DANGER

 - Before using adapter as illustrated, be certain that 

center screw of outlet plate is grounded. The green-colored rigid ear 

or lug extending from adapter must be connected to a properly 

grounded outlet-make certain it is grounded. If necessary, replace 

original outlet cover plate screw with a longer screw that will secure 
adapter ear or lug to outlet cover plate and make ground connection 

to grounded outlet. 

 

9

 

OPERATING INSTRUCTIONS 

Once the connection instructions have been followed, the Red 

'POWER' Light Emitting Diode (L.E.D.) lights when A.C. Power is 

present. The Yellow 'CHARGING' L.E.D. then flashes to indicate 

'Battery connected' and battery voltage greater than the 'Charging 

Starting Voltage'.  The 'Charging Mode' begins when the Yellow 

'CHARGING' L.E.D. is on continuously and charges the battery to 
approximately (14.5Vdc Lead-acid battery Mode) or (14.1Vdc GEL 

battery Mode) and the charging current reaches approximately 

300mA.  Then the charger will transit to 'Float Mode' where the 

Green 'CHARGED/MAINTAINING' L.E.D. illuminates.  If the battery 

voltage reaches approximately (14.5Vdc Lead-acid battery Mode) 

or (14.1Vdc GEL battery Mode) but the charging current does not 
reach approximately 300mA in 120 minutes, the charger will be 

forced to 'Float Mode'.

 

The regulating voltage is then reduced to a 

lower level. The Float Mode allows the charger to effectively be left 

connected to your batteries, over the course of a season, without 

overcharging your batteries, and maintains your battery's full 

charge. A regular, periodic check on your charging system, if left 
unattended and powered, is still recommended (just as you would 

with any electrical appliance). 

Remark:  

1.

 

LEAD ACID/ GEL battery selectable switch 

The LEAD ACID battery mode or GEL battery mode are 

selected by a slide switch. When you slide the switch to left-hand 
side, GEL battery is selected. When you slide the switch to right 

hand side, LEAD ACID battery is selected. The battery mode 

should be properly selected, otherwise the battery cannot be fully 

charged. 

2.

 

The charging current selectable switch 

The charging current can be changed to 800mA or 2A by a 

switch.  For 800mA current mode, the charger is recommended for 

charging maximum 20 AHr. LEAD ACID/GEL battery. For 2A 

current mode, the charger is recommended for charging maximum 

45 AHr. LEAD ACID/GEL battery.   

10

 

REVERSE BATTERY /SHORT CIRCUIT/ OVERLOAD 
PROTECTION. 

The charger has reverse polarity of the battery and short circuit 

protection. If a reverse battery or charger output lead short 

condition exists (the Red 'POWER' L.E.D. flashes, while output 

leads are connected backwards), simply unplug charger from AC 
power and properly remake the connections as described in this 

manual. The charger employs the use of thermal fuse at the 

primary of the transformer that will permanently open during a 

overheat condition. Besides, the charger employs a ceramic or 

glass tube fuse at output section that will permanently open during 

overload condition. 

11

 

MAINTENANCE 

Store in a clean, dry place. Occasionally, clean the case and cords 

with a dry cloth. 

away from battery keeping the battery terminal well removed there 
from. 

6.7

 

Do not connect any charger clips to carburetor, fuel lines, or 

sheet-metal body parts.  Connect to a heavy gauge metal part of 

the frame or engine block. 

6.8

 

When disconnecting charger, turn switches (if supplied) to off, 

disconnect charger from AC power, remove clip from vehicle 
chassis, and then remove clip from battery terminal. See operating 

instructions for length of charge information. 

7

 

FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE 

VEHICLE.  A SPARK NEAR THE BATTERY MAY CAUSE 

BATTERY EXPLOSION.  TO REDUCE RISK OF A SPARK NEAR 

BATTERY: 

7.1

 

Check polarity of battery posts.  POSITIVE (POS., P, +) battery 

post usually has a larger diameter than NEGATIVE (NEG., N, -) 

post.  Some batteries are equipped with 'Wing-Nut' terminals 

allowing for easy placement of the terminals to these posts. 

7.2

 

Attach at least a 24-inch long 18-gauge (AWG) insulated battery 

cable to NEGATIVE (NEG., N, -) battery post. 

7.3

 

Connect POSITIVE (RED) charger terminal to POSITIVE (POS., P, 

+) post of battery. 

7.4

 

Position yourself and free end of cable as far away from battery as 

possible - then connect NEGATIVE (BLACK) terminal to free end of 

cable. 

7.5

 

Do not face battery when making final connection. 

7.6

 

When disconnecting charger, always do so in reverse sequence of 

connecting procedure and break first connection while as far away 

from battery as practical 

7.7

 

A marine (boat) battery must be removed and charged on shore.  

To charge it on board requires equipment specially designed for 

marine use. 

 

8

 

Instructions for grounded cord-connected battery 
chargers: 

8.1

 

For all grounded cord-connected battery chargers: 

GROUNDING AND AC POWER CORD CONNECTION 

INSTRUCTIONS-  Charger should be grounded to reduce risk of 

electric shock. Charger is equipped with an electric cord having an 

equipment-grounding conductor and a grounding plug. The plug 

must be plugged into an outlet that is properly installed and 

grounded in accordance with all local codes and ordinances. 
DANGER – Never alter AC cord and plug provided- if it will not fit 

outlet, have proper outlet installed by a qualified electrician. 

Improper connection can result in a risk of an electric shock. 

8.2

 

For grounded, cord-connected battery chargers with an input rating 

less than 15 amperes and intended for use on a nominal 120-volt 

circuit. 

This battery charger is for use on a nominal 120-volt circuit, and has 

a grounding plug that looks like the plug illustrated in sketch A in 

Figure 1. A temporary adapter, which looks like the adapter 

illustrated in sketches B and C, may be used to connect this plug to 

a two-pole receptacle as shown in sketch B if a properly grounded 

outlet is not available. The temporary adapter should be used only 
until a qualified electrician can install a properly grounded outlet. 

Fig. 1 

 

Содержание 9004

Страница 1: ...like to metal causing a severe burn 2 6 Use charger for charging a Lead Acid Gel Battery only It is not intended to supply power to a low voltage electrical system other than in a starter motor application Do not use battery charger for charging dry cell batteries that are commonly used with home appliances These batteries may burst and cause injury to persons and damage to property 2 7 NEVER char...

Страница 2: ...ndition Besides the charger employs a ceramic or glass tube fuse at output section that will permanently open during overload condition 11 MAINTENANCE Store in a clean dry place Occasionally clean the case and cords with a dry cloth away from battery keeping the battery terminal well removed there from 6 7 Do not connect any charger clips to carburetor fuel lines or sheet metal body parts Connect ...

Страница 3: ... plomb acide peut créer un court circuit assez puissant pour souder de tels articles menant à une brûlure grave 2 6 Utilisez le chargeur uniquement pour charger des batteries au plomb acide Il n est pas prévu pour fournir une source de courant à un système à basse tension sauf que dans une application de démarrage d un moteur N utilisez pas le chargeur pour charger des piles sèches utilisées coura...

Страница 4: ...aucune prise correctement à la terre n est disponible Utilisez uniquement l adaptateur temporaire le temps qu un électricien qualifié mette en place une installation à la terre correcte Fig 1 DANGER Avant d utiliser la prise comme indiqué assurez vous que la vis centrale présente sur la plaque de la prise est à la terre La pièce métallique rigide verte ou cosse qui part de la prise doit être branc...

Страница 5: ... el cargador para cargar batería de pilas secas que se usan comúnmente en los artefactos del hogar Estas batería podrían reventarse y provocar daños personales y a la propiedad 2 7 NUNCA cargue una batería congelada 3 PREPARACIÓN PARA EL CARGADO 3 1 Si es necesario sacar la batería del vehículo para cargarla siempre quite el terminal a tierra de la batería primero Asegúrese de que todos los acceso...

Страница 6: ...está puest a tierra En caso de que sea necesario cambie el tornillo orginal de la tapa de la toma por un tornillo más largo que mantenga bien unida la oreja del adaptador a la tapa del la toma y conecte a tierra la toma de tierra 9 INSTRUCCIONES DE FUNCIONAMIENTO Una vez completadas las instrucciones para la conexiόn se enciende el diodo emisor de luz LED rojo de Encendido cuando recibe la corrien...