Cylinder Installation (cont .)

Add or Remove Cylinder

3.  Remove insert assembly from rail by sliding toward rail end.

Figure 13 

 

Installation and Orientation of Cylinder

1.  Slide cylinder through collar into insert as shown.
2.  Note orientation of cylinder. 
3.  Secure cylinder with cylinder nut, tightening firmly.
4.  Operate cylinder and verify cam is operating switch properly.

Figure 14 

 

 

 

Figure 15 

 

Содержание SARGENT 5300 Series

Страница 1: ...sion of SARGENT Manufacturing Company is prohibited WARNING This product can expose you to lead which is known to the state of California to cause cancer and birth defects or other reproductive harm For more information go to www P65warnings ca gov 5300 Series Alarmed Exit Devices ATTENTION INSTALLER Disconnect all input power before beginning installation to prevent electrical shock and equipment...

Страница 2: ... prohibited TOC Table of Contents 1 General Description 3 2 Contents 3 a Package Contents 3 b Miscellaneous Parts 4 3 Dip Switch SW 2 6 position 4 4 AL Circuit Board 5 5 Installation Instructions 6 6 Apply Rail Assembly 7 7 Cylinder Installation 7 a Door Preparation 7 b Add or Remove Cylinder 8 c Installation and Orientation of Cylinder 8 8 Alarmed Exit 5300 Standard Operating Instructions 9 a Arm...

Страница 3: ...d for areas that require an alarm to sound upon exiting Once armed any push rail movement will activate the horn in the push rail The horn will continue to sound for two 2 minutes and shut off automatically The LED will flash indicating a violation has occurred Alarmed Exit Circuitry Figure 1 Manual dogging is provided standard on non fire rated devices 2 Contents a Package Contents 1 2 6 3 4 5 Fi...

Страница 4: ...ny is prohibited 2 Contents cont b Miscellaneous Parts Endcap MountingPlate Exit device chassis and rail assembly shown Chassis Assembly Cover Mounting rail insert Figure 3 3 Dip Switch SW 2 6 position Factory settings shown 1 DS 1 OFF DS 2 OFF REX Passage Delay set to 7 seconds 2 DS 3 OFF DS 4 OFF Automatic Alarm Reset set to 2 minutes 3 DS 5 ON Selects LED color Armed Green Violation Red Passage...

Страница 5: ...erved Reproduction in whole or in part without the express written permission of SARGENT Manufacturing Company is prohibited 4 AL Circuit Board Printed Circuit Board Figure 4 Note SW 1 Arm Disarm Switch shown in ON armed position Insert with circuit board Battery Figure 5 OFF ON 1 J3 J4 J2 J1 1 1 1 SW 2 6 position dip switch SW 1 Arm Disarm switch 6 5 4 3 2 1 Figure 6 ...

Страница 6: ...ich is designed for areas requiring field selectable time delay and automatic alarm reset options Verify hand and bevel of door Exit devices are always reverse bevel and are mounted on inside of door Left Hand Reverse Bevel Hinges Left Open Outward LHRB Inside View Outside View Inside View Outside View Right Hand Reverse Bevel Hinges Left Open Outward RHRB LHRB Shown RHRB Shown Figure 7 5 Installa...

Страница 7: ... plate tight against rail and attach to door with two 2 10 round head screws 6 Tighten all screws securely Figure 10 Figure 9 Lift Arm Level Mounting Plate Rail Assembly Rail Mounting Screw 2 Places 8 32 x 3 8 PH Truss HD Machine Screw Mounting Plate Mounting Plate Screws 10 24 x 3 4 PH RD HD Machine Screw Figure 10 Chassis Mounting Screws 1 4 20 x5 8 PH FL HD Machine Screws Four 4 places Figure 1...

Страница 8: ...ssion of SARGENT Manufacturing Company is prohibited 7 Cylinder Installation cont b Add or Remove Cylinder 3 Remove insert assembly from rail by sliding toward rail end Figure 13 c Installation and Orientation of Cylinder 1 Slide cylinder through collar into insert as shown 2 Note orientation of cylinder 3 Secure cylinder with cylinder nut tightening firmly 4 Operate cylinder and verify cam is ope...

Страница 9: ...seconds Signal above cylinder indicates unit is armed NOTE Unit is automatically armed 15 seconds after it is turned on Field selectable settings listed at bottom of page b Security Tamper Violation When ARMED depressing the push rail will activate alarm Horn will sound and red violation LED will flash The horn will continue to sound for two 2 minutes default After two 2 minutes unit will reset on...

Страница 10: ... seconds to indicate unit is armed Once armed depress push bar to sound alarm Rail alarm will sound until disarmed using one 1 of the following methods 1 Rail cylinder key 2 Automatic reset after optional field settable time delay of 2 5 or 10 minutes LED will flash red every 30 seconds to indicate rail has been violated and will continue to flash red until unit is reset manually If battery powere...

Страница 11: ... A8255A 08 19 1 800 727 5477 www sargentlock com Copyright 2019 SARGENT Manufacturing Company All rights reserved Reproduction in whole or in part without the express written permission of SARGENT Manufacturing Company is prohibited Page intentionally left blank ...

Страница 12: ...ew Haven CT 06511 USA 800 727 5477 www sargentlock com A8255A 08 19 Copyright 2019 SARGENT Manufacturing Company All rights reserved Reproduction in whole or in part without the express written permission of SARGENT Manufacturing Company is prohibited ...

Отзывы: