2.4.4.2.3
XPORT CONFIGURATION
Before configuring a Traka XPort Ethernet Device (TXED) you will need to obtain certain information from your
Network Administrator. Please refer to the
Once you have obtained the configuration details you can configure the TXED. The TXED can either be configured
using
within Traka32. If you are not experienced with networks we suggest you
ask your Network Administrator or Local Traka Engineer to set up the TXED.
Using Telnet
NOTE:
Windows Vista operating system does not have the Telnet client installed by default. Please refer to
Installing Telnet on Windows Vista
if using this operating system and have not already installed Telnet.
1.
Check that there is LED activity on the device. If there is no activity, check that there is power to the Control
PCB and that it is switched on and re-check your connections to the Control PCB, Wall Port, Patch Panels and
Ethernet Switch Hub.
2.
From a workstation that is connected to the network click on Start, Run and the following window will
appear…
In order to establish an initial connection with the device we must use the ARP method to create an entry in
the hosts ARP table. To do this, type the following in the Run window and click on OK…
arp -s IP-Address MAC-Address
The IP-Address is provided by your Network Administrator and the MAC-Address is printed on the label
attached to the device as shown.
For example if you wanted to assign an IP-Address of 10.0.0.254 to a device with an MAC-Address of 00-
20-4A-80-2C-A8, then I would type the following in the Run window and click on OK…
arp -s 10.0.0.254 00-20-4A-80-2C-A8
3.
Now we Telnet to the device using port 1 to create a temporary connection. To do this, again click on Start,
Run, type the following and click on OK…
telnet IP-Address 1
Following the above example you would type…
telnet 10.0.0.254 1
Содержание TRAKA32
Страница 220: ...V3 5 14 08 19 UD0089 Page 220 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 482: ...V3 5 14 08 19 UD0089 Page 482 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 587: ...V3 5 14 08 19 UD0089 Page 587 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 723: ...V3 5 14 08 19 UD0089 Page 723 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 748: ...V3 5 14 08 19 UD0089 Page 748 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 771: ...V3 5 14 08 19 UD0089 Page 771 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 796: ...V3 5 14 08 19 UD0089 Page 796 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 856: ...V3 5 14 08 19 UD0089 Page 856 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 857: ...V3 5 14 08 19 UD0089 Page 857 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 866: ...V3 5 14 08 19 UD0089 Page 866 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT Version 1 2 0 green ...
Страница 871: ...V3 5 14 08 19 UD0089 Page 871 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT RS 485 ...
Страница 895: ...V3 5 14 08 19 UD0089 Page 895 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 906: ...V3 5 14 08 19 UD0089 Page 906 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...