Associated Equipment BCH7109A Скачать руководство пользователя страница 3

3

20.

GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS

The charger should be grounded to reduce the risk of electric shock.  This charger is equipped with an electric cord having an equipment
grounding conductor and a grounding plug.  The plug must be plugged into an outlet that is properly installed and grounded in accordance
with all local codes and ordinances.

DANGER.

  Never alter the AC cord or plug provided - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. 

Improper connection can result in a risk of an electric shock.  This battery charger is for use on a nominal 120-volt circuit, and has a
grounding plug that looks like the plug illustrated in FIGURE (A).  A temporary adapter, which looks like the adapter illustrated in FIGURE
(C), may be used to connect this plug to a two-pole receptacle, as shown in FIGURE (B), until a properly grounded outlet can be installed
by a qualified electrician.

DANGER.

  Before using an adapter as illustrated, be certain that the center screw of the outlet plate is grounded.  The green-colored

rigid ear or lug extending from the adapter must be connected to a properly grounded outlet - make certain it is grounded.  If necessary,
replace the original outlet cover plate screw with a longer screw that will secure the adapter ear or lug  to the outlet cover plate and make
ground connection to grounded outlet.
NOTE:

USE OF AN ADAPTER IS NOT ALLOWED IN CANADA.  IF A GROUNDING TYPE RECEPTACLE IS NOT AVAILABLE, DO
NOT USE THIS APPLIANCE UNTIL THE PROPER OUTLET IS INSTALLED BY A QUALIFIED ELECTRICIAN.

21.

LENGTH OF CHARGE

a.

Test the battery for state of charge.  Do not charge if it is over 75% charged or the battery is determined to be defective.

b.

Set beginning amps charge rate for size of battery and state of charge per charts

c.

Charge for length of time per charge,

d.

Discontinue charge when the specific gravity of electrolyte reaches 1.260 or above.  A temperature compensating hydrometer should
be used for this reading.  Discontinue charge if the battery begins to gas excessively or when the temperature of the electrolyte
reaches approximately 120

E

F.  Do not overcharge batteries.  Overcharging results in excessive water loss and eventual damage to

the battery.

ASSEMBLY INSTRUCTIONS

1.

Remove the screws from the back of the charger and attach the handle in an upright position
with the screws provided.

2.

Remove the four screws on the bottom toward the front of the charger and attach the leg with
the screws provided.

3.

Put one of the axle nuts on one side of the axle by tapping the nut on with a hammer.  Then
slide the axle through one of the wheels and then through the hole in the charger until it
comes out the other end.  Put the other wheel and axle on.

4.

Attach the clamp bar to the handle with two 10-16x1-1/2 screws included in the hardware
bag.

Содержание BCH7109A

Страница 1: ...quipment you intend to use in vicinity of the battery Review cautionary markings on these products and on the engine 13 PERSONAL PRECAUTIONS a Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery b Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes c Wear complete eye protection and cloth...

Страница 2: ...assis as in most vehicles see item e If the positive post is grounded to the chassis see item f f For negative grounded vehicles connect the POSITIVE RED clamp from the battery charger to the POSITIVE POS P ungrounded post of the battery Touch the contact button of the STOP GO LITE to the NEGATIVE NEG N battery post Interpret the light and take appropriate action When the green light is on connect...

Страница 3: ...e outlet cover plate and make ground connection to grounded outlet NOTE USE OF AN ADAPTER IS NOT ALLOWED IN CANADA IF A GROUNDING TYPE RECEPTACLE IS NOT AVAILABLE DO NOT USE THIS APPLIANCE UNTIL THE PROPER OUTLET IS INSTALLED BY A QUALIFIED ELECTRICIAN 21 LENGTH OF CHARGE a Test the battery for state of charge Do not charge if it is over 75 charged or the battery is determined to be defective b Se...

Страница 4: ... the switch to OFF and remove the AC power cord from the electric outlet before disconnecting the DC clamps CHARGING SULFATED BATTERIES If your battery has sat in the discharged state for an extended period of time it can become SULFATED This usually is seen as a white deposit near the top of the battery The sulfate is formed when a battery with low water levels remains discharged for an extended ...

Страница 5: ... phone Minimum order from the factory is 25 00 Orders received that are under the minimum will not be processed Taxes and freight are extra and are not considered to be part of the dollar value of the order We do not have a C O D policy Cashier check Money order Mastercard or VISA are acceptable If you use a Mastercard or VISA send only the number and expiration DO NOT SEND THE CARD MAINTENANCE IN...

Страница 6: ...GROUNDING ADAPTER ENGLISH 5 ENGLSTBL PLT CHARGE RATE TABLE ENGLISH 6 27 600A PLT BCH7109A CHARGER 7 6009B E PLT 6009 WIRING DIAGRAM ENGLISH Revision record 01 98 Add note 4 clamp bar attachment to assembly instructions Revise figure 6 graphic 27 600a plt to show clamp bar 06 01 Revise part list 610190 fan motor was 610696 610895 timer was 610555 610696 ac cord was 605206 610855 dc cable was 605207...

Отзывы: