    Resetting Lock to Factory Default

When lock is reset to factory defaults all user 
codes (including the Master PIN code*) are 
deleted and all programming features are reset to 
original default settings (see "Factory Default 
Settings").

1. Remove the battery cover.
2. Remove the batteries.
3. While pressing the reset button (minimum of 3 

seconds) reinstall batteries. Release reset 
button.

4. Replace battery cover.

Upon reset, Master Code creation is the only 
option available and must be performed prior to 
any other programming of the lock. 
NOTE: After setting the Master Code, press any 
key to complete handing of the lock.

    Enrolling Lock In                 Network 

®

 

Your network controller first needs to be in 
enrollment or exclusion mode for the lock to be 
enrolled or removed from network. 

2. Press    button and hold until unit beeps two (2) 

times.

Once you put the controller in the enrollment or 
exclusion mode, the lock can be enrolled or 

®

removed in the Z-Wave  network two ways - 
through the keypad using the #7 key (see 
Programming Through Menu Mode) or by 
pressing the    button.

1. Remove the battery cover.

To remove lock using the    button option:

To enroll lock using the    button option:
1. Remove the battery cover.

2. Press    button and hold until unit beeps five (5) 

times.

4. Replace battery cover.

3. Release button and network joining 

automatically begins.

3. Release button and network removal 

automatically begins.

4. Replace battery cover.

Содержание Yale Real Living B1L Z-Wave

Страница 1: ...h WAVE x3 8 32 x 5 16 Machine screws x4 7 wood 8 32 machine x 20mm Combination screws x2 M6x47mm Long through bolt FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE PRODUCT AND VOID T...

Страница 2: ...2 P N AYRD 110 INST FUL Rev G Preparing Door...

Страница 3: ...N AYRD 110 INST FUL Rev G O x4 1 defaut 2 3 8 position 2 3 4 position Installing Latch Strike Plate Press Pull optional Bolt must be in retracted unlocked position Note horizontal orientation of mecha...

Страница 4: ...4 P N AYRD 110 INST FUL Rev G 2 Installing Keypad Escutcheon Outside of Door Inside of Door Bolt must be in retracted unlocked position Note horizontal orientation of mechanism...

Страница 5: ...5 P N AYRD 110 INST FUL Rev G x2 3 Installing Interior Mounting Plate Loosen screw to remove cover...

Страница 6: ...4 Attaching the Cable Assembly 6 P N AYRD 110 INST FUL Rev G...

Страница 7: ...7 P N AYRD 110 INST FUL Rev G x3 5 Installing Interior Escutcheon...

Страница 8: ...8 P N AYRD 110 INST FUL Rev G Testing Operation Bolt must be in retracted unlocked position before installing AA batteries...

Страница 9: ...9 P N AYRD 110 INST FUL Rev G Handing the Lock Press Press Press Enter new Master PIN code 4 8 digits Press to complete After entering the Master PIN code press any key to complete handing...

Страница 10: ...N AYRD 110 INST FUL Rev G 6 Installing Cover Congratulations you ve installed the Yale Real Living Key Free Push Button Deadbolt B1L with Continue with Programming Instructions to customize your prod...

Страница 11: ...ine battery Master PIN Code must be created before any further programming Max User Codes 100 Warning Changes or modi cations to this device not expressly approved by Yale Security Inc could void the...

Страница 12: ...1 Creating Master PIN Code Press Press Press Enter 4 8 digit Master PIN Code Press 12 P N AYRD 110 INST FUL Rev G...

Страница 13: ...2 Creating User PIN Codes Master PIN code must be created rst Max User Codes 100 Enter Master PIN code Press Enter 4 8 digit PIN code Press Press Press Press Press 13 P N AYRD 110 INST FUL Rev G...

Страница 14: ...ress User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ PIN Code Management With Network Module Up to 100 Users Duplicate if necessary User Name User PIN Code Master User...

Страница 15: ...complete handing of the lock Enrolling Lock In Network Your network controller rst needs to be in enrollment or exclusion mode for the lock to be enrolled or removed from network 2 Press button and ho...

Страница 16: ...secure This feature is optional and can be turned off In the ON mode the lock will automatically re lock after thirty 30 seconds Low Battery When battery power is low the Status Indicator ashes RED I...

Страница 17: ...select Disable 3 in Audio Mode 1 Enter the 4 8 digit Master PIN code followed by the key 2 Enter digit corresponding to the function to be performed followed by the key Factory Settings Settings Fact...

Страница 18: ...will not register PIN codes must consist of 4 to 8 digits to register The same PIN code cannot be used for multiple users Registration management of PIN codes is set by the authority of the Master Co...

Страница 19: ...des r glements d quipement L op ration est sujette aux deux conditions suivantes 1 ce dispositif peut ne pas causer l interf rence nocive et 2 ce dispositif doit accepter n importe quelle interf renc...

Страница 20: ...Y Residential Group Other products brand permission of ASSA ABLOY Residential Group is prohibited Product Support Tel 1 855 213 5841 www yalehome com NOTE TO INSTALLER AND CONSUMER While Yale has incl...

Отзывы: