![Assa Abloy Sargent 9700 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/assa-abloy/sargent-9700/sargent-9700_instructions-for-installing_2988930002.webp)
2
1
2
3
4
All 9700/12-9700 Exit Devices are not handed and can be used on
either hand door.
NOTE: Trim may or may not be handed
9700/12-9700 Vertical Rod Exit Device
Mark vertical centerline on inside of door
as follows:
A.
Where the lock stile is approx.
4-1/2" wide or wider - “A” = 2-3/4"
B.
On single doors where the width of lock
stile is under 4-1/2", make "A" equal to
1/2 the width of the exposed lock stile
(when door is closed against stop)
Finished floor
“A”
Inside
face of
door
Vertical CL of top, bottom & center case
Door
Stop
5/8"
Max
Locate and place templates as follows:
A.
With door closed, tape top case template
to inside of door along reference lines
marked in step 1
B.
Tape center case template to door in the
same manor (see dimension on template
to obtain correct height from finished floor)
C. Using cross bar hole centers for
measuring, locate vertical center line of
bracket (See dimensions on template to
obtain correct height from finished floor)
Door stop
Top case
template
Stop
thickness
Vertical CL of
top, bottom and
center case
Obtain dimensions
to finished floor
from template
Locate templates between mounting holes on cross bar
Horizontal CL of
bracket holes
Drill and cut holes as directed on template
Attach outside trim when used
A.
Some outside trims are through-bolted to the center
case. Trims of this type must be put on in conjunction
with step 5. Check outside trim used
B.
Check for correct spindle or thumb-piece length
C. Install key cylinder (check for correct tail piece length)
1/8" gap min. between
lever and chassis
Copyright © 2009, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
A5570G 5-5-09