

Delete

Load

FILE  SETUP

Use the alpha/numeric key pad to give 

the file a name. Select ENTER to save.

1

2

ABC

3

DEF

4

5

JKL

GHI

6

MNO

7

8

TUV

PQRS

9

EXIT

ENTER

WXYZ

0

<

- -

My

Menu

CREATE FILE

Caps Lock

Symbol Key

ON

File Name:

My

Menu

File  Name:  0002  TEST

Add

Edit

Delete

Prompt

File

Fail  Stop ON

SETUP  TESTS

0002 TEST

0001 

0002

0002

0001 

START

From the Main Menu select

the Setup Tests soft key.

If a test file is not already loaded, 

load a file by selecting the File 

soft key.

Use the arrow keys to choose the file.

Select the Load soft key to load the file.

My

Menu

MENU

Setup  System

Setup  Tests

Perform  Tests

VERI-CKEK

Information

OMNIA   II    8257

My

Menu

My

Menu

1

2

ABC

3

DEF

4

5

JKL

GHI

6

MNO

7

8

TUV

PQRS

9

EXIT

ENTER

WXYZ

0

<

- -

File  Name:  0001  TEST

0001 ACW Settings

  1240 V  10.00mA

  1.0s       0.000mA 

Add

Edit

Delete

Prompt

File

Fail  Stop ON

SETUP  TESTS

0001  

0002 TEST

0003 SEAN
0004 

File  Name:

New File

Save

Save  As

Delete

Load

FILE  SETUP

The test file is loaded.

My

Menu

File  Name:  0002  TEST

Single Step

Fail Stop

Load Files

Results

OFF

ON

PERFORM TESTS

0002 LLT Settings

                10000uA

  0.5s       0.0uA 

0001 ACW Settings

  1240 V  10.00mA

  1.0s       0.000mA 

START

From the Main Menu select 

the Setup Tests soft key.

If a test file is not already loaded, 

load a file by selecting the File 

soft key.

Select the Load soft key to load the file.

Use the arrows to select the test 

you would like to delete. Select 

the delete soft key to delete the 

Test Step.

My

Menu

MENU

Setup  System

Setup  Tests

Perform  Tests

VERI-CKEK

Information

OMNIA   II    8257

My

Menu

My

Menu

1

2

ABC

3

DEF

4

5

JKL

GHI

6

MNO

7

8

TUV

PQRS

9

EXIT

ENTER

WXYZ

0

<

- -

File  Name:  0001  TEST

0001 ACW Settings

  1240 V  10.00mA

  1.0s       0.000mA 

Add

Edit

Delete

Prompt

File

Fail  Stop

ON

SETUP  TESTS

0001  
0002 TEST

0003 SEAN

0004 

File  Name:

New File

Save

Save  As

Delete

Load

FILE  SETUP

My

Menu

0001  
0002 TEST

0003 SEAN

0004 

File  Name:

New File

Save

Save  As

Delete

Load

FILE  SETUP

Содержание OMNIA II 8204/8254

Страница 1: ...ch clips directly and always connect the return lead first You should always know when a test is being performed WARNING THISGUIDEWASCREATEDFOROPERATORSHAVINGSOMEFAMILIARITYWITHELECTRICALSAFETY TESTING AN ELECTRICAL SAFETY TESTER PRODUCES VOLTAGES AND CURRENTS THAT CAN CAUSE HARMFUL OR FATAL ELECTRIC SHOCK TO PREVENT ACCIDENTAL INJURY OR DEATH THESE SAFETY PROCEDURES MUST BE STRICTLY OBSERVED WHEN...

Страница 2: ...C WITHSTAND Voltage HI Limit Total LO Limit Total Ramp Up Dwell Time Ramp Down Frequency Arc Detect 1240 V 10 00mA 1 0s 5 0 00mA 10 00mA 0 00mA 0 00mA 0 1s 0 0s 60Hz OFF Arc Sense HI Limit Real LO Limit Real Offset Step Name Defaults More Enter the value for each parameter by using the alpha numeric key pad Select ENTER to save and go to the next parameter 1 2 ABC 3 DEF 4 5 JKL GHI 6 MNO 7 8 TUV P...

Страница 3: ...Save As Delete Load FILE SETUP Use the alpha numeric key pad to give the file a name Select ENTER to save 1 2 ABC 3 DEF 4 5 JKL GHI 6 MNO 7 8 TUV PQRS 9 EXIT ENTER WXYZ 0 My Menu CREATE FILE Caps Lock Symbol Key ON File Name My Menu File Name 0002 TEST Add Edit Delete Prompt File Fail Stop ON SETUP TESTS 0002 TEST 0001 0002 0002 0001 START From the Main Menu select the Setup Tests soft key If a te...

Страница 4: ...est Using the output ports on the rear panel plug the black high voltage lead in the High Voltage terminal Plug the sense lead into the Sense terminal Plug the high current test lead into the Current terminal These two red leads act as the ground connection Connect the ground return clip P N 38490 to the dead metal on the chassis of the DUT Plug the sense lead into the Sense terminal Plug the retu...

Страница 5: ... ACW Settings 1240 V 10 00mA 1 0s 0 000mA My Menu File Name 0002 TEST RESULTS 0002 LLT Settings 10000uA 0 5s 0 0uA 0001 ACW Settings 1240 V 10 00mA 1 0s 0 000mA 0002 LLT Settings 10000uA 0 5s 0 0uA PERFORM TESTS 1 2 ABC 3 DEF 4 5 JKL GHI 6 MNO 7 8 TUV PQRS 9 EXIT ENTER WXYZ 0 My Menu File Name 0002 TEST Single Step Fail Stop Load Files Results OFF ON 0001 ACW Settings 1240 V 10 00mA 1 0s 0 000mA 0...

Отзывы: