background image

SAFETY CHECKLIST

Quick Start Guide

HypotULTRA

®

for the following models: 7800, 7820, 7850

EN 61010-1
EN 61010-31

WARNING: THIS GUIDE WAS CREATED FOR OPERATORS HAVING SOME FAMILIARITY WITH ELECTRICAL 

SAFETY TESTING. AN ELECTRICAL SAFETY TESTER PRODUCES VOLTAGES AND CURRENTS THAT CAN 

CAUSE HARMFUL OR FATAL ELECTRIC SHOCK. TO PREVENT ACCIDENTAL INJURY OR DEATH, THESE 

SAFETY PROCEDURES MUST BE STRICTLY OBSERVED WHEN HANDLING AND USING A TEST INSTRUMENT. 

CONTACT US AT [email protected] FOR MORE INFO ON HOW TO GET TRAINED ON ELECTRICAL 

SAFETY TESTING.

S

urvey the test station. Make sure it is safe & orderly.

A

lways keep unqualified/unauthorized personnel away from the test area.

F

amiliarize yourself with safety protocols in the event of a problem.

E

xercise caution and never touch products or connections during a test.

T

rain operators. Never touch clips directly & always connect the return lead first.

Y

ou should always know when a test is being performed.

Содержание HypotULTRA 7800

Страница 1: ...CEDURES MUST BE STRICTLY OBSERVED WHEN HANDLING AND USING A TEST INSTRUMENT CONTACT US AT INFO ARISAFETY COM FOR MORE INFO ON HOW TO GET TRAINED ON ELECTRICAL SAFETY TESTING Survey the test station Make sure it is safe orderly Always keep unqualified unauthorized personnel away from the test area Familiarize yourself with safety protocols in the event of a problem Exercise caution and never touch ...

Страница 2: ... end of the cord into a grounded power source Connect the Interlock Disable Key to the Signal Input connector on the back panel of the instrument if you re not utilizing a DUT enclosure P N 39064 or 39656 or other safety device This is required in order to run a test Back Home Test Screen Turn the instrument power switch ON To Grounded Power Source WARNING LOCATE A SUITABLE TESTING AREA WITH A CLA...

Страница 3: ...er box provides an easy way to connect the HypotULTRA to a device under test DUT terminated in a two or three prong power cord The following diagram shows how to connect the adapter box to the HypotULTRA and to the DUT Note If you need to perform a Ground Continuity test be sure you enable the Ground Continuity test type before moving forward CAUTIONHIGH VOLTAGE 5KVAC MAX 6KVDC MAX N L DO NOT TOUC...

Страница 4: ...he DUT and the return clip Attach the high voltage lead P N 4040A 08 to the current carrying conductors of the DUT After you make the proper connections you can initiate a test from the front panel of the HypotULTRA by pressing the green TEST button Press the red RESET button to abort a test in process TAP PERFORM TESTS OR TAP TEST SCREEN BUTTON AT THE BOTTOM OF THE TOUCH SCREEN PUSH THE TEST BUTT...

Страница 5: ...information about these and other key features of the HypotULTRA please consult the full Operation and Service Manual or call us toll free 1 800 TEST 8378 or 1 847 367 4077 2017 Associated Research www arisafety com SCAN FOR QUICK START VIDEO v1 2 7 17 ...

Отзывы: