Assa Abloy Securitron WSS Скачать руководство пользователя страница 3

 

500-23710_1 

 

NOTE: Use either green (N.O.) or yellow (N.C.) wire, not both. Refer to the 

door control manual to determine which must be used. 

 

Setup 

NOTE:

  Four adjustments can be made to the sensor.   

1.  Sensitivity potentiometer: adjust detection field 

from 4 to 24 inches (rotate clockwise to 

increase)  

Factory default: 4 inches (fully CCW) 

2.  Hold time potentiometer: adjust relay hold time 

from 0.5 to 30 seconds (rotate clockwise to 

increase) 

Factory default: 0.5 sec (fully CCW) 

3.  Output Mode switch: determines Toggle mode 

or Timer mode 

 

Toggle (switch up) = detection activates 

the relay and the relay holds until a 

second detection deactivates the relay 

(recommended for switch applications) 

 

Timer (switch down, factory default) = detection activates the relay for 

0.5 to 30 seconds; relay will hold as long as detection occurs  

4.  LED mode switch: determines if LED illuminates when in detection or when 

not in detection 

 

switch up (factory default) = LED on when sensor is NOT in detection, 

LED off when in detection 

 

switch down = LED on when sensor is in detection, LED off when not 

in detection 

 
 

Troubleshooting 

PROBLEM: 

Door does not open when swiping hand in front of sensor.

 

CAUSE/ACTION:

 

1.  Bad or no power supply.  .  CHECK power supply.  If LED switches on 

or flashes, power connections are OK. 

 

2.  Detection range is too small.  ADJUST the detection range.  REMOVE 

any metal plates in front of sensor. 

 

3.  Wrong connection.  CHECK wiring and relay connection.

 

 

 
PROBLEM: 

Door remains permanently open.

 

CAUSE/ACTION:

 

1.  Environmental conditions are influencing the sensor.  REMOVE any 

moving objects close to the sensor. 

Содержание Securitron WSS

Страница 1: ...5 kg REGULATORY Electromagnetic compatibility EMC according to 2004 108 EC FCC G9B 21016 IC 4680A 21016 Precautions 1 SHUT OFF power to header before attempting any wiring procedures 2 MAINTAIN a clean and safe environment when working in public areas 3 Constantly BE AWARE of pedestrian traffic around the door area 4 Always STOP pedestrian traffic through the doorway when performing tests that may...

Страница 2: ...cable and depending on the type of door installation NOTE 1 The weather resistant foam is used as a protective barrier against the elements NOTE 2 The plastic adapter ring enables the double gang face plate to attach to various plastic and metal gang boxes NOTE 3 If using a metal electrical box do not allow contact between the sensor and the box to prevent shorting the device 2 ENSURE placement of...

Страница 3: ...tch down factory default detection activates the relay for 0 5 to 30 seconds relay will hold as long as detection occurs 4 LED mode switch determines if LED illuminates when in detection or when not in detection switch up factory default LED on when sensor is NOT in detection LED off when in detection switch down LED on when sensor is in detection LED off when not in detection Troubleshooting PROB...

Страница 4: ...lay connection FCC Approval This device complies with Part 15 of the FCC Rules and with RSS 210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation IMPORTANT NOTE Changes or modifications to this equipment that are no...

Отзывы: