56
ASSA ABLOY Hospitality
66 1000 023-4
Figure D14
- A more secure way; fix the cylinder in
place by using the fixing-screw tool kit.
Use the L-shaped Allen key to lock the
headless fixing screw (cylinder screw is
turned upside down) to the T-shaped tool
as illustrated in Figure D14. Using the
T-tool, screw the fixing screw in place as
shown earlier to fix the cylinder in place.
Make sure that the cylinder fixing screw
is tightened in the cylinder. Release the
T-tool from the fixing screw by holding
the T-tool rigid while turning the Allen
key counter-clockwise until the Allen
key is released from the screw; then
unscrew the T-tool.
12. After installation of the cylinder, fix for
ANSI (DA) and ANSI (DB) the face plate
to the lock case after installation of
the cylinder.
Figure D15
13. Assemble the
Essence cassette
(
8
)
before installation.
14. Depending on whether the handing
is left or right (see details
here
),
the fire shield plate shall be attached
on the opposite side of the LCU (the
drawing shows right handing).
15. Connect the Y-cable to the endnode
and LCU and also to the 7-pin connector
at the LCA
.
16. Snap the plastic cover with ZigBee
endnode inside onto the Essence cassette
until the locking mechanism locks.
17. When the lock case cable has been
connected, fasten the fire-retardant
material on the Essence cassette.
Note:
As stated at
Figure D1
, the
fire-retardant material is only needed
for European online installations.
The fire-retardant material is not
needed for UL rated online doors.